高孔隙率钛髋臼组件在全髋置换中的系统综述
该系统综述纳入16项研究共11,366例,评估高孔隙率钛髋臼杯在初次和翻修全髋关节置换中的表现。初次置换生存率99.3%,无菌性松动率0.1%;翻修生存率93.5%,无菌性松动率2.1%。短期至中期随访结果满意,未见髋臼杯移位或透亮线证据。
要点
- 初次全髋置换中高孔隙率钛髋臼杯生存率99.3%,无菌性松动率0.1%。
- 翻修全髋置换中生存率93.5%,无菌性松动率2.1%。
- 短期至中期随访未见髋臼杯移位或透亮线证据。
核心结论
- 中等质量证据表明高孔隙率钛髋臼组件在初次和翻修全髋置换中短期至中期临床结果满意,未显示髋臼杯移位或透亮线证据。
- 目前尚无关于这些组件长期生存率的证据,需要更高质量研究比较其与常规钛髋臼植入物的长期寿命。
研究设计与样本
- 系统综述,检索US National Library of Medicine(PubMed/MEDLINE)、Embase和Cochrane系统综述数据库。
- 检索关键词包括「tritanium」或「highly-porous」与「titanium」或「acetabular」与「trabecular」与「titanium」。
- 共纳入16项研究,11,366例,60%为女性,平均随访2-7年。
主要发现
- 初次全髋置换中高孔隙率钛髋臼组件总生存率为99.3%(10,886例中10,811例)。
- 初次全髋置换中无菌性松动率为0.1%。
- 翻修全髋置换中高孔隙率钛髋臼组件总生存率为93.5%(480例中449例)。
- 翻修全髋置换中无菌性松动率为2.1%。
临床怎么用
- 在初次和翻修全髋置换中可考虑使用高孔隙率钛髋臼组件,短期至中期生存率和无菌性松动率表现满意。
- 需注意目前缺乏长期生存率证据,应关注远期随访以评估髋臼植入物寿命。
局限性
- 纳入研究的平均随访仅2-7年,无长期生存率证据。
- 作者认为需要更高质量研究以生成关于高孔隙率钛髋臼植入物长期寿命的更多循证结论。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A number of papers have been published reporting on the clinical performance of highly porous coated titanium acetabular cups in primary and revision total hip arthroplasty (THA). However, no systematic review of the literature has been published to date. METHODS: The US National Library of Medicine (PubMed/MEDLINE), Embase, and the Cochrane Database of Systematic Reviews were queried for publications utilizing the following keywords: "tritanium" OR "highly-porous" AND "titanium" OR "acetabular" AND "trabecular" AND "titanium". RESULTS: Overall, 16 studies were included in this review (11,366 cases; 60% females, 2-7 years mean follow-up). The overall survival rate of highly porous titanium acetabular components in primary cases was 99.3% (10,811 of 10,886 cases), whereas the rate of aseptic loosening was 0.1%. The overall survival rate of the highly porous titanium acetabular components in revision THA cases was 93.5% (449 of 480 cases), whereas the rate of aseptic loosening was 2.1%. CONCLUSION: There was moderate quality evidence to show that the use of highly porous titanium acetabular components in primary and revision THA cases is associated with satisfactory clinical outcomes in the short- and medium-term, without showing any evidence of cup migration or radiolucency. Taking into consideration that there is no evidence yet regarding the long-term survivorship of these components, we feel that further research of higher quality is required to generate more evidence-based conclusions regarding the longevity of highly porous titanium acetabular implants compared with conventional titanium counterparts.
引用
- Malahias MA, Kostretzis L, Greenberg A, et al. Highly Porous Titanium Acetabular Components in Primary and Revision Total Hip Arthroplasty: A Systematic Review. J Arthroplasty. 2020. PMID: 32070658. doi:10.1016/j.arth.2020.01.052
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。