文献速递关节外科

机器人全膝关节置换中通过假体定位平衡屈曲间隙及其与传统解剖旋转标志的关系

Flexion Space Balancing Through Component Positioning and Its Relationship to Traditional Anatomic Rotational Landmarks in Robotic Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2020-01-24

本研究评估233例机器人辅助全膝关节置换患者,术前CT建立自体经上髁轴(TEA)和后髁角(PCA),股骨假体旋转以匹配自体滑车和内侧股骨髁来设定屈曲间隙。结果显示术中测量的内侧屈曲间隙与假体相对TEA或PCA的关系无显著相关;

要点

  • 术中屈曲间隙平衡与假体相对TEA或PCA的关系无显著相关。
  • 内翻膝中术前机械轴对齐与假体相对TEA和PCA的外旋正相关。
  • 外翻膝中术前股骨远端外侧角仅与假体相对PCA的关系正相关。

核心结论

  • 通过股骨假体定位实现的术中屈曲间隙平衡与假体相对自体TEA或PCA的关系无显著相关。

研究设计与样本

  • 评估233例接受机器人臂辅助全膝关节置换的患者,术前CT建立自体TEA和PCA。

主要发现

  • 术中测量的内侧屈曲间隙与假体相对PCA或TEA的关系在内翻或外翻膝中均无显著相关。

临床怎么用

  • 机器人全膝关节置换中可依据自体滑车和内侧股骨髁设定股骨假体旋转以平衡屈曲间隙。
  • 内翻膝患者术前机械轴对齐程度可提示假体相对TEA和PCA的外旋增加。
  • 外翻膝患者术前股骨远端外侧角程度可提示假体相对PCA的旋转关系。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The use of the femoral component position to balance the flexion space and its relationship to the transepicondylar axis (TEA) and posterior condylar angle (PCA) has not been thoroughly evaluated. METHODS: A total of 233 patients undergoing robotic arm-assisted total knee arthroplasty were evaluated. Native TEA and PCA were established on preoperative computed tomography scans. Femoral component rotation was set in the axial plane to match the native trochlea and native medial femoral condyle to set the flexion gap. Knee flexion space gaps and component position were recorded. The relationship of the femoral component to the native TEA, PCA, and preoperative radiographic landmarks was evaluated. RESULTS: The intraoperative measured medial flexion space gap did not significantly correlate with the relationship of the femoral component to the PCA or TEA in varus or valgus knees. In varus knees, the preoperative mechanical axis alignment had a positive relationship to femoral component position when compared to the PCA (P = .04) and TEA (P = .002). In valgus knees, there was a positive correlation between the preoperative lateral distal femoral angle and component position when compared to the PCA (P = .04) only. CONCLUSION: Intraoperative measured flexion space balance through femoral component positioning did not correlate with its relationship to the native TEA or PCA. In varus knees, the preoperative mechanical axis alignment correlated with an increase in femoral component external rotation to the TEA and PCA. In valgus knees, the severity of preoperative lateral distal femoral angle correlated with the rotational relationship of the femoral component to the PCA only.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Nodzo SR, Staub TM, Jancuska JM, et al. Flexion Space Balancing Through Component Positioning and Its Relationship to Traditional Anatomic Rotational Landmarks in Robotic Total Knee Arthroplasty. J Arthroplasty. 2020. PMID: 32057599. doi:10.1016/j.arth.2020.01.051

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。