利用MRI预测前交叉韧带重建腘绳肌自体移植物尺寸
该回顾性队列研究纳入68例急性前交叉韧带完全断裂患者,比较术前MRI腘绳肌横截面积与术中自体移植物直径的相关性,并计算获得至少8mm移植物所需的最小横截面积。结果显示1.5T与3T MRI组的截断值分别为18.8mm²和17.5mm²(原文数值照抄),相关性良好但非极好。
要点
- 术前MRI测量的腘绳肌横截面积与术中移植物直径相关性良好(r=0.53~0.70)。
- 1.5T MRI组获得8mm移植物所需平均半腱肌+股薄肌横截面积截断值为18.8mm²。
- 3.0T MRI组相应截断值为17.5mm²,可辅助术前移植物选择。
核心结论
- 常规膝关节损伤协议的MRI可用于术前预测前交叉韧带重建腘绳肌自体移植物尺寸。
- 该预测有助于骨科医生进行移植物选择和手术规划。
研究设计与样本
- 回顾性队列研究,纳入68例急性前交叉韧带完全断裂患者,由三名接受专科培训的医生于2010年4月至2013年7月在Carilion Clinic完成手术。
- 排除既往前交叉韧带重建、多韧带损伤和急性腘绳肌损伤史;1.5T组29例,3T组39例。
- 由单一肌肉骨骼放射科医生测量MRI上股骨内侧髁最宽处和关节线处的腘绳肌横截面积,术中记录移植物能通过的最小孔洞直径。
- 采用Pearson相关系数和简单逻辑回归分析,重测19条肌腱评估评分者内信度(ICC=0.96,95%CI 0.93-0.98)。
主要发现
- 1.5T组中与移植物尺寸相关性最强的三个测量:股骨内侧髁处半腱肌(r=0.69;p<0.001)、股骨内侧髁处半腱肌+股薄肌(r=0.70;p<0.001)、半腱肌+股薄肌平均值(r=0.64;p<0.001)。
- 3T组上述三个测量的相关性分别为0.53、0.56、0.56(均p<0.001)。
- 总体相关性良好但非极好。
关键数值与推荐
- 为获得至少8mm的腘绳肌自体移植物,1.5T MRI组平均半腱肌+股薄肌横截面积截断值为18.8mm²。
- 3.0T MRI组相应截断值为17.5mm²。
临床怎么用
- 术前可利用常规膝关节MRI测量腘绳肌横截面积,预测自体移植物直径是否可达8mm。
- 根据磁场强度(1.5T或3T)参考相应截断值,辅助移植物选择和手术规划。
局限性
- 回顾性研究设计,样本量68例,可能存在选择偏倚。
- MRI测量由单一放射科医生完成,虽信度良好但未评估评分者间信度。
- 未报告移植物直径<8mm与失败风险的具体关联数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Hamstring autografts with a diameter of less than 8 mm for ACL reconstruction have an increased risk of failure, but there is no consensus regarding the best method to predict autograft size in ACL reconstruction. QUESTIONS/PURPOSES: (1) What is the relationship between hamstring cross-section on preoperative MRI and intraoperative autograft size? (2) What is the minimum hamstring tendon cross-sectional area on MRI needed to produce an autograft of at least 8 mm at its thickest point? METHODS: This was a retrospective cohort study of 68 patients. We collectively reviewed patients who underwent ACL reconstruction by three separate fellowship-trained surgeons at the Carilion Clinic between April 2010 and July 2013. We searched the patient records database of each surgeon using the keyword "ACL". A total of 293 ACL reconstructions were performed during that time period. Of those, 23% (68 patients) had their preoperative MRI (1.5 T or 3 T magnet) performed at the Carilion Clinic with MRI confirmation of acute total ACL rupture. Exclusion criteria included previous ACL reconstructions, multiligamentous injuries, and history of acute hamstring injuries.After applying the exclusion criteria, there were 29 patients in the 1.5 T magnet group and 39 in the 3 T group. Median age (range) was 29 years (12 to 50) for the 1.5 T group and 19 years (9 to 43) for the 3 T group. The patients were 41% female in the 1.5 T group and 23% female in the 3 T group. Use of 1.5 T or 3 T magnets was based on clinical availability and scheduling. The graft's preoperative cross-sectional area was compared with the intraoperative graft's diameter. The MRI measurements were performed by a single musculoskeletal radiologist at the widest point of the medial femoral condyle and at the joint line. Intraoperative measurements were performed by recording the smallest hole the graft could fit through at its widest point. Pearson's correlation coefficients were calculated to determine the relationship between graft size and tendon cross-sectional area. A simple logistic regression analysis was used to calculate the cutoff cross-sectional areas needed for a graft measuring at least 8 mm at its thickest point. Intrarater reliability was evaluated based on re-measurement of 19 tendons, which produced an overall intraclass correlation coefficient (ICC) of 0.96 95% (CI 0.93 to 0.98). A p value < 0.05 was considered significant. RESULTS: In general, the correlation between MRI-measured hamstring thickness and hamstring graft thickness as measured in the operating room were good but not excellent. The three measurements that demonstrated the strongest correlation with graft size in the 1.5 T group were the semitendinosus at the medial femoral condyle (r = 0.69; p < 0.001), the semitendinosus and gracilis at the medial femoral condyle (r = 0.70; p < 0.001), and the mean semitendinosus and gracilis (r = 0.64; p < 0.001). These three measurements had correlation values of 0.53, 0.56, and 0.56, respectively, in the 3 T MRI group (all p values < 0.001). To create an 8-mm hamstring autograft, the mean semitendinosus plus gracilis cutoff values areas were 18.8 mm and 17.5 mm for the 1.5 T and 3.0 T MRI groups, respectively. CONCLUSIONS: Imaging performed according to routine knee injury protocol can be used to preoperatively predict the size of hamstring autografts for ACL reconstructions. In clinical practice, this can assist orthopaedic surgeons in graft selection and surgical planning. LEVEL OF EVIDENCE: Level II, diagnostic study.
引用
- Hollnagel K, Johnson BM, Whitmer KK, et al. Prediction of Autograft Hamstring Size for Anterior Cruciate Ligament Reconstruction Using MRI. Clin Orthop Relat Res. 2019. PMID: 31764334. doi:10.1097/CORR.0000000000000952
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。