高交联聚乙烯在全髋关节置换术治疗50岁以下股骨头坏死患者中的应用:至少10年随访

Highly Cross-Linked Polyethylene in Total Hip Arthroplasty in Patients Younger Than 50 Years With Osteonecrosis of the Femoral Head: A Minimum of 10 Years of Follow-Up.
PubMed 文献 · J Arthroplasty · 2019-10-15

本研究回顾性评估了85例(67例患者)50岁以下股骨头坏死患者使用高交联聚乙烯内衬的非骨水泥全髋关节置换术的长期结果,平均随访13.5年。结果显示Harris髋关节评分从术前49.3分改善至术后93.6分,无机械松动、翻修或骨溶解,平均线性磨损率为0.037 mm/y,支持在该高风险患者中继续使用金属对高交联聚乙烯摩擦界面。

要点

  • 50岁以下股骨头坏死患者金属对高交联聚乙烯全髋关节置换术后平均13.5年无翻修、无骨溶解。
  • Harris髋关节评分从术前49.3分显著改善至术后93.6分。
  • 平均线性磨损率为0.037 mm/y,年龄、性别、体重等因素未显示影响内衬穿透。

核心结论

  • 尽管高交联聚乙烯颗粒的长期影响未知,本研究中植入物生存率和磨损率令人满意,支持在50岁以下股骨头坏死患者中继续使用金属对高交联聚乙烯摩擦界面。

研究设计与样本

  • 回顾性评估连续85例(67例患者)50岁以下股骨头坏死患者,均接受同一位术者使用同类型植入物的非骨水泥全髋关节置换术,高交联聚乙烯内衬为Durasul,最低随访10年(平均13.5年,范围10-17.3年)。

主要发现

  • 平均Harris髋关节评分从术前49.3分(范围26-68分)改善至术后93.6分(范围87-98分)。
  • 股骨和髋臼组件均未显示机械松动,末次随访时无组件翻修。
  • X线和CT扫描未显示骨溶解。
  • 平均内衬磨损率为0.037 mm/y(范围0-0.099 mm/y)。
  • 单因素回归分析未显示年龄、性别、体重、活动水平、骨坏死病因、内衬厚度或髋臼杯外倾角对内衬穿透有影响。

临床怎么用

  • 对于50岁以下股骨头坏死患者,金属对高交联聚乙烯摩擦界面在全髋关节置换术中表现出良好的长期生存率和低磨损率,可作为避免硬对硬界面相关问题的选择。

局限性

  • 高交联聚乙烯颗粒的长期效应仍未知。
  • 证据等级为治疗性IV级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Polyethylene wear and subsequent periprosthetic osteolysis remain a major concern of total hip arthroplasty (THA) failure in young, active patients with osteonecrosis of the femoral head (ONFH). The literature is lacking regarding the long-term performance of highly cross-linked polyethylene (HXLPE) in these patients. The purpose of this study is to evaluate long-term results for cementless THA using metal-on-HXLPE bearing couplings in patients younger than 50 years with ONFH. METHODS: We retrospectively evaluated the clinical and radiographic results of a consecutive series of 85 THAs (in 67 patients) performed with HXLPE liners (Durasul) in patients younger than 50 years who had ONFH. All procedures were performed at a single institution by a single surgeon using the same type of implants. The minimum duration of follow-up was 10 years (mean, 13.5 years; range, 10-17.3 years). Wear was measured using computer software. Osteolysis was evaluated with the use of radiography and computed tomography. RESULTS: The mean Harris hip score was 49.3 points (range, 26-68 points) before surgery, which improved to 93.6 points (range, 87-98 points) after surgery. Neither femoral nor acetabular components displayed mechanical loosening, and no components had been revised by the final follow-up evaluation. Radiographs and computed tomography scans did not demonstrate osteolysis. The mean liner wear was 0.037 mm/y (range, 0-0.099 mm/y). With the data available, univariate regression analysis did not demonstrate that age, sex, weight, activity level, underlying cause of osteonecrosis, liner thickness, or cup inclination had any influence on liner penetration. CONCLUSION: Although the long-term effects of HXLPE particles remain unknown, the implant survivorship rate and wear rate in our study are promising and support the continued use of metal-on-HXLPE bearing couplings in these high-risk patients because they do not produce any of the issues associated with hard-on-hard couplings. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.