直接前入路股骨头颈开窗联合打压植骨治疗早期非创伤性股骨头坏死
回顾性队列研究比较直接前入路灯泡术(股骨头颈开窗联合打压植骨)与传统髓芯减压治疗早期非创伤性股骨头坏死,灯泡组66髋、对照组59髋。两组术后1年内临床结果无显著差异,但灯泡组术后2年起Harris髋关节评分和UCLA活动评分显著更优;4年随访中灯泡组影像学进展(22.7% vs 44.1%)和接受全髋关节置换(15.2% vs 30.5%)均显著更少。
要点
- 直接前入路灯泡术治疗早期非创伤性股骨头坏死,术后2年起临床评分显著优于传统髓芯减压。
- 4年随访灯泡组影像学进展22.7%、全髋置换15.2%,均显著低于对照组。
- 两组术后1年内临床结果无显著差异,早期功能恢复质量相当。
核心结论
- 直接前入路灯泡术治疗早期非创伤性股骨头坏死,较传统髓芯减压获得显著更好的结果。
研究设计与样本
- 回顾性队列研究,灯泡组66髋接受直接前入路股骨头颈开窗联合打压植骨,对照组59髋接受传统髓芯减压。
- 随访至术后4年,评估Harris髋关节评分、UCLA活动评分及影像学进展和全髋关节置换。
主要发现
- 两组功能恢复质量无显著差异,术后1年内临床结果无显著差异。
- 灯泡组术后2年至末次随访Harris髋关节评分和UCLA活动评分显著更优。
- 4年随访灯泡组影像学进展22.7% vs 44.1%,接受全髋关节置换15.2% vs 30.5%,均显著更少。
关键数值与推荐
- 4年随访影像学进展:灯泡组22.7%,对照组44.1%。
- 4年随访接受全髋关节置换:灯泡组15.2%,对照组30.5%。
临床怎么用
- 对早期非创伤性股骨头坏死,可考虑直接前入路灯泡术以延缓影像学进展并降低全髋置换风险。
- 术后1年内两组临床结果相当,长期获益需随访至2年以上评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This study aimed to evaluate the effect of femoral head and neck fenestration combined with compacted autograft (light bulb procedure) through a direct anterior approach for early stage nontraumatic osteonecrosis of the femoral head. METHODS: We conducted a retrospective cohort study investigating 66 hips undergoing the light bulb procedure through the direct anterior approach (light bulb group) and 59 hips undergoing traditional core decompression (control group). Visual analog scale pain scores and range of hip motion were evaluated before discharge to assess the quality of functional recovery. Follow-up was conducted at 6 weeks, 3 months, 6 months, and annually after surgery until 4 years. The clinical effectiveness was evaluated by Harris hip score and the University of California Los Angeles activity-level score. Patients were followed up with postoperative X-ray and computed tomography. Survival was compared between the 2 groups by radiographic progression and receiving total hip arthroplasty. RESULTS: There was no significant difference in quality of functional recovery between the 2 groups. There were no significant differences in clinical outcomes within 1 year after surgery. Patients in the light bulb group had significantly better Harris hip scores and University of California Los Angeles activity-level scores from 2 years after surgery to the end of follow-up. During the 4-year follow-up, significantly fewer patients in light bulb group had radiographic progression (22.7% vs 44.1%) or received total hip arthroplasty (15.2% vs 30.5%). CONCLUSIONS: The light bulb procedure through a direct anterior approach offers significantly better results for the treatment of early stage nontraumatic osteonecrosis of the femoral head compared with traditional core decompression.
引用
- Wang Q, Li D, Yang Z, et al. Femoral Head and Neck Fenestration Through a Direct Anterior Approach Combined With Compacted Autograft for the Treatment of Early Stage Nontraumatic Osteonecrosis of the Femoral Head: A Retrospective Study. J Arthroplasty. 2019. PMID: 31761674. doi:10.1016/j.arth.2019.10.043
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。