文献速递关节外科创伤骨科

肘部桡骨小头关节置换术中期结果:两种不同假体的多中心前瞻性研究

Midterm results of radiocapitellar arthroplasty of the elbow: a multicentre prospective study on two different implants.
PubMed 文献 · Bone Joint J · 2019-01-01

该多中心前瞻性研究分析了31例接受两种桡骨小头关节假体(LRE和UNI-E)患者的的中期随访结果。平均随访6.8年,MEPS、m-ASES和Q-DASH评分均显著改善,两种假体间无差异。LRE用于无桡骨头畸形的原发性或创伤后骨关节炎患者、UNI-E用于需桡骨头切除的患者时,假体生存率高。

要点

  • 桡骨小头关节置换术在平均6.8年随访中显著改善肘关节功能。
  • LRE与UNI-E两种假体在功能评分改善上无差异。
  • LRE用于无桡骨头畸形的原发或创伤后骨关节炎患者时假体生存率高。

核心结论

  • 桡骨小头关节置换术在平均6.8年随访时显著改善肘关节功能。
  • 当LRE用于原发性或创伤后骨关节炎且无桡骨头畸形的患者,以及UNI-E用于需桡骨头切除的患者时,假体生存率高。

研究设计与样本

  • 多中心前瞻性病例系列研究,共纳入31例患者,平均年龄54岁(范围27至73岁)。
  • 其中9例为原发性骨关节炎,17例为创伤后骨关节炎,3例为肱骨小头骨坏死,2例为骨折。
  • 共实施17例Lateral Resurfacing Elbow(LRE)假体和14例Uni-Elbow Radio-Capitellum Implant(UNI-E)假体置换。
  • 术前和术后评估采用Mayo肘关节性能评分(MEPS)、Quick Disabilities of the Arm, Shoulder and Hand(Q-DASH)评分和改良American Shoulder Elbow Surgeons(m-ASES)评分。

主要发现

  • 平均随访6.8年(范围3.8至11.5年)。
  • MEPS平均改善50分(p < 0.001),m-ASES平均改善55分(p < 0.001),Q-DASH平均改善54分(p < 0.001)。
  • 两种假体之间未检测到评分差异。
  • 使用UNI-E假体的患者术前旋前和旋后功能更差。
  • 2例使用UNI-E假体的患者有无症状性明显松动的影像学证据。

临床怎么用

  • 对于无桡骨头畸形的原发性或创伤后骨关节炎患者,可考虑使用LRE假体行桡骨小头关节置换。
  • 对于需行桡骨头切除的患者,可考虑使用UNI-E假体行桡骨小头关节置换。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to analyze the results of two radiocapitellar prostheses in a large case series followed prospectively, with medium-term follow-up. PATIENTS AND METHODS: A total of 31 patients with a mean age of 54 years (27 to 73) were analyzed; nine had primary osteoarthritis (OA) and 17 had post-traumatic OA, three had capitellar osteonecrosis, and two had a fracture. Overall, 17 Lateral Resurfacing Elbow (LRE) and 14 Uni-Elbow Radio-Capitellum Implant (UNI-E) arthroplasties were performed. Pre- and postoperative assessment involved the Mayo Elbow Performance Score (MEPS), the Quick Disabilities of the Arm, Shoulder and Hand (Q-DASH) score, and the modified American Shoulder Elbow Surgeons (m-ASES) score. RESULTS: The mean follow-up was 6.8 years (3.8 to 11.5). The mean MEPS, m-ASES, and Q-DASH scores improved significantly by 50 (p < 0.001), 55 (p < 0.001), and 54 points (p < 0.001), respectively, with no differences being detected between the implants. Preoperative pronation and supination were worse in patients in whom the UNI-E was used. Two patients with the UNI-E implant had asymptomatic evidence of gross loosening. CONCLUSION: Radiocapitellar arthroplasty yielded a significant improvement in elbow function at a mean follow-up of 6.8 years, with a high implant survival rate when the LRE was used in patients with primary or post-traumatic OA, without radial head deformity, and when the UNI-E was used in patients in whom radial head excision was indicated. Cite this article: Bone Joint J 2019;101-B:1362-1369.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Giannicola G, Calella P, Bigazzi P, et al. Midterm results of radiocapitellar arthroplasty of the elbow: a multicentre prospective study on two different implants. Bone Joint J. 2019. PMID: 31674247. doi:10.1302/0301-620X.101B11.BJJ-2019-0155.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。