文献速递关节外科创伤骨科

钽锥在单期膝关节置换翻修治疗假体周围感染的中期结果:单中心研究

Midterm Results After Tantalum Cones in 1-Stage Knee Exchange for Periprosthetic Joint Infection: A Single-Center Study.
PubMed 文献 · J Arthroplasty · 2019-11-15

结果显示锥相关无翻修生存率为83%±3.8(95%CI 74-90),无感染生存率为89%±4.2(95%CI 76-93),HSS膝关节评分从术前47±16改善至末次随访60±17分。

要点

  • 单期翻修联合钽锥治疗感染性全膝关节置换术后严重骨缺损的中期生存率良好。
  • 锥相关无任何翻修生存率83%,无感染生存率89%。
  • 既往因感染行翻修手术史显著增加锥翻修风险(P < .001)。

核心结论

  • 单期膝关节置换翻修使用钽锥治疗假体周围感染合并严重骨缺损的中期锥相关生存率和无感染生存率良好,功能结果合理。

研究设计与样本

  • 采用旋转铰链或纯铰链系统联合股骨和/或胫骨钽锥,进行 septic 和 aseptic 生存分析,前瞻性评估功能结局,平均随访49.9±18.8个月(范围24-88个月)。

主要发现

  • 15例(21%)患者再次翻修,其中8例(11.1%)因感染,7例(10%)因无菌性松动,12例(17%)需更换钽锥。
  • 锥相关无任何翻修生存率为83%±3.8(95%CI 74-90),无感染生存率为89%±4.2(95%CI 76-93)。
  • 假体类型(P = .8)或植入锥类型(P = .6)与失败无显著相关性;既往因感染行翻修手术史增加锥翻修风险(P < .001)。
  • 术前HSS膝关节评分从47±16(范围14-87)改善至末次随访60±17(范围24-84)分。

关键数值与推荐

  • 锥相关无任何翻修生存率83%±3.8(95%CI 74-90)。
  • 无感染生存率89%±4.2(95%CI 76-93)。
  • HSS膝关节评分从术前47±16改善至末次随访60±17分。

临床怎么用

  • 对于假体周围感染合并严重骨缺损的全膝关节置换翻修,可考虑单期翻修联合多孔钽锥重建,中期生存率和功能结果可接受。
  • 既往因感染行翻修手术史的患者锥翻修风险显著增加,需加强术后监测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The use of tantalum cones to reconstruct extensive bone defects in revision total knee arthroplasty has been established. We aimed to evaluate the midterm results after 1-stage knee exchange for periprosthetic joint infection using tantalum cones. METHODS: Seventy-two patients (mean age, 70 ± 8.2 years) treated with a 1-stage exchange for infected total knee arthroplasty using porous tantalum cones, between 2011 and 2016, were retrospectively included. Either rotating or pure hinge system in combination with femoral and/or tibial cones was used. Survivorship analysis (septic and aseptic) was performed. Prospectively, functional outcome was assessed at a mean follow-up of 49.9 ± 18.8 months (range, 24-88). RESULTS: A total of 15 patients (21%) were rerevised, 8 (11.1%) for infection and 7 (10%) for aseptic loosening, requiring cone exchange in 12 patients (17%). Cone-related survival free from any revision was 83% ± 3.8 standard deviation (95% confidence interval, 74-90), and infection-free survival was 89% ± 4.2 standard deviation (95% confidence interval, 76-93). No significant correlation was reported between the types of prosthesis used (P = .8) or implanted cones and failure (P = .6). History of a previous septic revision increased the risk of cone revision after the index surgery (P < .001). Preoperative Hospital for Special Surgery knee score improved from 47 ± 16 (range, 14-87) to 60 ± 17 (range, 24-84) points at the latest follow-up. CONCLUSION: First study reports on outcomes of the 1-stage exchange using tantalum cones for knee periprosthetic joint infection with additional severe bone loss. Midterm cone-related and infection-free survival offered good results and provided reasonable functional outcomes.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Abdelaziz H, Biewald P, Anastasiadis Z, et al. Midterm Results After Tantalum Cones in 1-Stage Knee Exchange for Periprosthetic Joint Infection: A Single-Center Study. J Arthroplasty. 2019. PMID: 31813812. doi:10.1016/j.arth.2019.11.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。