文献速递关节外科创伤骨科骨肿瘤

旋转铰链全膝关节与股骨远端置换系统的适应证、生存率与临床结局

Indications, Survivorship, and Clinical Outcomes of a Rotating Hinge Total Knee and Distal Femoral Arthroplasty System.
PubMed 文献 · J Arthroplasty · 2019-12-19

BACKGROUND: Rotating hinge knee prostheses (with or without distal femoral replacement) are indicated in cases of unreconstructible bony or soft tissue compromise. Despite their versatility, these implants have demonstrated high rates of mechanical failure.…

要点

  • 旋转铰链全膝组无无菌性松动翻修,股骨远端置换组仅1例无菌性松动翻修。
  • 早期翻修主要原因倾向于感染,而非机械失败。
  • 术后SF-12生理 Component、WOMAC和KSS评分分别为30.12±10.17、55.90±21.51和115.62±45.20。

核心结论

  • 该新型铰链膝关节系统是复杂和翻修膝关节置换的高度耐久选择,早期失败倾向于继发于感染,仅观察到1例无菌性松动,但需持续随访确定长期预后。

主要发现

  • 旋转铰链组6例翻修,无因无菌性松动翻修;股骨远端置换组5例翻修,其中1例因无菌性松动翻修。
  • 平均随访2.89±2.09年,术后SF-12生理成分评分30.12±10.17,WOMAC评分55.90±21.51,KSS评分115.62±45.20。
  • 手术适应证多样,旋转铰链全膝最常见为二期再植入,股骨远端置换最常见为骨折。

临床怎么用

  • 对于骨或软组织严重缺损无法重建的复杂或翻修膝关节病例,可考虑使用该新型铰链膝关节系统,但需警惕感染导致的早期失败。

局限性

  • 平均随访仅2.89±2.09年,无法确定长期预后;为单中心单制造商器械的回顾性分析,样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Rotating hinge knee prostheses (with or without distal femoral replacement) are indicated in cases of unreconstructible bony or soft tissue compromise. Despite their versatility, these implants have demonstrated high rates of mechanical failure. We aimed to review clinical outcomes of a novel hinged knee arthroplasty system. METHODS: We reviewed all cases in a prospective database of hinged total knee arthroplasty (with and without distal femoral arthroplasty) involving a single manufacturer's implant system at a large tertiary-level academic health sciences center. We collected reasons for surgery, implant survivorship, reasons for revision, and clinical outcomes (Short Form 12, Western Ontario and McMaster Universities Osteoarthritis Index, and Knee Society Scores). RESULTS: Seventy-six cases of hinged knee implants using the knee system under investigation were performed (39 hinged total knee and 37 distal femoral replacements) between 2011 and 2018, inclusive. Indications for surgery varied, with second-stage reimplantation most common for rotating hinge and fracture most common for distal femoral arthroplasty. There were 6 revisions in the rotating hinge group (none for aseptic loosening) and 5 in the distal femoral arthroplasty group (1 for aseptic loosening). Average follow-up was 2.89 ± 2.09 years. Postoperative Short Form 12 (Physical Component), Western Ontario and McMaster Universities Osteoarthritis Index, and Knee Society Scores were 30.12 ± 10.17, 55.90 ± 21.51, and 115.62 ± 45.20, respectively. CONCLUSION: This novel hinged knee system is a highly durable option for complex and revision knee arthroplasty. Early failures tend to be secondary to infection. We observed only a single case of aseptic loosening. Although these early results are encouraging, ongoing follow-up is required to determine long-term prognosis in patients receiving this implant.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Chaudhry H, MacDonald SJ, Howard JL, et al. Indications, Survivorship, and Clinical Outcomes of a Rotating Hinge Total Knee and Distal Femoral Arthroplasty System. J Arthroplasty. 2019. PMID: 31911095. doi:10.1016/j.arth.2019.12.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。