文献速递脊柱外科小儿骨科

脊柱侧凸手术中椎弓根螺钉置入:不同技术的准确性与效率现场模拟数据

Pedicle Screw Instrumentation in Scoliosis Surgery: On Site Simulation Data on Accuracy and Efficiency With Different Techniques.
PubMed 文献 · Spine (Phila Pa 1976) · 2020-01-01

本研究为前瞻性实验性现场模拟研究,5名脊柱 fellow 在20个脊柱侧凸模拟模型上各置入10枚椎弓根螺钉,比较传统椎弓根探针与创新序贯钻孔技术(联合或不联合CT导航)的准确性与效率。结果显示钻孔技术效率优于探针技术(P<0.01),导航技术准确性优于徒手技术(P=0.036),导航联合序贯钻孔可显著改善准确性与效率。

要点

  • 序贯钻孔技术(徒手或导航)置钉效率优于椎弓根探针技术(P<0.01)。
  • 导航技术置钉准确性优于徒手技术(P=0.036)。
  • 导航联合序贯钻孔可同时改善脊柱侧凸手术椎弓根螺钉置入的准确性与效率。

核心结论

  • 导航可提高椎弓根螺钉置入的准确性,序贯钻孔可安全地提高效率,二者联合可显著改善脊柱侧凸手术中椎弓根螺钉置入的准确性与效率。

研究设计与样本

  • 前瞻性实验性研究,采用现场模拟;5名脊柱 fellow 在20个脊柱侧凸模拟模型上各置入10枚椎弓根螺钉。
  • 比较四种技术:传统椎弓根探针与创新序贯钻孔技术,各自联合或不联合CT导航;采用卡方检验、Student t检验或方差分析及Bonferroni事后检验进行双变量分析。

主要发现

  • 钻孔技术(徒手和导航)效率优于椎弓根探针技术(P<0.01)。
  • 导航技术准确性优于徒手技术(P=0.036)。
  • 大多数椎弓根破坏为内侧(n=32/52),凹侧顶椎椎弓根(T4右侧)破坏发生率最高。
  • 徒手与导航椎弓根探针技术效率无显著差异(P=0.261),徒手与导航钻孔技术效率无显著差异(P=1.00)。

关键数值与推荐

  • 钻孔技术对比椎弓根探针技术效率:P<0.01。
  • 导航技术对比徒手技术准确性:P=0.036。
  • 徒手对比导航椎弓根探针技术效率:P=0.261。
  • 徒手对比导航钻孔技术效率:P=1.00。

临床怎么用

  • 现场手术模拟可作为教授高级操作技能的有前景的概念。
  • 在脊柱侧凸手术椎弓根螺钉置入中,可考虑将导航与序贯钻孔技术联合使用以同时改善准确性与效率。

局限性

  • 证据等级为4级。
  • 研究基于模拟模型而非真实患者,样本为5名脊柱 fellow 和20个模拟模型。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Prospective experimental study with on-site simulation. OBJECTIVE: To compare the accuracy and efficiency of different techniques for pedicle screw instrumentation (PSI). SUMMARY OF BACKGROUND DATA: Improving the safety and efficiency of PSI is a critical step to reduce the complication rates and the cost of scoliosis surgery. Innovative operative techniques for PSI have shown to safely improve efficiency, thereby reducing cost. Surgical simulation is a valuable tool to study different operative techniques. METHODS: Five spine fellows instrumented 20 simulation models of a scoliotic spine with 10 pedicle screws per model. Four techniques were studied, including the conventional pedicle probe and the innovative sequential drilling technique, with or without computed tomography (CT)-based navigation. Our primary outcome measures were efficiency and accuracy of PSI. We analyzed the data with bivariate analyses using the Chi-square test for categorical variables and the Student t test or ANalysis Of VAriance with Bonferroni post-hoc tests for continuous variables. RESULTS: The drilling techniques (free hand and navigated) were more efficient as compared with the pedicle probe techniques (P < 0.01). The navigated techniques resulted in better accuracy as compared with the free hand techniques (P = 0.036). Most pedicle breaches were medial (n = 32/52). The concave apical pedicle (T4 right side) had the highest incidence of breaches. There was no significant difference in efficiency comparing the free hand and the navigated pedicle probe techniques (P = 0.261) or comparing the free hand drilling and the navigated drilling techniques (P = 1.00). CONCLUSION: On site surgical simulation is a promising concept for teaching advanced procedural skills. Our findings suggest that navigation improves the accuracy of PSI while sequential drilling safely improves efficiency. Combining navigation with sequential drilling can significantly improve the accuracy and the efficiency of PSI in scoliosis surgery, as previously suggested with our published clinical data. LEVEL OF EVIDENCE: 4.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Peiro-Garcia A, Teles AR, Ojaghi R, et al. Pedicle Screw Instrumentation in Scoliosis Surgery: On Site Simulation Data on Accuracy and Efficiency With Different Techniques. Spine (Phila Pa 1976). 2020. PMID: 31809473. doi:10.1097/BRS.0000000000003358

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。