遗忘关节评分(FJS)的效度、信度与实用性系统综述

Determining the Validity, Reliability, and Utility of the Forgotten Joint Score: A Systematic Review.
PubMed 文献 · J Arthroplasty · 2019-11-05

该研究系统检索了PubMed/MEDLINE、EMBASE和Cochrane系统综述数据库,纳入13篇评估遗忘关节评分(FJS)测量性能的文章,使用COSMIN清单评价方法学质量。结果显示FJS有强证据支持良好的结构效度和重测信度,中等证据支持良好的内部一致性,地板与天花板效应低(<15%),但反应度和测量误差结果不一致。作者推荐在预期获得高功能的全关节置换患者中长期使用FJS。

要点

  • FJS内部一致性高(Cronbach α >0.9),重测信度好或优(组内相关系数≥0.8)。
  • FJS地板与天花板效应总体较低(<15%),在功能良好与极佳患者间有较好区分潜力。
  • 反应度与测量误差证据不一致,长期评估全关节置换高功能患者推荐使用FJS。

核心结论

  • FJS有强证据支持良好的结构效度和重测信度,中等证据支持良好的内部一致性。
  • FJS地板与天花板效应很低,在功能良好与极佳患者间显示出很有前景的区分能力。
  • 尤其对全关节置换后预期获得高功能水平的患者,强烈推荐使用FJS进行长期治疗评估。

研究设计与样本

  • 系统综述,检索US National Library of Medicine(PubMed/MEDLINE)、EMBASE和Cochrane系统综述数据库。
  • 检索词涉及FJS、效度、信度、测量性能与患者报告结局测量(PROM)。
  • 使用COSMIN清单评价测量性能的方法学质量,共纳入13篇文章。

主要发现

  • 内部一致性持续较高(Cronbach α >0.9)。
  • 所有研究中重测信度为好或优(组内相关系数≥0.8)。
  • 结构效度方面所有文章均报告正面评价。
  • 地板与天花板效应总体较低(<15%)。
  • 反应度与测量误差方面发现结果不一致。

关键数值与推荐

  • 内部一致性:Cronbach α >0.9。
  • 重测信度:组内相关系数≥0.8。
  • 地板与天花板效应:<15%。

临床怎么用

  • 在预期全关节置换后获得高功能水平的患者中,推荐使用FJS进行长期治疗评估。

局限性

  • 反应度与测量误差的结果不一致。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: With improving patient outcome after total hip and total knee arthroplasty, patient-reported outcome measures (PROMs) have seen a parallel rise in average scores and ceiling effects. The Forgotten Joint Score (FJS) is a PROM that has been previously proposed to reduce this observed ceiling effect. However, the validity and reliability of the FJS has not been well analyzed. METHODS: The US National Library of Medicine (PubMed/MEDLINE), EMBASE, and the Cochrane Database of Systematic Reviews were queried using keywords pertinent to FJS, validity, reliability, measurement properties, and PROM. The methodological quality of measurement properties was evaluated using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. RESULTS: In total, 13 articles met the inclusion criteria and were included in this analysis. Internal consistency was consistently high (Cronbach alpha >0.9). Test-retest reliability was good or excellent (interclass correlation coefficient ≥0.8) in all studies. As for construct validity, all the articles reported a positive rating. Floor and ceiling effects overall were low (<15%). Conflicting results were found for responsiveness and measurement error. CONCLUSION: There is a strong evidence of good construct validity and test-retest reliability regarding the FJS, with moderate evidence of good internal consistency. Ceiling and floor effects were very low, showing a very promising discriminatory power between patients with a good outcome and patients with an excellent outcome. Therefore, especially in patients expected to achieve high levels of function after total joint replacement, we highly recommend the use of FJS for the long-term assessment of their treatment.