单问题与多问题患者报告结局测量在全髋关节置换术后的性能比较
结果显示M-SANE与HOOS-Jr和PROMIS-10生理组分呈中至强相关,地板和天花板效应与HOOS-Jr相当,反应性不劣于HOOS-Jr且优于PROMIS-10生理组分。
要点
- M-SANE单问题量表与HOOS-Jr和PROMIS-10生理组分在THA术后1年呈中至强相关。
- M-SANE的地板和天花板效应与HOOS-Jr相当。
- M-SANE的反应性(SRM=1.06)与HOOS-Jr相当(SRM=1.33)且优于PROMIS-10生理组分(SRM=0.65)。
核心结论
- M-SANE在评估全髋关节置换术后纵向患者报告结局方面,多项心理测量学性能与更繁琐的PROMs相似。
研究设计与样本
- M-SANE要求患者在0到10分之间评估髋关节,10分为最佳可能评分。
- 效度通过Spearman相关性和地板及天花板效应确定,反应性通过标准化反应均值(SRM)分析。
主要发现
- M-SANE平均评分从术前3.3改善至术后1年7.1。
- 术后1年M-SANE与HOOS-Jr呈中度至强相关(ρ=0.75,P<.001),与PROMIS-10生理组分总结呈中度至强相关(ρ=0.63,P<.001)。
- M-SANE的地板效应为2.0%、天花板效应为21.3%,与HOOS-Jr(地板0.0%、天花板20.8%)相当。
- M-SANE术后反应性(SRM=1.06,95%CI:0.79-1.33)与HOOS-Jr(SRM=1.33,95%CI:1.08-1.59)相当,且优于PROMIS-10生理组分总结(SRM=0.65,95%CI:0.55-0.74)。
临床怎么用
- M-SANE可作为全髋关节置换术后纵向患者报告结局的简化评估工具,减轻患者填写负担。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Several patient-reported outcome measures (PROMs) exist to measure outcomes after total hip arthroplasty (THA) but can be limited by patient-perceived burden and completion rates. We analyzed whether the modified single assessment numerical evaluation (M-SANE), a one-question PROM, would perform similarly to multiple-question PROMs among patients undergoing primary THA. METHODS: Patients undergoing THA completed the Patient-Reported Outcomes Measurement Information System-10 (PROMIS-10), the Hip Disability and Osteoarthritis Outcomes Score Junior (HOOS-Jr), and M-SANE questionnaires both preoperatively and postoperatively. The M-SANE assessment asked patients to assess their hip on a scale from 0 to 10, with 10 being the best possible score. Validity of M-SANE compared with other PROMs was determined by Spearman's correlation and floor and ceiling effects. Responsiveness was analyzed using standardized response mean (SRM). RESULTS: One hundred and thirty six patients with at least 1-year follow-up were reviewed. The average M-SANE score improved from 3.3 preoperatively to 7.1 at one year postoperatively. There was moderate to strong correlation at one-year follow-up between the M-SANE and HOOS-Jr (ρ = 0.75, P < .001) and PROMIS-10 physical component summary (ρ = 0.63, P < .001). Floor and ceiling effects of the M-SANE (floor 2.0%, ceiling 21.3%) were comparable to the HOOS-Jr (floor 0.0%, ceiling 20.8%). The responsiveness of the M-SANE after THA (SRM = 1.06, 95% CI: 0.79-1.33) was comparable to HOOS-Jr (SRM = 1.33, 95% CI: 1.08-1.59) and superior to PROMIS-10 physical component summary (SRM = 0.65, 95% CI: 0.55-0.74). CONCLUSION: The M-SANE has performed similarly across multiple psychometric properties compared with more burdensome PROMs in assessing longitudinal patient-reported outcomes after THA.
引用
- Torchia MT, Austin DC, Werth PM, et al. A SANE Approach to Outcome Collection? Comparing the Performance of Single- Versus Multiple-Question Patient-Reported Outcome Measures After Total Hip Arthroplasty. J Arthroplasty. 2020. PMID: 32008770. doi:10.1016/j.arth.2020.01.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。