测量肩胛盂版本的Ellipse改良Friedman法
本研究回顾性分析100例初次全肩关节置换术患者的CT扫描,比较Friedman法与Ellipse法测量肩胛盂版本。Friedman法平均版本为-3.11°,Ellipse法为-1.95°(p=0.002),16例差异大于5°;Ellipse法观察者间与观察者内一致性均优秀,推荐在测量肩胛盂版本前使用Ellipse法定义盂中点。
要点
- Ellipse法测量肩胛盂版本与Friedman法差异有统计学意义(p=0.002)。
- 16例患者两种方法差异大于5°,被认为具有临床意义。
- Ellipse法观察者间一致性优秀,观察者内重复性系数为0.94。
核心结论
- 推荐在测量肩胛盂版本前使用Ellipse改良法定义盂中点。
研究设计与样本
- 回顾性研究,评估100例接受初次全肩关节置换术患者的CT扫描。
- 由两名资深观察者分别使用Friedman法和Ellipse法测量肩胛盂版本。
- 采用配对t检验分析显著性,Bland-Altman图评估一致性。
主要发现
- Friedman法平均肩胛盂版本为-3.11°(范围-23.8°至17.9°)。
- Ellipse法平均肩胛盂版本为-1.95°(范围-29.8°至24.6°)。
- 两种方法差异有统计学意义(p=0.002)。
- 16例患者两种方法差异大于5°,被认为具有临床意义。
- 两种方法一致性差,95%一致性界限相对较大;Ellipse法观察者间一致性优秀,观察者内重复性系数为0.94。
关键数值与推荐
- 两种方法差异大于5°被认为具有临床意义。
- Ellipse法观察者内重复性系数为0.94。
临床怎么用
- 在全肩关节置换术前测量肩胛盂版本时,可先使用Ellipse法定义盂中点再测量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the 'classic' Friedman method. METHODS: This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary TSA. The glenoid version was measured using the Friedman and Ellipse methods by two senior observers. Statistical analyses were performed using the paired t-test for significance and the Bland-Altman plot for agreement. RESULTS: The mean glenoid version was -3.11° (-23.8° to 17.9°) using the Friedman method and -1.95° (-29.8° to 24.6°) using the Ellipse method (p = 0.002). In 16 patients the difference between methods was greater than 5°, which we considered to be clinically significant. There was poor agreement between methods with relatively large 95% limits of agreement. There was excellent inter-rater agreement between the observers for the Ellipse method and similarly, the intrarater agreement was excellent with a repeatability coefficient of 0.94. CONCLUSION: We recommend the use of the Ellipse modification to define the mid glenoid point prior to measuring the glenoid version in patients undergoing TSA. Cite this article: Bone Joint J 2020;102-B(2):232-238.
引用
- Javed S, Hadi S, Imam MA, et al. The Ellipse modification of the Friedman method for measuring glenoid version. Bone Joint J. 2020. PMID: 32009429. doi:10.1302/0301-620X.102B2.BJJ-2019-0726.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。