文献速递关节外科

矢状面稳定性与假体设计影响全膝关节置换术后患者报告结局

Sagittal Stability and Implant Design Affect Patient Reported Outcomes After Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2019-10-16

这项匹配队列横断面研究纳入60例全膝关节置换术后1年患者,比较内侧稳定(MS)与非MS假体的矢状面稳定性及患者报告结局。结果显示MS假体组KT-1000翻译度显著降低、稳定性更优,PROMs和满意度更高;无论假体类型,矢状面更稳定的患者PROMs均更优。

要点

  • MS假体较非MS假体在全膝关节置换术后1年矢状面稳定性更优。
  • MS假体组患者报告结局和满意度均显著高于非MS假体组。
  • 矢状面稳定性更优的患者PROMs更好,与假体设计无关。

核心结论

  • MS全膝关节置换假体较非MS假体具有更大的矢状面稳定性和更好的PROMs及满意度。
  • 独立于假体设计,矢状面稳定性更优的患者报告结局更好。

研究设计与样本

  • 匹配队列横断面研究,纳入60例全膝关节置换术后1年随访患者。
  • 三位外科医生各完成10例MS假体全膝关节置换和10例非MS假体全膝关节置换。
  • 由盲法观察者使用KT-1000关节动度计、Lachman试验和前抽屉试验评估矢状面稳定性。

主要发现

  • MS假体组KT-1000翻译度显著降低,稳定性优于非MS假体组(P < .05)。
  • MS假体组PROMs较非MS假体组显著提高(P < .05)。
  • 按客观稳定性分组后,无论假体类型,稳定膝关节患者PROMs更优(P < .05),尤其在运动相关问题方面。

关键数值与推荐

  • MS假体组KT-1000翻译度显著低于非MS假体组(P < .05)。
  • MS假体组PROMs显著高于非MS假体组(P < .05)。
  • 稳定膝关节患者PROMs显著优于不稳定者(P < .05)。

临床怎么用

  • 全膝关节置换术中选择MS假体可能有助于改善术后矢状面稳定性和患者报告结局。
  • 术后评估矢状面稳定性(如KT-1000、Lachman试验、前抽屉试验)有助于识别PROMs可能更差的患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Joint stability is one of the goals of any joint replacement. The contribution of prosthesis design to sagittal stability in total knee arthroplasty (TKA) has emerged as an area of interest. The purpose of this study was to evaluate the sagittal stability of four prosthesis types and determine the effect on patient reported outcome measures (PROMs). METHODS: A matched-cohort cross-sectional study was performed on 60 patients after TKA at 1-year follow-up. Three surgeons performed 10 medially stabilized (MS) TKA and 10 non-MS TKA. Sagittal stability was assessed by a blinded observer using a KT-1000 arthrometer, Lachman's test, and the anterior drawer test. PROMs (Oxford, Knee Injury and Osteoarthritis Outcome Score, Western Ontario and McMaster Universities Osteoarthritis Index, Forgotten joint score) and visual analog scale assessed function and satisfaction. RESULTS: MS TKA had significantly decreased translation on KT-1000 and improved stability compared with non-MS TKA (P < .05). Increased PROMs were demonstrated in the MS TKA group compared with the non-MS TKA group (P < .05). When divided based on objective stability, regardless of the prosthesis type, patients with a stable knee had superior PROMs (P < .05), particularly in sport-related questions. CONCLUSION: The MS TKA had significantly greater sagittal stability, improved PROMs, and satisfaction compared with non-MS TKA. Independent of prosthesis design, patients with greater sagittal stability demonstrated improved PROMs.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Jones CW, Jacobs H, Shumborski S, et al. Sagittal Stability and Implant Design Affect Patient Reported Outcomes After Total Knee Arthroplasty. J Arthroplasty. 2019. PMID: 31735490. doi:10.1016/j.arth.2019.10.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。