文献速递关节外科

严格筛选后孤立的聚乙烯衬垫更换治疗全膝置换术后屈曲不稳效果优良

Isolated Polyethylene Insert Exchange for Flexion Instability After Primary Total Knee Arthroplasty Demonstrated Excellent Results in Properly Selected Patients.
PubMed 文献 · J Arthroplasty · 2020-01-10

本研究回顾性分析30例患者31膝因初次全膝置换术后屈曲不稳而接受孤立聚乙烯衬垫更换的病例,平均随访41个月。严格掌握适应证下,仅6.5%的膝需要再次翻修,疼痛和功能评分显著改善。

要点

  • 严格筛选患者行孤立聚乙烯衬垫更换,再翻修率仅6.5%。
  • 术后疼痛评分从70分改善至86分,功能评分从39分改善至44分。
  • 术前影像学对线和假体位置优良是选择该术式的前提。

核心结论

  • 在严格选择的患者中,孤立聚乙烯衬垫更换治疗全膝置换术后屈曲不稳平均随访41个月成功率超过90%,疼痛和功能评分显著改善。

研究设计与样本

  • 回顾性研究,纳入2009至2016年间由同一资深术者连续施行的418例翻修全膝置换术中,因初次全膝置换术后屈曲不稳而接受孤立聚乙烯衬垫更换的31膝(30例患者),平均随访41个月(范围24至85个月)。

主要发现

  • 31膝中仅2膝(6.5%)因复发性不稳需后续假体翻修手术。
  • 膝关节协会疼痛评分从术前70分改善至术后86分(P < .0001)。
  • 膝关节协会功能评分从术前39分改善至术后44分(P = .015)。

关键数值与推荐

  • 术前影像学需显示对线和假体位置优良才考虑孤立聚乙烯衬垫更换。
  • 术中需确认假体旋转、尺寸和固定均优良,且屈伸间隙可平衡,方行孤立聚乙烯衬垫更换。

临床怎么用

  • 对初次全膝置换术后屈曲不稳患者,在术前影像学对线和假体位置优良、术中假体旋转尺寸固定均优良且屈伸间隙可平衡时,可考虑行孤立聚乙烯衬垫更换。

局限性

  • 需更长期随访以确定结果是否随时间持久。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Historically, isolated polyethylene exchange (IPE) for flexion instability after total knee arthroplasty (TKA) has demonstrated generally poor and unpredictable results. The purpose of this study is to evaluate the results of a single surgeon's strict indications and protocol for IPE for flexion instability after primary TKA. METHODS: Between 2009 and 2016, 418 revision TKAs were performed by the senior author. Patients were considered for IPE if they demonstrated excellent radiographic alignment and component positioning preoperatively. Intraoperatively, if component rotation, sizing, and fixation were all excellent and the flexion and extension gaps could be balanced, then IPE was performed. We retrospectively reviewed 31 knees in 30 patients who were treated with IPE specifically for flexion instability after primary TKA. The mean follow-up was 41 months (range, 24-85 months). Nineteen knees were cruciate-retaining TKAs revised to a more constrained "deep-dish" ultracongruent insert, and 12 posterior-stabilized TKAs were revised to thicker posterior-stabilized insert. RESULTS: At a mean follow-up of 41 months, only 2 of 31 knees (6.5%) required subsequent component revision surgery for recurrent instability. Knee Society pain scores improved from 70 preoperatively to 86 postoperatively (P < .0001), and function scores improved from 39 points preoperatively to 44 points postoperatively (P = .015). CONCLUSION: IPE for flexion instability in carefully selected patients was successful in over 90% of patients for a mean follow-up of 41 months. Pain and function scores significantly improved. Longer-term follow-up is necessary to determine whether these results are durable over time.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Green CC, Haidukewych GJ. Isolated Polyethylene Insert Exchange for Flexion Instability After Primary Total Knee Arthroplasty Demonstrated Excellent Results in Properly Selected Patients. J Arthroplasty. 2020. PMID: 31992529. doi:10.1016/j.arth.2020.01.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。