计算机自适应测试在全髋关节置换术后疗效评估中的准确性与有效性
本研究将计算机自适应测试(CAT)版HOOS和HOOS-JR与完整版问卷进行对比,分别分析354份HOOS和1547份HOOS-JR患者应答。CAT版可作为可靠、实用的替代方案,减轻患者负担并提高报告依从性。
要点
- CAT HOOS平均减少30%的题目(28题 vs 40题),测量精度与完整版相当。
- CAT版与标准问卷呈强线性关系(r>0.99),差异不随总分变化。
核心结论
- CAT HOOS和HOOS-JR与完整版问卷高度相关,且所需题目更少,可作为可靠、实用的替代方案。
研究设计与样本
- 将已开发的CAT HOOS和HOOS-JR应用于全髋关节置换术后患者的问卷应答,分别分析354份HOOS和1547份HOOS-JR应答。
主要发现
- CAT HOOS平均减少30%的题目(28题 vs 40题)。
- CAT版与标准问卷呈强线性关系(r>0.99)。
- Bland-Altman图显示CAT HOOS与完整HOOS的差异与总分无关。
临床怎么用
- CAT HOOS和HOOS-JR可用于全髋关节置换术后患者的疗效评估,减少题目负担并可能提高报告依从性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Probability-based computer algorithms that reduce patient burden are currently in high demand. These computer adaptive testing (CAT) methods improve workflow and reduce patient frustration, while achieving high measurement precision. In this study, we evaluated the accuracy and validity of the CAT Hip Disability and Osteoarthritis Outcome Score (HOOS) and the Hip Disability and Osteoarthritis Outcome Score Joint Replacement (HOOS-JR) by comparing them to the full version of these scoring systems in a subset of patients who had undergone total hip arthroplasties. METHODS: A previously developed CAT HOOS and HOOS-JR was applied to 354 and 1547 HOOS and HOOS-JR patient responses, respectively. Mean, standard deviations, Pearson's correlation coefficients, interclass correlation coefficients, frequency distribution plots, and Bland-Altman plots were used to compare the precision, validity, and accuracy between CAT scores and full-form scores. RESULTS: By modifying the questions to past responses, the CAT HOOS demonstrated a mean reduction of 30% of questions (28 vs 40 questions). There were no significant differences between the full HOOS and CAT HOOS with respect to pain (P = .73), symptoms (P = .94), quality of life (P = .99), activities of daily living (P = .82), and sports (P = .99). There were strong linear relationships between the CAT versions and the standard questionnaires (r > 0.99). The Bland-Altman plot showed that differences between CAT HOOS and full HOOS were independent of the overall scores. CONCLUSION: The CAT HOOS and HOOS-JR have high correlation and require fewer questions to finish compared to the standard full-form questionnaires. This may represent a reliable and practical alternative that may be less burdensome to patients and may help improve compliance for reporting outcome metrics.
引用
- Banerjee S, Plummer O, Abboud JA, et al. Accuracy and Validity of Computer Adaptive Testing for Outcome Assessment in Patients Undergoing Total Hip Arthroplasty. J Arthroplasty. 2019. PMID: 31761673. doi:10.1016/j.arth.2019.10.039
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。