螺钉-主动脉困境:CT扫描中改变患者体位对记录主动脉活动性至关重要
俯卧位CT显示13/14枚螺钉处主动脉移开。仰卧位平均距离13.6±4.8 mm,俯卧位8.9±5.4 mm(P=0.001),无螺钉侵犯管腔或使主动脉变形。
要点
- 仰卧位CT可能高估螺钉-主动脉关系,俯卧位CT可显示主动脉移开。
- 疑似压迫主动脉的14枚螺钉中,13枚在俯卧位CT上主动脉移开。
- 俯卧位CT可限制不必要的血管干预,有助于安全移除螺钉。
核心结论
- 仅仰卧位CT不能完全准确判定螺钉-主动脉关系,俯卧位CT可提供额外信息以更好 delineate。
主要发现
- 俯卧位CT显示14枚疑似压迫螺钉中13枚的主动脉移开,1枚关系不变。
- 螺钉水平主动脉距离仰卧位平均13.6±4.8 mm,俯卧位平均8.9±5.4 mm(P=0.001)。
- 未观察到螺钉侵犯主动脉管腔或使主动脉变形。
关键数值与推荐
- 疑似压迫主动脉的14枚螺钉中,俯卧位CT显示13枚主动脉移开。
- 螺钉水平主动脉距离仰卧位13.6±4.8 mm,俯卧位8.9±5.4 mm,P=0.001。
临床怎么用
- 对仰卧位CT显示螺钉-主动脉关系可疑者,可加做俯卧位CT以更好判定主动脉活动性。
- 俯卧位CT显示主动脉移开时,可安全移除螺钉而无需血管干预。
- 存在疑问时,可加做动脉造影以改善可视化。
局限性
- 本研究为回顾性图表审查,证据等级为3级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Retrospective chart review. OBJECTIVE: To determine if obtaining a prone computed tomography (CT)-scan can better delineate a questionable screw-aorta relationship. SUMMARY OF BACKGROUND DATA: Pedicle screw misplacement rate is reported between 6% and 15%. Studies looking at misplacements on a per patient basis show up to 14% of patients have screws at risk (impinging vital structures). A screw abutting the aorta is a management challenge and often requires vascular surgery intervention. However, CT scans routinely done in supine position may overestimate screw-aorta relationship. Change in patient position may allow the aorta to roll away and, in most cases, reveal an uncompromised aorta. This will allow safe removal of pedicle screws without any vascular intervention. METHODS: One hundred eleven spinal deformity patients who underwent Posterior spinal fusion from 2004 to 2009 were evaluated. Patients with concerning screw-aorta relationship underwent additional prone CT scan. Mobility of the aorta was determined and distance was compared using prone and supine CT scans. RESULTS: Two thousand two hundred ninety five screws were reviewed, 36 screws in 18 patients were in proximity to the aorta. Fourteen screws (nine patients) appeared to be impinging the aorta. On prone CT, 13 out of the 14 instances the aorta moved away from the screw. The average distance at the screw level was 13.6 ± 4.8 mm in supine position and 8.9 ± 5.4 mm in prone position (P = 0.001). In one instance the relationship was unchanged on prone CT. No screw was noted to violate the lumen or distort the aorta. CONCLUSION: Supine CT scan alone is not entirely accurate in determining screw-aorta relationship. Prone-CT scan provides additional information for better delineation. This additional diagnostic step can change the treatment option by limiting the need for vascular intervention. When in doubt, the additional use of an arteriogram can allow for improved visualization. LEVEL OF EVIDENCE: 3.
引用
- Sarwahi V, Galina J, Wendolowski S, et al. The Screw-Aorta Dilemma: Changing Patient Position in Computed Tomography Scan Is Critical in Documenting Aortic Mobility. Spine (Phila Pa 1976). 2020. PMID: 31770323. doi:10.1097/BRS.0000000000003344
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。