文献速递关节外科

Corail 非骨水泥股骨柄尺寸对全髋关节置换翻修率的影响:41,265 例分析

The Effect of Size for a Hydroxyapatite-Coated Cementless Implant on Component Revision in Total Hip Arthroplasty: An Analysis of 41,265 Stems.
PubMed 文献 · J Arthroplasty · 2019-11-06

基于澳大利亚关节置换登记系统 1999 年至 2017 年因骨关节炎行初次全髋关节置换并使用 Corail 柄的 41,265 例数据,分析股骨柄尺寸与翻修率的关系。结果显示 8 号和 9 号小尺寸柄 13 年累积翻修率为 7.7%,显著高于 10-20 号柄的 3.0%,主要翻修原因为松动,前入路使用时差异最明显。

要点

  • 8/9 号 Corail 柄 13 年累积翻修率 7.7%,10-20 号为 3.0%(P < .001)。
  • 调整年龄性别后,8/9 号带领和无领柄翻修风险均显著高于 10-20 号。
  • 8/9 号柄主要翻修原因为松动(65.2%),前入路使用时翻修风险最高。

核心结论

  • 小尺寸 Corail 柄的翻修率约为大尺寸柄的 4 倍,松动是最常见翻修诊断。
  • 前入路使用时小尺寸柄的翻修风险最为明显。

研究设计与样本

  • 基于澳大利亚关节置换登记系统 1999 年 9 月至 2017 年 12 月的回顾性队列分析。
  • 纳入因骨关节炎行初次全髋关节置换、使用 Corail 柄、非骨水泥髋臼杯、现代摩擦界面及 28/32/36 mm 头尺寸的 41,265 例。
  • 主要结局为股骨组件翻修,数据按年龄、性别和头尺寸调整,并进一步分析手术入路的影响。

主要发现

  • 8/9 号柄翻修主要原因为松动(65.2%),10-20 号柄为 31.5%。

关键数值与推荐

  • 小尺寸 Corail 柄(8/9 号)13 年累积翻修率 7.7%,大尺寸(10-20 号)为 3.0%。
  • 8/9 号带领柄翻修 HR 6.22,无领柄 HR 3.28,均以 10-20 号对应类型为参照。
  • 8/9 号柄前入路翻修 HR 14.44。
  • 8/9 号柄松动翻修占比 65.2%,10-20 号柄为 31.5%。

临床怎么用

  • 选用小尺寸 Corail 柄时应警惕较高的松动翻修风险,尤其在前入路时。
  • 术前规划可参考登记系统数据,对 8/9 号柄患者加强随访和影像监测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The cementless Corail is one of the most commonly used stems in total hip arthroplasty (THA). The aim of this study was to investigate whether there was a difference in revision rate for smaller stems. METHODS: All primary THA procedures recorded by the Australian Joint Replacement Registry from September 1999 to December 2017 performed for osteoarthritis using the Corail stem, a cementless acetabular cup, modern bearing surfaces (ceramic/ceramic, ceramic/cross-linked polyethylene, and metal/cross-linked polyethylene), and 28 mm, 32 mm, and 36 mm head sizes were included. The primary outcome measure was femoral component revision. Data were analyzed and adjusted for age, gender, and head size. Further analysis investigated the effects of surgical approach. RESULTS: There was 41,265 primary THAs recorded. The cumulative percent revision (CPR) at 13 years was 7.7% (5.5, 10.7) for stem sizes 8 and 9 and 3.0% (2.4, 3.8) for sizes 10-20 (P < .001). When adjusted for age and gender, the sizes 8 and 9 collared (hazard ratio [HR]: 6.22 [3.84-10.06], P < .001) and collarless (HR: 3.28 [2.41-4.45], P < .001) had a higher CPR than the collared and collarless size 10-20. The size 8 and 9 stems performed with an anterior approach had the highest CPR (HR: 14.44 [6.21-33.56], P < .001). The main reason for revision of size 8 and 9 femoral stems was loosening (65.2%, compared to 31.5% for 10-20 femoral stems). CONCLUSIONS: Smaller Corail stems have 4 times the rate of revision compared with the larger femoral sizes with loosening being the most common diagnosis. This is most evident when using an anterior approach.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Hoskins WT, Bingham RJ, Lorimer M, et al. The Effect of Size for a Hydroxyapatite-Coated Cementless Implant on Component Revision in Total Hip Arthroplasty: An Analysis of 41,265 Stems. J Arthroplasty. 2019. PMID: 31787355. doi:10.1016/j.arth.2019.10.060

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。