文献速递关节外科

直接前入路全髋关节置换术治疗重度发育性髋关节发育不良(Crowe III和IV型)的中长期疗效满意

The Direct Anterior Approach for Total Hip Arthroplasty for Severe Dysplasia (Crowe III and IV) Provides Satisfactory Medium to Long-Term Outcomes.
PubMed 文献 · J Arthroplasty · 2020-01-17

该回顾性队列研究评估了23例(29髋)因Crowe III-IV型发育性髋关节发育不良继发骨关节炎行直接前入路(DAA)全髋关节置换术(THA)并放置髋臼杯于真臼的患者。中位随访8.4±4.7年(范围2-20年),改良Harris髋关节评分从32±9改善至94±7,WOMAC从46±18改善至90±7,Oxford髋关节评分为56±4,患者满意度高(非常满意90%,满意10%),无脱位或感染。结论认为DAA联合真臼放置髋臼杯可提供满意的中长期临床和影像学结果。

要点

  • DAA联合真臼放置髋臼杯治疗Crowe III-IV型DDH继发骨关节炎的中长期临床和影像学结果满意。
  • 改良Harris髋关节评分从32±9改善至94±7,WOMAC从46±18改善至90±7。
  • 无脱位或感染,3髋因磨损性松动行翻修,2髋因并发症行非假体移除再手术。

核心结论

  • DAA联合真臼放置髋臼杯治疗重度发育性髋关节发育不良(Crowe III-IV型)的中长期临床和影像学结果与其他入路相比满意。

研究设计与样本

  • 回顾性队列研究(证据等级IV),纳入23例连续患者(29髋)因Crowe III-IV型发育性髋关节发育不良继发骨关节炎行DAA全髋关节置换术,髋臼杯放置于真臼,手术在牵引床上进行,随访至少2年。

主要发现

  • 1例患者(2髋)带原假体死亡(术后13年和14年),3例患者(3髋)因磨损性松动行翻修(术后14、16、18年),无脱位或感染。
  • 剩余19例患者(24髋)在8.4±4.7年(范围2-20年)时评估,2例患者(2髋)出现需再手术但不移除假体的并发症。
  • 改良Harris髋关节评分从32±9改善至94±7,WOMAC从46±18改善至90±7,Oxford髋关节评分为56±4。
  • 患者非常满意占90%,满意占10%;下肢长度差异为2.5±9.0 mm。

临床怎么用

  • 对于Crowe III-IV型发育性髋关节发育不良继发骨关节炎患者,DAA全髋关节置换术联合真臼放置髋臼杯可获得满意的中长期临床和影像学结果。

局限性

  • 本研究为回顾性队列研究,证据等级IV,样本量较小(23例患者,29髋)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The direct anterior approach (DAA) is increasingly used for total hip arthroplasty (THA). Although the DAA can reduce pain, recovery time, and dislocations in nondysplastic hips, few studies report its results in patients with severe dysplasia. We aimed to evaluate outcomes of primary THA through the DAA with cup placement at the true acetabulum in hips with severe dysplasia. METHODS: We retrospectively evaluated 23 consecutive patients (29 hips) who underwent THA by DAA for osteoarthritis secondary to Crowe III-IV dysplasia. Surgical procedures were performed on a traction table, and the acetabular cup was placed in the true acetabulum. Patients were assessed clinically (complications, modified Harris Hip Score, Western Ontario and McMaster Universities Osteoarthritis Index, Oxford Hip Score) and radiographically (radiolucencies, subsidence, leg length discrepancies, cup inclination, and cup coverage) at a minimum of 2 years. RESULTS: One patient (2 hips) died with original implants (at 13 and 14 years), 3 patients (3 hips) were revised due to wear-induced loosening (at 14, 16, and 18 years), and there were no dislocations or infections. The remaining 19 patients (24 hips) were assessed at 8.4 ± 4.7 years (range 2-20); 2 patients (2 hips) had complications that required reoperation without implant removal. The modified Harris Hip Score improved from 32 ± 9 to 94 ± 7, Western Ontario and McMaster Universities Osteoarthritis Index from 46 ± 18 to 90 ± 7, and Oxford Hip Score was 56 ± 4. Patients were very satisfied (90%) or satisfied (10%). Limb length discrepancy was 2.5 ± 9.0 mm. CONCLUSION: THA through the DAA with cup placement at the true acetabulum provides satisfactory mid to long-term clinical and radiographic outcomes compared to other approaches for hips with severe dysplasia. LEVEL OF EVIDENCE: Level IV, retrospective cohort study.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Viamont-Guerra MR, Chen AF, Stirling P, et al. The Direct Anterior Approach for Total Hip Arthroplasty for Severe Dysplasia (Crowe III and IV) Provides Satisfactory Medium to Long-Term Outcomes. J Arthroplasty. 2020. PMID: 32046871. doi:10.1016/j.arth.2020.01.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。