股骨翻修中模块化与一体式带齿锥形钛柄的比较
该回顾性研究比较了145例股骨翻修中模块化与一体式带齿锥形钛柄的疗效,平均随访5.12年。结果显示两组在再手术率、骨折、脱位、无菌性松动、下沉、偏心距恢复及Harris髋关节评分方面均无统计学显著差异。
要点
- 模块化与一体式带齿锥形钛柄在股骨翻修中并发症率相当。
- 两组功能结局与影像学参数(下沉、偏心距、腿长差异)无显著差异。
- 模块化对更复杂股骨骨缺损的益处尚需进一步研究。
核心结论
- 模块化与一体式带齿锥形钛柄在股骨翻修中显示出相当的并发症率、功能结局和影像学参数。
研究设计与样本
- 回顾性综述145例股骨翻修,最低随访2年(平均5.12年,范围2-17.3年),模块化组67例,一体式组78例。
临床怎么用
- 对于股骨翻修,模块化和一体式带齿锥形钛柄均可作为选择,两者并发症和功能结局相当。
- 在复杂股骨骨缺损(IIIB或IV级)中,一体式柄使用例数有限,模块化的优势需进一步研究。
局限性
- 回顾性研究设计。
- 接受一体式柄的IIIB或IV级股骨骨缺损患者数量有限。
- 需要未来研究确定模块化对更复杂股骨缺损是否有益。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Proposed benefits of modularity for femoral revisions in total hip arthroplasty (THA) include more precise biomechanical restoration and improved stability, but this has not been proven with use of a splined, tapered design. This study's purpose is to compare (1) complication rates, (2) functional outcomes, and (3) radiographic measures of subsidence, offset, and leg length discrepancy with the use of modular vs monoblock splined, tapered titanium stems in revision THA. METHODS: We retrospectively reviewed 145 femoral revisions with minimum 2-year follow-up (mean, 5.12 years; range, 2-17.3 years). Patients receiving a modular (67) or monoblock (78) splined, tapered titanium stem for femoral revision were included. RESULTS: There were no statistically significant differences in rates of reoperation (22.3% vs 17.9%; P = .66), intraoperative fracture (9.0% vs 3.8%; P = .30), postoperative fracture (3.0% vs 1.3%; P = .47), dislocation (11.9% vs 5.1%; P = .23), or aseptic loosening (4.5% vs 6.4%; P = .73) between the modular and monoblock cohorts, respectively. There were similar results regarding subsidence >5 mm (10.4% vs 12.8%; P = .22), LLD >1 cm (35.8% vs 38.5%; P = .74), restoration of hip offset (-5.88 ± 10.1 mm vs -5.07 ± 12.1 mm; P = .67), and Harris Hip Score (70.7 ± 17.9 vs 73.9 ± 19.7; P = .36) between groups. Multivariate regression showed no differences in complications (P = .44) or reoperations (P = .20) between groups. CONCLUSION: Modular and monoblock splined, tapered titanium stems demonstrated comparable complication rates, functional outcomes, and radiographic parameters for femoral revisions. However, a limited number of patients with grade IIIB or IV femoral bone loss received a monoblock stem. Future investigations are required to determine whether modularity is beneficial for more complex femoral defects.
引用
- Cohn MR, Tetreault MW, Li J, et al. Is There a Benefit to Modularity for Femoral Revisions When Using a Splined, Tapered Titanium Stem? J Arthroplasty. 2020. PMID: 32067894. doi:10.1016/j.arth.2019.12.041
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。