直接前入路联合重建笼与打压植骨行髋臼翻修的中期随访
本研究回顾64例(64髋)严重髋臼骨缺损患者,经直接前入路(DAA)使用重建笼与打压植骨行髋臼杯翻修,其中22例同时翻修股骨柄。中位随访27.6个月时6例再翻修(假体失败、感染、复发性脱位各2例),1髋影像学失败但无症状未翻修,WOMAC评分较术前显著改善(P < .01)。结论认为DAA下该技术可获得良好中期疗效,并发症在预期范围内且脱位率低。
要点
- DAA联合重建笼与打压植骨可用于严重髋臼骨缺损的翻修。
- 64例中6例再翻修,脱位率低,并发症在预期范围内。
- WOMAC评分较术前显著改善(P < .01),中期疗效良好。
核心结论
- 经DAA使用重建笼与打压植骨处理严重髋臼骨缺损的髋臼杯翻修,可获得良好中期临床与影像学结果。
研究设计与样本
- 回顾性病例系列,纳入64例(64髋)严重髋臼骨缺损行髋臼杯翻修患者,均经DAA使用重建笼与打压植骨,其中22例同时翻修股骨柄。
主要发现
- 平均随访27.6个月(范围11-84个月)时,64例中6例再翻修,假体失败、感染、复发性脱位各2例。
- 1髋出现假体影像学失败,但患者无症状且未再翻修。
- 队列整体WOMAC评分中位数较术前显著改善(P < .01)。
临床怎么用
- 对严重髋臼骨缺损的翻修病例,可考虑经DAA联合重建笼与打压植骨重建髋臼。
- 该技术中期并发症在预期范围内且脱位率低,但仍需监测假体失败、感染与脱位。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Severe acetabular bone loss is often treated with reconstruction cages and impaction grafting using allograft bone. Accurate implant positioning is crucial for successful clinical and radiological outcomes. The direct anterior approach (DAA) is a standard approach for primary total hip arthroplasty (THA) that is being used more frequently for revision THA. The aim of this study was to report midterm clinical and radiological outcomes of acetabular revision arthroplasty using the DAA to address large acetabular defects by using a reconstruction cage and impaction grafting. METHODS: Acetabular cup revisions were performed in 64 patients (64 hips) with severe acetabular bone loss. All patients received reconstruction cages with impaction grafting via the DAA. The stem was also revised in 22 patients. Complications, radiological, and functional outcomes were assessed. RESULTS: Six of the 64 patients were revised at a mean follow-up of 27.6 months (range, 11-84 months), two each for implant failure, infection, and recurrent dislocation. One hip showed the radiological failure of the implant, but the patient was asymptomatic and was not revised. The median Western Ontario McMasters Osteoarthritis Score (WOMAC) for the cohort overall improved significantly (P < .01) by the latest follow-up compared with preoperative scores. CONCLUSION: Good midterm outcomes can be obtained with the DAA for acetabular cup revisions done to address severe acetabular bone loss by using reconstruction cages and impaction grafting. The number of complications was within the expected range for this type of revision procedure at midterm follow-up, and dislocation rates were low.
引用
- Thaler M, Dammerer D, Leitner H, et al. Mid-term Follow-up of the Direct Anterior Approach in Acetabular Revision Hip Arthroplasty Using a Reconstruction Cage With Impaction Grafting. J Arthroplasty. 2020. PMID: 31992528. doi:10.1016/j.arth.2020.01.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。