文献速递运动医学

外侧缘固定增强修复构造改善肩袖足印区接触特性

Improved Rotator Cuff Footprint Contact Characteristics With an Augmented Repair Construct Using Lateral Edge Fixation.
PubMed 文献 · Am J Sports Med · 2019-12-04

结果显示增强构造在所有外展和旋转角度下接触力与接触压力均显著更高,峰值接触压力在特定角度也显著更高。结论认为外侧缘固定可生物力学上优化腱骨接触,可能促进肌腱愈合。

要点

  • 增强TOE修复在所有外展和旋转角度下接触力平均高4.9 N、接触压力平均高23.1 kPa。
  • 在0°和30°外展下30°内旋及30°外旋时,增强构造峰值接触压力显著更高。
  • 外侧缘固定仅需少量额外手术操作即可改善生物力学接触特性。

核心结论

  • 与经典TOE技术相比,附加外侧缘固定的增强构造显示出更优的足印区接触特性。

研究设计与样本

  • 增强修复使用2根 luggage tag 缝线固定外侧缘并纳入外侧排锚钉。
  • 使用Tekscan压力传感器置于修复肌腱下方采集足印区接触面积、力、峰值压力和接触压力数据。

主要发现

  • 增强构造在所有外展角度和所有旋转角度下接触力显著更大(平均差异4.9 N)。
  • 增强构造在所有外展角度和所有旋转角度下接触压力显著更大(平均差异23.1 kPa)。
  • 在0°和30°肩外展下30°内旋及30°外旋时,增强构造峰值接触压力显著更大。

临床怎么用

  • 在经典TOE修复基础上增加外侧缘固定(2根luggage tag缝线纳入外侧排锚钉)可能以最小额外手术 effort 改善腱骨接触,或有助于优化肌腱愈合。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The transosseous-equivalent (TOE) rotator cuff repair construct has become the gold standard for the repair of medium and large rotator cuff tears. Repair failure, however, continues to be a problem. One contributing factor may be the inability of the TOE repair to replicate the native footprint contact characteristics during shoulder movement, especially in rotation. This results in higher strain across the repair, which leads to gapping and predisposes the construct to failure. In an effort to better reproduce the native compression forces throughout the footprint, an augmented TOE construct supplemented with lateral edge fixation is proposed, and the contact characteristics were compared with those of the gold standard TOE construct. HYPOTHESIS: The augmented TOE repair will demonstrate improved footprint contact characteristics when compared with the classic TOE repair. STUDY DESIGN: Controlled laboratory study. METHODS: Ten fresh-frozen cadaveric shoulders underwent supraspinatus repair using both the classic TOE double-row construct and the augmented TOE repair. For the augmented repair, 2 luggage tag sutures were used to secure the lateral edge and incorporated into the lateral row anchors. A Tekscan pressure sensor (Tekscan Inc) placed under the repaired tendon was used to collect footprint contact area, force, peak pressure, and contact pressure data for each construct. RESULTS: The augmented construct demonstrated significantly greater contact forces (average difference, 4.9 N) and significantly greater contact pressures (average difference, 23.1 kPa) at all degrees of abduction and all degrees of rotation. At 30° of internal and 30° of external rotation at both 0° and 30° of shoulder abduction, the augmented construct demonstrated significantly greater peak contact pressures. CONCLUSION: The augmented construct showed superior contact characteristics when compared with the classic TOE technique. The addition of lateral edge fixation to the classic TOE repair significantly improves bone-tendon contact characteristics with minimal additional surgical effort. CLINICAL RELEVANCE: The results of this study indicate that lateral augmentation of the classic TOE repair produces a biomechanically superior construct that may optimize tendon healing.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Urch E, Lin CC, Itami Y, et al. Improved Rotator Cuff Footprint Contact Characteristics With an Augmented Repair Construct Using Lateral Edge Fixation. Am J Sports Med. 2019. PMID: 31800297. doi:10.1177/0363546519888182

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。