文献速递关节外科

活动平台限制型假体在367例人工膝关节翻修术中的中期结果

Varus-Valgus Constrained Implants With a Mobile-Bearing Articulation: Results of 367 Revision Total Knee Arthroplasties.
PubMed 文献 · J Arthroplasty · 2019-11-20

5年再翻修累积发生率为9%,无菌性松动再翻修为3%;无活动平台相关脱位,膝关节评分从术前45分改善至末次随访77分。

要点

  • 活动平台限制型假体翻修术后5年再翻修累积发生率为9%。
  • 无菌性松动再翻修5年累积发生率为3%,无活动平台脱位。
  • 膝关节评分从术前45分显著改善至末次随访77分。

核心结论

  • 活动平台限制型假体翻修术后功能改善和5年再翻修累积发生率可接受,无活动平台结构相关独特并发症。
  • 需更长期随访确定假体远期生存率。

研究设计与样本

  • 翻修时平均年龄67岁,平均随访4年。

主要发现

  • 5年任何再翻修累积发生率为9%,无菌性松动再翻修累积发生率为3%。
  • 17例清创冲洗、10例麻醉下手法松解、9例假体周围骨折。
  • 无活动平台脱位(spin-out)发生。
  • 膝关节协会评分从术前45分改善至末次随访77分(P < .001)。

关键数值与推荐

  • 翻修主要指征:无菌性松动158例(43%)、二期翻修后再植入120例(33%)、不稳61例(17%)、其他28例(7%)。

临床怎么用

  • 对于韧带稳定性受损的翻修全膝关节置换术,活动平台限制型假体中期再翻修风险可接受且无活动平台脱位。
  • 术后需关注感染、无菌性松动及假体周围骨折等并发症。

局限性

  • 平均随访仅4年,需更长期随访确定远期假体生存率。
  • 单中心回顾性设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Varus-valgus constrained (VVC) implants are used for compromised ligamentous stability in revision total knee arthroplasties (TKAs). Mobile-bearing VVC implants may reduce rotational forces; yet, limited clinical data exist. The purpose of this study is to report mid-term risk of re-revision, complications, and clinical outcomes with a mobile-bearing VVC implant. METHODS: Three hundred thirty-seven patients (367 TKAs) who underwent revision TKA with a mobile-bearing VVC implant between 1999 and 2013 at a single institution were reviewed. Mean age at revision was 67 years. Mean follow-up was 4 years. The main indications for revision were aseptic loosening in 158 cases (43%), reimplantation after 2-stage exchange arthroplasty in 120 (33%), instability in 61 (17%), and other in 28 (7%). Clinical outcomes were assessed by Knee Society Scores, and survivorship was analyzed with death as the competing risk. RESULTS: The 5-year cumulative incidences of any re-revision or re-revision for aseptic loosening were 9% and 3%, respectively. Twenty-six knees (7%) were re-revised: 15 for infection, 6 for aseptic loosening, and 5 for other causes. There were 17 cases of irrigation and debridement, 10 cases of manipulations under anesthesia, and 9 cases of periprosthetic fractures. There were no bearing "spin-outs." The mean Knee Society Scores improved from 45 preoperatively to 77 at most recent follow-up (P < .001). CONCLUSION: The functional improvement and 5-year cumulative incidence of revision of a mobile-bearing VVC implant demonstrated acceptable outcomes with no unique complications related to the mobile-bearing construct. Additional follow-up will be needed to determine long-term implant survivorship.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Reina N, Salib CG, Pagnano MW, et al. Varus-Valgus Constrained Implants With a Mobile-Bearing Articulation: Results of 367 Revision Total Knee Arthroplasties. J Arthroplasty. 2019. PMID: 31826835. doi:10.1016/j.arth.2019.11.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。