REDAPT一体式锥形开槽喷砂锻造钛翻修股骨柄的短期结果
多中心回顾性研究纳入157髋(153例),评估REDAPT一体式锥形开槽喷砂锻造钛翻修股骨柄的短期效果。平均随访11.6个月,术中并发症4.9%,一年内再翻修3.7%,平均下沉1.64 mm,>5 mm下沉占11.8%,>10 mm占2.1%。作者认为设计改进可减轻早期下沉和脱位担忧。
要点
- 术中并发症4.9%,其中6例为术中骨折,均未发生在柄打入过程中。
- 一年内再翻修率3.7%,仅1例因感染取出假体。
- 平均下沉1.64 mm,>5 mm下沉11.8%,>10 mm下沉2.1%。
核心结论
- REDAPT一体式锥形开槽喷砂锻造钛翻修股骨柄的短期下沉和再翻修率可接受,是股骨翻修的有价值选择。
研究设计与样本
- 多机构回顾性研究,纳入连续接受该一体式锥形开槽钛柄的初次或翻修全髋关节置换患者,由四家机构的八名关节置换专科医生手术,共157髋(153例),平均随访11.6个月(SD 7.8)。
主要发现
- 术中并发症8例(4.9%),其中6例为术中骨折,均未发生在柄打入过程中。
- 一年内再翻修6髋(3.7%),仅1例因感染取出假体。
- 末次随访平均总下沉1.64 mm(SD 2.47);可测量144柄中,17柄(11.8%)下沉>5 mm,3柄(2.1%)下沉>10 mm。
- 单因素回归分析显示三个月后额外下沉极小。
- 多因素回归分析显示下沉与假体周围骨折作为手术指征、扩展转子截骨(ETO)、Paprosky股骨骨缺损分型、柄长度或手术类型(全翻修 vs 转换/初次)均无显著关联。
临床怎么用
- 对于需股骨翻修的病例,可考虑使用该一体式锥形开槽钛柄,其短期下沉和再翻修风险较低。
- 术中注意防范术中骨折,尽管本研究显示骨折未发生在柄打入过程中。
- 术后三个月内需关注下沉,三个月后额外下沉通常极小。
局限性
- 回顾性研究设计,随访时间短(平均11.6个月),缺乏长期结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Although good clinical outcomes have been reported for monolithic tapered, fluted, titanium stems (TFTS), early results showed high rates of subsidence. Advances in stem design may mitigate these concerns. This study reports on the use of a current monolithic TFTS for a variety of indications. METHODS: A multi-institutional retrospective study of all consecutive total hip arthroplasty (THA) and revision total hip arthroplasty (rTHA) patients who received the monolithic TFTS was conducted. Surgery was performed by eight fellowship-trained arthroplasty surgeons at four institutions. A total of 157 hips in 153 patients at a mean follow-up of 11.6 months (SD7.8) were included. Mean patient age at the time of surgery was 67.4 years (SD 13.3) and mean body mass index (BMI) was 28.9 kg/m2 (SD 6.5). Outcomes included intraoperative complications, one-year all-cause re-revisions, and subsidence at postoperative time intervals (two weeks, six weeks, six months, nine months, and one year). RESULTS: There were eight intraoperative complications (4.9%), six of which were intraoperative fractures; none occurred during stem insertion. Six hips (3.7%) underwent re-revision within one year; only one procedure involved removal of the prosthesis due to infection. Mean total subsidence at latest follow-up was 1.64 mm (SD 2.47). Overall, 17 of 144 stems (11.8%) on which measurements could be performed had >5 mm of subsidence, and 3/144 (2.1%) had >10 mm of subsidence within one year. A univariate regression analysis found that additional subsidence after three months was minimal. A multivariate regression analysis found that subsidence was not significantly associated with periprosthetic fracture as an indication for surgery, the presence of an extended trochanteric osteotomy (ETO), Paprosky classification of femoral bone loss, stem length, or type of procedure performed (i.e. full revision vs conversion/primary). CONCLUSION: Advances in implant design, improved trials, a range of stem lengths and diameters, and high offset options mitigate concerns of early subsidence and dislocation with monolithic TFTS, making them a valuable option for femoral revision. Cite this article: Bone Joint J 2020;102-B(2):191-197.
引用
- Gabor JA, Padilla JA, Feng JE, et al. Short-term outcomes with the REDAPT monolithic, tapered, fluted, grit-blasted, forged titanium revision femoral stem. Bone Joint J. 2020. PMID: 32009430. doi:10.1302/0301-620X.102B2.BJJ-2019-0743.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。