大直径股骨头与现代内衬用于髋关节翻修的孤立头衬置换结局
本研究纳入138髋(132例)因聚乙烯磨损/骨溶解、急性感染、金属沉着病等行孤立头衬置换的翻修全髋关节置换病例,使用32/36/40 mm股骨头及交联聚乙烯内衬(75%为带唇或偏心内衬),平均随访3.5年。5年无翻修生存率94.6%,脱位率仅3%,最常见并发症为感染(4%)。结论认为大直径股骨头与现代内衬可提供优于既往报告的稳定性。
要点
- 大直径股骨头联合现代内衬行孤立头衬置换,5年无翻修生存率94.6%,脱位率仅3%。
- 最常见并发症为感染(4%),其次为脱位(3%)和trunnionosis(1%)。
- 未发现显著影响结局的人口学、手术或植入物因素。
核心结论
- 使用大直径股骨头和现代内衬行孤立头衬置换,稳定性优于既往≤28 mm股骨头的报告,最常见并发症为感染。
研究设计与样本
- 回顾性队列研究,纳入138髋(132例)行孤立头衬置换的翻修全髋关节置换病例,平均随访3.5年(1.0-9.1年)。
主要发现
- 5年任何原因无翻修生存率94.6%,无菌原因无翻修生存率98.2%。
- 11髋(8%)发生并发症,7髋(5%)需再次翻修手术。
- 翻修后4髋(3%)脱位,5髋(4%)感染,1髋(1%)因trunnionosis翻修。
- 未发现显著影响结局的人口学或手术因素。
关键数值与推荐
- 翻修指征:聚乙烯磨损/骨溶解57%,急性感染27%,金属沉着病13%,其他2%。
- 股骨头直径:32 mm占23%,36 mm占62%,40 mm占15%。
- 所有翻修均使用交联聚乙烯内衬,104髋(75%)使用带唇和/或偏心内衬。
- 统计学显著性设定为P < .05。
临床怎么用
- 对于需行孤立头衬置换的翻修全髋关节置换病例,可考虑使用32-40 mm大直径股骨头联合现代交联聚乙烯内衬以提高稳定性。
- 术后需警惕感染,其为本组最常见并发症。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Previous reports on the outcomes of isolated head and liner exchange in revision total hip arthroplasty have found high rates of instability after these surgeries. Most reports have studied constructs using ≤28 mm femoral heads. The purpose of this study was to determine if modern techniques with the use of larger head sizes can improve the rate of instability after head and liner exchange. METHODS: We identified 138 hips in 132 patients who underwent isolated head and liner exchange for polyethylene wear/osteolysis (57%), acute infection (27%), metallosis (13%), or other (2%). All patients underwent revision with either 32 (23%), 36 (62%), or 40 (15%) mm diameter heads. Cross-linked polyethylene was used in all revisions. Lipped and/or offset liners were used in 104 (75%) hips. Average follow-up was 3.5 (1.0-9.1) years. Statistical analyses were performed with significance set at P < .05. RESULTS: Revision-free survivorship for any cause was 94.6% and for aseptic causes was 98.2% at 5 years. 11 (8%) hips experienced a complication with 7 (5%) hips requiring additional revision surgery. After revision, 4 (3%) hips experienced dislocation, 5 (4%) hips experienced infection, and 1 (1%) hip was revised for trunnionosis. No demographic or surgical factors significantly affected outcomes. CONCLUSION: Our study shows that isolated head and liner exchange using large femoral heads and modern liners provides for better stability than previous reports. The most common complication was infection. We did not identify specific patient, surgical, or implant factors that reduced the risk of instability or other complication.
引用
- Sutter EG, Akram F, Miller A, et al. Outcomes of Isolated Head and Liner Exchange Using Large Femoral Heads and Modern Liners in Revision Total Hip Arthroplasty. J Arthroplasty. 2019. PMID: 31812483. doi:10.1016/j.arth.2019.11.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。