文献速递关节外科

用ESR和CRP筛查假体周围感染:理想截断值

Screening for Periprosthetic Joint Infections With ESR and CRP: The Ideal Cutoffs.
PubMed 文献 · J Arthroplasty · 2019-12-02

该回顾性研究分析81例假体周围感染(PJI)患者和83例非感染关节置换患者,评估ESR和CRP在标准MSIS截断值(30 mm/h和10 mg/L)下的敏感性与特异性。结果显示,标准截断值敏感性不足,而ESR 10 mm/h和CRP 5 mg/L可使敏感性分别≥95%,联合应用敏感性达100%但特异性降至54.7%。作者建议降低截断值以避免漏诊PJI。

要点

  • 标准MSIS截断值(ESR 30 mm/h、CRP 10 mg/L)筛查PJI敏感性低,假阴性多。
  • ESR 10 mm/h和CRP 5 mg/L可使敏感性分别≥95%。
  • 联合ESR 10 mm/h和CRP 5 mg/L敏感性100%,特异性54.7%。

核心结论

  • 使用ESR 30 mm/h和CRP 10 mg/L筛查PJI敏感性不可接受地低,假阴性多,建议降低阈值以避免漏诊PJI。

研究设计与样本

  • 回顾性分析81例PJI患者和83例非感染关节置换患者,计算ESR和CRP在30 mm/h和10 mg/L阈值下的敏感性和特异性,并确定使敏感性≥95%的最佳截断值。

主要发现

  • ESR截断值10 mm/h使敏感性≥95%(95%CI:85.2-97.6%)。
  • CRP截断值5 mg/L使敏感性≥95%(95%CI:87.1-98.4%)。
  • 联合ESR 10 mm/h和CRP 5 mg/L的敏感性为100%(95%CI:94.1-100%),特异性为54.7%(95%CI:46.4-62.3%)。

关键数值与推荐

  • 标准MSIS截断值:ESR 30 mm/h和CRP 10 mg/L,敏感性低、假阴性多。
  • 使敏感性≥95%的截断值:ESR 10 mm/h(95%CI:85.2-97.6%)和CRP 5 mg/L(95%CI:87.1-98.4%)。
  • 联合ESR 10 mm/h和CRP 5 mg/L:敏感性100%(95%CI:94.1-100%),特异性54.7%(95%CI:46.4-62.3%)。

临床怎么用

  • 筛查PJI时考虑降低ESR和CRP截断值至10 mm/h和5 mg/L以提高敏感性,减少漏诊。

局限性

  • 证据等级为III级,为回顾性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The purpose of this study was to (1) determine the sensitivity and specificity of erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) when screening for a periprosthetic joint infection (PJI) using the standard MSIS cutoff of 30 mm/h and 10 mg/L, respectively, and (2) determine the optimal ESR and CRP cutoff to achieve a sensitivity ≥95%. METHODS: We retrospectively analyzed 81 PJI patients and 83 noninfected arthroplasty patients. We calculated the sensitivity and specificity (and 95% confidence intervals) for ESR and CRP at thresholds of 30 mm/h and 10 mg/L, respectively. We determined the optimal cutoff for both ESR and CRP to yield a sensitivity greater than or equal to 95%. RESULTS: The ESR cutoff that resulted in a sensitivity ≥ to 95% (95% CI: 85.2-97.6%) was 10 mm/h, and the CRP cutoff that resulted in a sensitivity ≥ to 95% (95% CI: 87.1-98.4%) was 5 mg/L. The sensitivity and specificity with a combined ESR and CRP of 10 mm/h and 5 mg/L was 100% (95% CI: 94.1-100%) and 54.7% (95% CI: 46.4-62.3%). CONCLUSION: When using ESR and CRP as a screening tool with the accepted cutoffs of 30 mm/h and 10 mg/L, there is an unacceptably low sensitivity and a high number of false negatives. Therefore, further recommendation must be given to lowering these thresholds to avoid the devastating morbidity of a missed PJI. LEVEL OF EVIDENCE: III.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Bingham JS, Hassebrock JD, Christensen AL, et al. Screening for Periprosthetic Joint Infections With ESR and CRP: The Ideal Cutoffs. J Arthroplasty. 2019. PMID: 31883823. doi:10.1016/j.arth.2019.11.040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。