标准与高屈曲后交叉韧带保留型全膝关节置换假体的长期比较
本研究比较标准CR与高屈曲CR全膝关节假体在长期随访中的活动度、临床与影像学结果、并发症率及生存率。共纳入290膝,平均随访10.1年,结果显示两组活动度、HSS评分、KSS疼痛与功能评分、WOMAC评分及影像学参数均无显著差异,高屈曲假体未显示优势。
要点
- 两组HSS、KSS疼痛与功能、WOMAC评分及影像学参数均无显著差异。
- 高屈曲CR假体未显示优于标准CR假体的临床或影像学优势。
核心结论
- 标准CR与高屈曲CR全膝关节假体均可获得良好的临床和影像学结果,高屈曲CR假体未显示任何优势。
主要发现
- Kaplan-Meier生存分析估计生存率标准CR组97.2%、CR-flex组95.6%(平均随访10.1年)。
临床怎么用
- 在选择CR全膝关节假体时,高屈曲设计未显示额外获益,标准CR假体仍是合理选择。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: High-flexion prostheses have been developed to achieve deep flexion after total knee arthroplasty. The purpose of this study is to compare standard NexGen (CR, cruciate-retaining) and high-flexion NexGen (CR-flex) total knee prostheses in terms of range of motion, clinical and radiologic outcomes, rates of complications, and survivorship in long-term follow-up. METHODS: From January 2000 to December 2008, 423 consecutive knees underwent total knee arthroplasty using standard CR or CR-flex prostheses. Fifty-three patients were lost to follow-up or declined to participate and 54 died, leaving 290 knees. The minimum duration of follow-up was 8 years (mean 10.1 years). Physical examination and knee scoring of patients were assessed preoperatively, at 6 months and 1 year after surgery, and annually thereafter. Supine anteroposterior and lateral radiographs and standing anteroposterior hip-to-ankle radiographs were obtained preoperatively and at each follow-up. RESULTS: Mean postoperative range of motions in the standard CR group and the CR-flex group were similar, showing no significant difference between the 2 groups (P = .853). At the time of the final follow-up, mean total Hospital for Special Surgery scores were similar between the 2 groups (P = .118). Mean Knee Society pain (P = .325) and function scores (P = .659) were also comparable between the 2 groups. Western Ontario and McMaster Universities Osteoarthritis Index score showed no intergroup difference either (P = .586). The mean hip-knee-ankle angle at the final follow-up was approximately the same (P = .940). Mean coronal angles of femoral and tibial component at final follow-up were also similar (P = .211 and P = .764, respectively). The prevalence of the radiolucent line was 0.6% in the standard CR group and 0.9% in the CR-flex group. Estimated survival rate according to Kaplan-Meier survival analysis was 97.2% in the standard CR group and 95.6% in the CR-flex group at mean follow-up of 10.1 years. CONCLUSION: This study suggests that excellent clinical and radiographic outcomes could be achieved with both standard and high-flexion CR total knee designs. High-flexion CR prosthesis did not show any advantages over the standard design.
引用
- Lee WG, Song EK, Choi SW, et al. Comparison of Posterior Cruciate-Retaining and High-Flexion Cruciate-Retaining Total Knee Arthroplasty Design. J Arthroplasty. 2019. PMID: 31676176. doi:10.1016/j.arth.2019.10.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。