磁共振成像诊断前交叉韧带撕裂患者半月板斜坡损伤的诊断效能:系统综述与荟萃分析
该系统综述与荟萃分析纳入8篇文章共9项研究、883例前交叉韧带撕裂并重建患者,评估MRI以关节镜为参考标准诊断半月板斜坡损伤的效能。汇总敏感度为0.71(95%CI 0.59-0.81),特异度为0.94(95%CI 0.88-0.97),HSROC曲线下面积为0.90(95%CI 0.87-0.92)。结论为MRI敏感度中等、特异度优秀,无论MRI是否怀疑斜坡损伤均建议常规关节镜评估。
要点
- MRI诊断斜坡损伤汇总敏感度0.71、特异度0.94、HSROC曲线下面积0.90。
- 磁场强度、膝关节位置和MRI判读医师与敏感度异质性相关。
- 磁场强度与特异度异质性相关。
核心结论
- MRI诊断前交叉韧带撕裂患者半月板斜坡损伤的敏感度中等、特异度优秀。
- 无论MRI是否怀疑斜坡损伤,均建议常规关节镜评估斜坡损伤的存在。
- 需要进一步开展包含高分辨率MRI和合适膝关节位置的临床影像学研究以建立诊断算法。
研究设计与样本
- 系统综述与荟萃分析,遵循PRISMA DTA声明修订版指南检索PubMed、EMBASE和Cochrane Library。
- 纳入以MRI为索引试验、关节镜为参考标准诊断斜坡损伤的诊断效能研究。
- 共纳入8篇文章中的9项研究,883例前交叉韧带撕裂并重建患者。
- 采用双变量和分层汇总受试者工作特征(HSROC)模型评估诊断效能,并进行荟萃回归分析异质性来源。
主要发现
- 斜坡损伤的汇总敏感度为0.71(95%CI 0.59-0.81)。
- 汇总特异度为0.94(95%CI 0.88-0.97)。
- HSROC曲线下面积为0.90(95%CI 0.87-0.92)。
- 磁场强度(P < .01)、患者膝关节位置(P = .04)和MRI判读医师(P = .04)与敏感度异质性相关。
- 磁场强度(P = .03)与特异度异质性相关。
关键数值与推荐
- MRI诊断斜坡损伤汇总敏感度0.71(95%CI 0.59-0.81)、特异度0.94(95%CI 0.88-0.97)、HSROC曲线下面积0.90(95%CI 0.87-0.92)。
- 磁场强度与敏感度异质性相关(P < .01),患者膝关节位置与敏感度异质性相关(P = .04),MRI判读医师与敏感度异质性相关(P = .04)。
- 磁场强度与特异度异质性相关(P = .03)。
临床怎么用
- MRI对斜坡损伤敏感度中等,阴性结果不能排除斜坡损伤。
- 无论MRI是否怀疑斜坡损伤,均建议常规关节镜评估斜坡损伤。
- MRI判读时需考虑磁场强度、膝关节位置和判读医师对诊断效能的影响。
局限性
- 纳入研究数量有限(9项研究,来自8篇文章)。
- 敏感度存在显著异质性,与磁场强度、膝关节位置和MRI判读医师相关。
- 需进一步开展临床影像学研究以建立包含高分辨率MRI和合适膝关节位置的诊断算法。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The clinical importance of meniscal ramp lesions in patients with anterior cruciate ligament (ACL) tear has emerged as a major issue. However, the diagnostic accuracy of magnetic resonance imaging (MRI) for detecting ramp lesions has a wide range. PURPOSE: To perform a systematic review and meta-analysis of the diagnostic performance of MRI for diagnosing ramp lesion in patients with ACL tear. STUDY DESIGN: Systematic review and meta-analysis. METHODS: A literature search of PubMed, EMBASE, and the Cochrane Library was performed based on the revised guidelines for the PRISMA DTA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses of Diagnostic Accuracy Studies) statement. Diagnostic performance studies using MRI as the index test and arthroscopy as the reference standard for ramp lesion were included. Bivariate and hierarchical summary receiver operating characteristic modeling was used to evaluate the diagnostic performance. Meta-regression analyses were performed to identify potential sources of heterogeneity. RESULTS: The review and meta-analysis included 9 studies from 8 articles (883 patients with ACL tear and reconstruction). The summary sensitivity, summary specificity, and area under the hierarchical summary receiver operating characteristic for ramp lesion were 0.71 (95% CI, 0.59-0.81), 0.94 (95% CI, 0.88-0.97), and 0.90 (95% CI, 0.87-0.92), respectively. Among the potential covariates, magnet strength (P < .01), patient knee position (P = .04), and MRI interpreter (P = .04) were associated with heterogeneity in terms of sensitivity, whereas magnet strength (P = .03) was associated with heterogeneity in terms of specificity. CONCLUSION: MRI demonstrated moderate sensitivity and excellent specificity for diagnosing ramp lesion. Routine arthroscopic assessment is recommended for the presence of ramp lesion, regardless of whether it is suspected on MRI. Further clinicoradiological studies of diagnostic algorithms are needed for identifying ramp lesion, including high-resolution MRI with appropriate knee position.
引用
- Koo B, Lee SH, Yun SJ, et al. Diagnostic Performance of Magnetic Resonance Imaging for Detecting Meniscal Ramp Lesions in Patients With Anterior Cruciate Ligament Tears: A Systematic Review and Meta-analysis. Am J Sports Med. 2019. PMID: 31684739. doi:10.1177/0363546519880528
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。