文献速递运动医学

肩袖修复中不同锚钉周围积液形成比较:全缝线、PEEK与生物复合锚钉

The formation of perianchor fluid associated with various suture anchors used in rotator cuff repair: all-suture, polyetheretherketone, and biocomposite anchors.
PubMed 文献 · Bone Joint J · 2019-01-01

该研究纳入73例接受经骨等效肩袖修复的患者,比较全缝线、PEEK及两种生物降解锚钉周围积液情况及肩袖愈合。结果显示全缝线与PEEK锚钉周围积液发生率均为41.7%,而两种生物降解锚钉分别为8.1%和10.8%,组间差异显著;积液存在与肩袖愈合完整性无关。

要点

  • 全缝线与PEEK锚钉周围积液发生率均较高(41.7%),生物降解锚钉较低(8.1%和10.8%)。
  • 组内两种锚钉间积液发生率和严重程度无显著差异,但组间比较有显著差异。
  • 锚钉周围积液的存在与肩袖愈合失败无显著关联。

核心结论

  • 尽管全缝线和PEEK锚钉不可吸收,全缝线锚钉在肩袖修复后产生的骨反应较少。
  • 选择锚钉时除初始固定强度外,还应考虑术后生物学反应。

研究设计与样本

  • 对73例接受经骨等效肩袖修复的患者进行分组研究,组1(37例)使用锚钉A(30%β-磷酸三钙+70%快速吸收聚乳酸-羟基乙酸共聚物)和锚钉B(全缝线),组2(36例)使用锚钉C(23%微β-磷酸三钙+77%聚乳酸对映体)和锚钉D(PEEK聚合物)。
  • 术后约一年通过MRI评估锚钉周围积液的存在与严重程度(0-4级)及肩袖愈合情况。

主要发现

  • 锚钉周围积液信号发生率:锚钉A为3例(8.1%),锚钉B为4例(10.8%),锚钉C为15例(41.7%),锚钉D为15例(41.7%)。
  • 积液严重程度分布(1:2:3:4级):锚钉A为2:1:0:0,锚钉B为2:2:0:0,锚钉C为12:2:0:1,锚钉D为11:3:0:1。
  • 锚钉A与B之间、锚钉C与D之间积液发生率和严重程度无显著差异,但组1与组2锚钉间有显著差异。
  • 肩袖愈合失败率:组1为7例(18.9%),组2为9例(25.0%),无显著差异;积液存在与锚钉类型及肩袖修复完整性无关。

关键数值与推荐

  • 积液严重程度分级:0级无锚钉周围积液信号;1级极少积液;2级局部积液;3级积液环绕锚钉全长但直径小于锚钉直径两倍;4级积液环绕锚钉全长且直径大于锚钉直径两倍。

临床怎么用

  • 临床选择肩袖修复锚钉时,除考虑初始固定强度外,还需关注不同锚钉引起的术后骨反应差异。
  • 全缝线锚钉虽不可吸收,但骨反应较小,可作为减少锚钉周围积液的选项之一。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to compare the osseous reactions elicited by all-suture, polyetheretherketone (PEEK), and two different biodegradable anchors used during rotator cuff repair. PATIENTS AND METHODS: Transosseous-equivalent rotator cuff repair was performed in 73 patients. The patients were divided into two groups, in both of which two different medial-row anchors were used. In group 1, anchor A comprised 30% β-tricalcium phosphate (TCP) + 70% fast-absorbing poly lactic-co-glycolic acid copolymer (85% polylactic acid enantiomers + 15% polyglycolic acid) and anchor B comprised all-sutures. In group 2, anchor C comprised 23% micro β-TCP + 77% polylactic acid enantiomers and anchor D comprised PEEK polymer. There were 37 patients in group 1 and 36 patients in group 2. The presence and severity of fluid collection around anchors and healing of the rotator cuff were assessed using MRI scans, approximately one year postoperatively. The severity of the collection was graded as 0 (no perianchor fluid signal), 1 (minimal perianchor fluid), 2 (local collection of fluid), 3 (fluid collection around the whole length of the anchor but of a diameter less than twice the anchor diameter), or 4 (fluid collection around the whole length of the anchor and of a diameter greater than twice the anchor diameter). RESULTS: A perianchor fluid signal was seen in three patients (8.1%) with anchor A, four (10.8%) with anchor B, 15 (41.7%) with anchor C, and 15 (41.7%) with anchor D. The severity of the collection around anchor was grade 2:1:0:0 for anchor A, grade 2:2:0:0 for anchor B, grade 12:2:0:1 for anchor C, and grade 11:3:0:1 for anchor D (grade 1:2:3:4, respectively). The prevalence and severity of fluid formation was not significantly different between anchors A and B, and anchors C and D. However, on intergroup analysis, there were significant differences for the prevalence and severity of fluid formation between anchors in group 1 and group 2. The prevalence of failure to heal was not significant in group 1 (seven, 18.9%) or group 2 (nine, 25.0%). There was no relationship between the presence of perianchor fluid and each type of anchor, and the integrity of the rotator cuff repair, in either group. CONCLUSION: Despite the nonabsorbable nature of all-suture and PEEK anchors, all-suture anchors produced less osseous reaction after rotator cuff repair. In deciding which kind of anchor to use, consideration should be given not only to the strength of the initial fixation, but also to the postoperative biological reaction. Cite this article: Bone Joint J 2019;101-B:1506-1511.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Kim SH, Yang SH, Rhee SM, et al. The formation of perianchor fluid associated with various suture anchors used in rotator cuff repair: all-suture, polyetheretherketone, and biocomposite anchors. Bone Joint J. 2019. PMID: 31786997. doi:10.1302/0301-620X.101B12.BJJ-2019-0462.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。