文献速递运动医学关节外科

肩袖缝合桥技术修复后1年内肌腱愈合的MRI信号强度进展及其与临床结局的相关性

Tendon Healing Progression Evaluated With Magnetic Resonance Imaging Signal Intensity and Its Correlation With Clinical Outcomes Within 1 Year After Rotator Cuff Repair With the Suture-Bridge Technique.
PubMed 文献 · Am J Sports Med · 2020-02-05

结果显示术后1个月VAS评分显著下降,6个月时功能评分均显著高于术前;远端信号/噪声商在9个月后降至正常,近端在6个月后降至正常;术后1-3个月近端信号/噪声商与VAS评分正相关、与功能评分负相关。

要点

  • 术后1个月疼痛显著改善,6个月时功能评分均显著高于术前。
  • 近端信号/噪声商在术后6个月降至正常,远端在9个月降至正常。
  • 术后1-3个月近端信号/噪声商越高,临床结局越差。

核心结论

  • 缝合桥技术肩袖修复后,MRI信号强度恢复至相对正常所需时间比临床显著改善所需时间更长。
  • 术后早期(1-3个月)近端肩袖肌腱信号强度越高与临床结局越差相关。

研究设计与样本

  • 前瞻性病例系列研究,证据等级4级。

主要发现

  • 术后1个月VAS评分较术前显著下降(P < .001)。
  • 术后6个月所有功能评分均显著高于术前(均P < .001)。
  • 远端信号/噪声商在术后1和3个月均显著高于正常(均P < .001),9个月后降至正常。
  • 近端信号/噪声商在术后1和3个月均显著高于正常(均P < .001),6个月后降至正常。
  • 术后1和3个月近端信号/噪声商与VAS评分正相关、与所有功能评分负相关;VAS >3的患者近端信号/噪声商高于VAS ≤3的患者(均P = .01)。

临床怎么用

  • 术后1-3个月近端肩袖肌腱MRI信号/噪声商升高可能提示临床结局较差,可作为早期评估参考。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: After a rotator cuff (RC) is repaired, its signal intensity (SI) on magnetic resonance imaging (MRI) gradually changes to normal and could reflect the degree of RC healing. Nevertheless, it remains unclear how long it takes for SI to recover to normal and whether the SI progression correlates with clinical outcomes after RC repair (RCR). PURPOSE: To serially evaluate the SIs of the repaired RC tendon on MRI and the postoperative clinical outcomes and then analyze the correlation between them. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: This study prospectively included 25 patients who underwent arthroscopic RCR with the suture-bridge technique between June 2016 and July 2017. Twenty-three patients accepted full follow-ups at 1, 3, 6, 9, and 12 months. Before surgery and at each follow-up, visual analog scale (VAS) for pain and 4 functional scores were evaluated: Constant-Murley score, American Shoulder and Elbow Surgeons shoulder evaluation form, modified University of California at Los Angeles score, and Fudan University shoulder score. The patients underwent MRI examinations at every follow-up. The values of the signal/noise quotient at the distal (SNQd) and proximal (SNQp) areas were calculated to evaluate the SI of the repaired tendon. The correlations of clinical outcomes with SNQd and SNQp values were analyzed, and subgroup analyses were performed. RESULTS: Overall, the mean postoperative VAS score significantly decreased at postoperative 1 month (P < .001), and the functional scores were all significantly higher than the preoperative values at 6 months (all P < .001). SNQd and SNQp values were both significantly higher than normal at 1 and 3 months (all P < .001) and reduced to normal after 9 and 6 months, respectively. Correlation analyses showed that the SNQp value significantly correlated with VAS score (positive) and all functional scores (negative) at 1 and 3 months postoperatively. Further comparison indicated that the patients with VAS score >3 had higher SNQp values than patients with VAS score ≤3 at 1 and 3 months postoperatively (both P = .01). CONCLUSION: After RCR with the suture-bridge technique, it took longer for SI to become relatively normal than it did to have a significant clinical improvement. Early after surgery (1-3 months), worse clinical outcome correlated with higher SI on proximal cuff tendon.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Liu S, Xie Y, Chen Q, et al. Tendon Healing Progression Evaluated With Magnetic Resonance Imaging Signal Intensity and Its Correlation With Clinical Outcomes Within 1 Year After Rotator Cuff Repair With the Suture-Bridge Technique. Am J Sports Med. 2020. PMID: 32023083. doi:10.1177/0363546519899357

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。