基质诱导自体软骨细胞植入后两种完全负重方案随机对照试验的至少10年临床与影像学结果
本研究为随机对照试验,70例患者接受基质诱导自体软骨细胞植入后分别采用8周或12周完全负重方案,随访10年时60例(85.7%)可评估。两组的临床和MRI评分在10年内均显著改善,除Tegner活动评分改善和组织结构恶化外,5至10年间无其他显著变化,两组间无差异。8周负重方案安全且未影响长期结果,10年满意度高。
要点
- 8周与12周完全负重方案在10年临床和影像学结果上无显著差异。
- MACI术后10年患者满意度高,93.3%对疼痛缓解满意,83.3%对运动能力满意。
- 8周负重康复方案安全,未危及长期结果。
核心结论
- MACI提供高满意度和超过10年的组织耐久性。
- 8周完全负重康复方案安全,未危及长期结果。
研究设计与样本
- 随机对照试验,证据等级1。
- 70例患者随机分配至8周(n=34)或12周(n=36)完全负重方案,均为股骨内侧或外侧髁MACI。
- 10年时60例(85.7%;8周组n=29,12周组n=31)可评估。
主要发现
- 全队列临床和MRI评分在10年内显著改善(P < .05)。
- 除Tegner活动评分改善(P = .041)和组织结构恶化(P = .030)外,5至10年间无其他显著变化(P > .05)。
- 10年时两组间无差异。
- 10年时8周组和12周组分别有81.5%和82.8%患者显示良好至优秀组织填充。
- 10年MRI显示7例移植失败,包括4例在10年MRI上(8周组n=1;12周组n=3)和3例未纳入当前分析而接受全膝关节置换术(8周组n=1;12周组n=2)。
临床怎么用
- MACI术后可采用8周完全负重康复方案,不危及长期临床和影像学结果。
- 长期随访应关注组织结构变化和移植失败风险。
局限性
- 3例接受全膝关节置换术的患者未纳入当前分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Longer term outcomes after matrix-induced autologous chondrocyte implantation (MACI) are lacking, while early postoperative weightbearing (WB) management has traditionally been conservative. PURPOSE: To investigate the longer term clinical and radiological outcomes after an 8-week (vs 12-week) WB protocol after MACI. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: A randomized study design allocated 70 patients to an 8- (n = 34) or 12-week (n = 36) approach to full WB after MACI of the medial or lateral femoral condyle. Patients were evaluated preoperatively; at 3, 12, and 24 months after surgery; and at 5 and 10 years after surgery. At 10 years (range, 10.5-11.5 years), 60 patients (85.7%; 8 weeks: n = 29; 12 weeks: n = 31) were available for review. Clinical outcomes included patient-reported outcomes, maximal isokinetic knee extensor and flexor strength, and functional hop capacity. High-resolution magnetic resonance imaging (MRI) was undertaken to assess the quality and quantity of repair tissue per the MOCART (magnetic resonance observation of cartilage repair tissue) system. A combined MRI composite score was also evaluated. RESULTS: Clinical and MRI-based scores for the full cohort significantly improved (P < .05) over the 10-year period. Apart from the Tegner activity score, which improved (P = .041), as well as tissue structure (P = .030), which deteriorated, there were no further statistically significant changes (P > .05) from 5 to 10 years. There were no 10-year differences between the 2 WB rehabilitation groups. At 10 years, 81.5% and 82.8% of patients in the 8- and 12-week groups, respectively, demonstrated good-excellent tissue infill. Graft failure was observed on MRI at 10 years in 7 patients overall, which included 4 located on 10-year MRI (8 weeks: n = 1; 12 weeks: n = 3) and a further 3 patients (8 weeks: n = 1; 12 weeks: n = 2) not included in the current analysis who proceeded to total knee arthroplasty. At 10 years, 93.3% of patients were satisfied with MACI for relieving their pain, with 83.3% satisfied with their ability to participate in sport. CONCLUSION: MACI provided high satisfaction levels and tissue durability beyond 10 years. The outcomes of this randomized trial demonstrate a safe 8-week WB rehabilitation protocol without jeopardizing longer term outcomes.
引用
- Ebert JR, Fallon M, Ackland TR, et al. Minimum 10-Year Clinical and Radiological Outcomes of a Randomized Controlled Trial Evaluating 2 Different Approaches to Full Weightbearing After Matrix-Induced Autologous Chondrocyte Implantation. Am J Sports Med. 2019. PMID: 31765228. doi:10.1177/0363546519886548
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。