定制无凹槽骨干压配柄在肿瘤型大假体系统中的中期成功

Midterm Success of a Custom, Non-Fluted, Diaphyseal, Press-Fit Stem Used With a Tumor Megaprosthesis System.
PubMed 文献 · J Arthroplasty · 2019-12-31

结果显示所有柄均保留且无无菌性松动证据,17%出现轻度应力遮挡,植入物相关翻修均发生于翻修柄组。

要点

  • 无凹槽压配柄在肿瘤假体重建中中期无无菌性松动。
  • 17%出现轻度应力遮挡,但无柄翻修。
  • 翻修柄组植入物相关翻修率17%,定制柄组无。

核心结论

  • 无凹槽压配柄与肿瘤假体联合使用在中期的骨-假体界面稳定,无无菌性松动。

主要发现

  • 41柄中7柄(17%)因植入物相关并发症翻修,均为翻修柄(3例适配器失败,4例聚乙烯磨损)。
  • 末次随访所有柄均保留,无无菌性松动证据,7柄(17%)出现轻度应力遮挡。

关键数值与推荐

  • 影像学评估包括骨桥接、点焊接、骨吸收、下沉和基座形成。
  • 4例因局部复发或感染早期取柄,排除影像学分析。

临床怎么用

  • 对于肿瘤假体重建,可考虑使用无凹槽压配柄以降低无菌性松动风险。
  • 翻修柄组需关注适配器失败和聚乙烯磨损等并发症。

局限性

  • 随访时间中期,缺乏长期数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: High rates of aseptic loosening with cemented prostheses have led to increased utilization of uncemented stems in the setting of megaprosthetic reconstruction. Theoretic concerns of rotational instability resulted in early stem designs with de-rotational mechanisms such as flutes or side plates. However, these designs have their own associated complications, and mechanical data suggest they are unnecessary. The purpose of this study is to evaluate outcomes and survivorship of an unfluted diaphyseal press-fit stem in the setting of megaprosthetic reconstruction. METHODS: Forty-five patients (46 stems), with a minimum 3-year follow-up, underwent reconstruction using 1 of 2 fully porous coated, unfluted, press-fit stems between 2005 and 2013: revision stem with adapter to the megaprosthesis (revision stem), or custom megaprosthesis stem (custom stem). Complications were described using the Henderson classification system, and subanalyses evaluated stem-related failures and survival. Radiographic evaluation of stem fixation was determined via evidence of bone bridging, spot welding, resorption, subsidence, and pedestal formation. Four patients had early stem removal for local recurrence or infection and were thus excluded from the radiographic analyses. RESULTS: Twenty-eight femoral (15 revision stem, 13 custom stem) and 14 tibial (6 revision stem, 8 custom stem) stems were reviewed. Average follow-up was 81 months (range, 42-140 months). Revision for implant-related complications occurred in 7 of 41 (17%), all in revision stems (3 adapter failures, 4 polyethylene wear). At final follow-up, all stems were retained without evidence of aseptic loosening, although 7 of 41 (17%) exhibited mild stress shielding. CONCLUSION: A non-fluted, press-fit stem used with a tumor prosthesis provided a stable bone-prosthesis interface at midterm follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。