同一批年轻患者全髋关节置换中两种替代摩擦界面的18年随访研究
这项随机前瞻性试验纳入133例(266髋)小于55岁患者,每例一侧髋接受陶瓷对陶瓷全髋关节置换(C-O-C THA),另一侧接受陶瓷对高交联聚乙烯全髋关节置换(C-O-HXLPE THA)。平均随访17.1年,两组Harris髋关节评分、疼痛评分、患者满意度无差异,均无骨溶解,髋臼假体生存率分别为97%和98%,股骨假体均为99%。
要点
- C-O-C与C-O-HXLPE THA在平均17.1年随访中功能、疼痛和满意度无显著差异。
- 两组影像学及CT均未记录到骨溶解,髋臼假体生存率分别为97%和98%。
- C-O-C组有8髋(3%)出现可听见的摩擦音。
核心结论
- C-O-C THA和C-O-HXLPE THA在平均17.1年随访中均功能良好,且无骨溶解。
研究设计与样本
- 随机前瞻性试验于1999年1月至2003年4月纳入133例(266髋)小于55岁患者,每例一侧髋接受C-O-C THA、另一侧接受C-O-HXLPE THA。
主要发现
- 末次随访时两组Harris髋关节评分分别为94分与93分(P = .861),疼痛评分分别为43分与42分(P = .651),患者满意度评分分别为7.8分与7.6分(P = .379)。
- C-O-C THA组有8髋(3%)出现可听见的摩擦音。
- HXLPE年均穿透率为0.0162 ± 0.032 mm/年。
- 两组X线及CT扫描均未记录到骨溶解。
- 17.1年时髋臼假体生存率在C-O-C组为97%、在C-O-HXLPE组为98%(P = .923),股骨假体生存率两组均为99%。
临床怎么用
- 在年轻全髋关节置换患者中,C-O-C与C-O-HXLPE两种摩擦界面均可作为可选方案,长期功能与假体生存表现相近。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This study compares the long-term functional, radiographic, and computed tomography scan outcomes and implant survivorship of ceramic-on-ceramic total hip arthroplasty (C-O-C THA) and ceramic-on-highly cross-linked polyethylene total hip arthroplasty (C-O-HXLPE THA) in the same patients. METHODS: In this randomized, prospective trial conducted between January 1999 and April 2003, 133 patients (266 hips) younger than 55 years were enrolled. Each patient received C-O-C THA in 1 hip and a C-O-HXLPE THA in the other. The mean follow-up was 17.1 years (range, 15-18 years); there were 84 men and 49 women with a mean age of 53 ± 7 years (range, 25-55 years). RESULTS: At the latest follow-up, mean Harris hip scores (94 vs 93 points; P = .861), pain scores (43 vs 42 points; P = .651), and patient satisfaction scores (7.8 vs 7.6 points; P = .379) were not different between the 2 groups. Eight hips (3%) in the C-O-C THA had an audible squeaking sound. The mean annual penetration rate of HXLPE was 0.0162 ± 0.032 mm per year. No osteolysis was recorded on radiographs or computed tomography scans in either group. At 17.1 years, the survival rate of the acetabular component was 97% in the C-O-C bearing group and 98% in the C-O-HXLPE bearing group (P = .923). The survival rate of the femoral component was 99% in both groups. CONCLUSION: Both C-O-C THA and C-O-HXLPE THA functioned well, with no osteolysis at mean of 17.1-year follow-up.
引用
- Kim YH, Park JW. Eighteen-Year Follow-Up Study of 2 Alternative Bearing Surfaces Used in Total Hip Arthroplasty in the Same Young Patients. J Arthroplasty. 2019. PMID: 31672505. doi:10.1016/j.arth.2019.09.051
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。