文献速递关节外科

血清D-二聚体诊断髋膝关节翻修术后假体周围感染的准确性

The Utility of Serum d-Dimer for the Diagnosis of Periprosthetic Joint Infection in Revision Total Hip and Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2020-01-23

本研究回顾性分析172例翻修THA/TKA手术,其中111例符合2013 ICM标准纳入分析,评估血清D-二聚体(阈值850 ng/mL)诊断假体周围感染的准确性。结果显示D-二聚体敏感性高(95.9%)但特异性低(32.3%),总体准确性差(61%),AUC为0.742。

要点

  • 血清D-二聚体诊断PJI敏感性高(95.9%)但特异性低(32.3%)。
  • 以850 ng/mL为阈值,总体准确性仅61%,阳性预测值52.8%。
  • D-二聚体不能单独用于翻修THA/TKA中区分感染与无菌性失败。

核心结论

  • 在翻修THA和TKA中,以850 ng/mL为阈值,血清D-二聚体区分感染与无菌病例的准确性差。

研究设计与样本

  • 回顾性分析单中心3名专科医生于2017年8月至2019年5月实施的172例翻修THA/TKA连续病例,其中111例(42例THA/69例TKA)具有完整2013 ICM标准检测并纳入最终分析。

主要发现

  • 与2013 ICM标准比较,D-二聚体敏感性95.9%、阴性预测值90.9%、特异性32.3%、阳性预测值52.8%、总体准确性61%。
  • 阳性似然比1.42,阴性似然比0.13,AUC为0.742。
  • 感染组与无菌组基线 demographics 无统计学显著差异。

关键数值与推荐

  • 采用2013国际共识会议(ICM)标准作为金标准定义感染与无菌翻修。
  • 血清D-二聚体阈值设为850 ng/mL。

临床怎么用

  • 血清D-二聚体不宜单独用于翻修THA/TKA中排除或确认假体周围感染。
  • 高敏感性提示阴性结果对排除PJI有一定价值,但低特异性限制其阳性诊断意义。

局限性

  • 回顾性单中心研究,样本量有限(最终分析111例)。
  • 仅评估单一阈值850 ng/mL,未探索其他阈值。
  • 部分病例因缺乏完整2013 ICM标准检测被排除。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is scarce and contradicting evidence supporting the use of serum d-dimer for the diagnosis of periprosthetic joint infection in revision total hip (THA) and knee (TKA) arthroplasty. Therefore, the purpose of this study is to test the accuracy of serum d-dimer against the 2013 International Consensus Meeting (ICM) criteria. METHODS: A retrospective review was performed on a consecutive series of 172 revision THA/TKA surgeries performed by 3 fellowship-trained surgeons at a single institution (August 2017 to May 2019) and that had d-dimer performed during their preoperative workup. Of this cohort, 111 (42 THAs/69 TKAs) cases had complete 2013 ICM criteria tests and were included in the final analysis. Septic and aseptic revisions were categorized per 2013 ICM criteria ("gold standard") and compared against serum d-dimer using an established threshold (850 ng/mL). Sensitivity, specificity, likelihood ratios, and positive/negative predictive values were determined. Independent t-tests, Fisher's exact tests, chi-squared tests, and receiver operating characteristic curve analysis were performed. RESULTS: There was no statistically significant difference in baseline demographics between septic and aseptic cases per 2013 ICM criteria. When compared to ICM criteria, d-dimer demonstrated high sensitivity (95.9%) and negative predictive value (90.9%) but low specificity (32.3%), positive predictive value (52.8%), and overall, poor accuracy (61%) to diagnose periprosthetic joint infection. Positive likelihood ratio was 1.42 while negative likelihood ratio was 0.13. The area under the curve (AUC) was 0.742. CONCLUSION: Serum d-dimer has poor accuracy to discriminate between septic and aseptic cases using a described threshold in the setting of revision THA and TKA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Pannu TS, Villa JM, Patel PD, et al. The Utility of Serum d-Dimer for the Diagnosis of Periprosthetic Joint Infection in Revision Total Hip and Knee Arthroplasty. J Arthroplasty. 2020. PMID: 32061477. doi:10.1016/j.arth.2020.01.034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。