文献速递运动医学关节外科

全缝线锚钉在中小型肩袖撕裂关节镜修复后的沉降现象

All-Suture Anchor Settling After Arthroscopic Repair of Small and Medium Rotator Cuff Tears.
PubMed 文献 · Am J Sports Med · 2019-11-13

本研究回顾性纳入88例中小型肩袖撕裂行关节镜单排全缝线锚钉修复的患者,按肩部骨密度分为三组,通过MRI测量锚钉深度与沉降。结果发现骨密度越高,术后即刻锚钉距皮质越深;随访时锚钉沉降随初始深度增加而增大,但最终锚钉深度及肩袖完整性在骨密度组间无显著差异。

要点

  • 肩部骨密度较高者术后即刻全缝线锚钉距皮质更远,骨密度较低者更靠近皮质下骨。
  • 随访MRI显示锚钉沉降随术后即刻锚钉深度增加而增大,但超过一定距离后不再进一步沉降。
  • 基于骨密度的分组间,最终锚钉深度及肩袖肌腱完整性无显著差异。

核心结论

  • 全缝线锚钉在关节镜单排肩袖修复中,术后锚钉位置与肩部骨密度相关,但随访时锚钉沉降轻微且无临床意义。

研究设计与样本

  • 回顾性队列研究,证据等级3级,纳入88例中小型肩袖撕裂行关节镜单排全缝线锚钉修复的患者,按术前肩部骨密度分为三组。

主要发现

  • 术后即刻MRI锚钉深度在三组间差异显著:A组(骨密度<0.4 g/cm2)3.62±2.02 mm,B组(0.4-0.6 g/cm2)5.18±2.13 mm,C组(>0.6 g/cm2)6.30±3.34 mm(P = .001)。
  • 术后即刻锚钉深度与骨密度呈正相关(r = 0.374;P = .001),但随访MRI时锚钉深度无组间差异。
  • 随访MRI显示锚钉沉降随术后即刻锚钉深度增加而增大(r = 0.769;P < .001),三组沉降量分别为A组1.33±1.08 mm、B组2.78±1.99 mm、C组3.81±2.19 mm(P = .001)。
  • 各组肩袖肌腱厚度充足比例无统计学差异:A组70.8%、B组72.7%、C组57.9%(P = .550)。

关键数值与推荐

  • 骨密度分组阈值:A组<0.4 g/cm2,B组0.4-0.6 g/cm2,C组>0.6 g/cm2。
  • 肩袖完整性采用Sugaya分类:厚度充足组为II级或以下,厚度不足组为III级或以上。

临床怎么用

  • 对于肩部骨密度较高的患者,全缝线锚钉术后即刻位置可能更深,随访中可发生轻微沉降,但未显示临床意义。
  • 骨密度较低患者锚钉更靠近皮质下骨,但随访锚钉深度及肩袖完整性无显著差异,提示全缝线锚钉沉降不影响结构结局。

局限性

  • 回顾性研究设计,证据等级3级。
  • 仅65例患者完成随访MRI。
  • 样本量有限,需更大规模研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: All-suture anchors are increasingly being used in rotator cuff repair. However, there are debates on the micromotion of all-suture anchors. PURPOSE: To perform rotator cuff repair on patients with rotator cuff tears and different shoulder bone mineral densities (BMDs) and investigate (1) where the anchor is located under the cortex, (2) if there is any anchor migration settling during follow-up, and (3) if structural outcome differs according to shoulder BMD. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: We retrospectively investigated 88 patients who underwent arthroscopic single-row repair for small- to medium-sized rotator cuff tears (age [mean ± SD], 58.8 ± 7.1 years) from 712 cases of rotator cuff tendon repair between November 2015 and February 2018. Inclusion criteria were as follows: use of an all-suture anchor; preoperative shoulder BMD; and magnetic resonance imaging (MRI) conducted preoperatively, 2 days after surgery, and 10 months after surgery. Patients were excluded from the study if they underwent open rotator cuff repair (n = 118), got surgery with a double-row technique (n = 178), underwent surgery with anchors other than the all-suture type (n = 273), received anchor insertion in sites other than the greater tuberosity owing to concomitant procedures such as biceps tenodesis and subscapularis repair (n = 29), did not take preoperative shoulder BMD (n = 15), had more than a large-size tear (n = 6), and were lost to follow-up (n = 5). After compression of the all-suture anchor during surgery, the strands were pulled multiple times to ensure that the anchor was fixed onto the bone with appropriate tension. BMD was measured before surgery. Depth to anchor (DA), anchor settling, and repaired rotator cuff integrity were measured with MRI. Patients were categorized into 3 groups: group A (BMD, <0.4 g/cm2; n = 31), group B (BMD, 0.4-0.6 g/cm2; n = 32), and group C (BMD, >0.6 g/cm2; n = 25). A total of 65 patients had follow-up MRI. On the basis of rotator cuff tendon integrity, patients were categorized into either a sufficient thickness group (group S, Sugaya classification grade II or lower; n = 44) or an insufficient thickness group (group I, Sugaya classification grade III or higher; n = 21). RESULTS: On time-zero MRI, the DA differed significantly among groups (group A, 3.62 ± 2.02 mm; group B, 5.18 ± 2.13 mm; group C, 6.30 ± 3.34 mm) (P = .001). The DA was deeper in patients with a higher BMD at time zero (r = 0.374; P = .001), but the DA did not differ at follow-up MRI (mean, 10.3 months after surgery). On follow-up MRI, anchor settling tended to increase with deeper time-zero DA (r = 0.769; P < .001). Anchor settling was significantly different among groups (group A, 1.33 ± 1.08 mm; group B, 2.78 ± 1.99 mm; group C, 3.81 ± 2.19 mm) (P = .001). The proportion of patients with sufficient thickness in each group did not show a statistical difference (group A, 70.8%; group B, 72.7%; group C, 57.9%) (P = .550). CONCLUSION: In conclusion, this study confirmed that the postoperative site of anchor insertion in arthroscopic single-row rotator cuff repair with all-suture anchors was located farther from the cortex in patients with higher shoulder BMD and closer to the subcortical bone in patients with lower BMD. On follow-up MRI, no further settling occurred past a certain distance from the cortex, and there was no significant difference in anchor depth or integrity of the rotator cuff tendon based on shoulder BMD. Therefore, minimal settling in the all-suture anchor did not show clinical significance.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Ro K, Rhee SM, Kim JY, et al. All-Suture Anchor Settling After Arthroscopic Repair of Small and Medium Rotator Cuff Tears. Am J Sports Med. 2019. PMID: 31718248. doi:10.1177/0363546519886547

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。