文献速递脊柱外科小儿骨科

韩国版体象障碍问卷-脊柱侧凸的信效度验证

Validation of the Korean Version of the Body Image Disturbance Questionnaire-Scoliosis.
PubMed 文献 · Spine (Phila Pa 1976) · 2020-01-01

本研究对英文版体象障碍问卷-脊柱侧凸版(BIDQ-S)进行韩语跨文化适配,并在152例青少年特发性脊柱侧凸(AIS)患者中检验其信效度。结果显示韩语版(K-BIDQ-S)各条目κ值均>0.6,重测ICC为0.912,Cronbach α为0.880,与K-SAQ、K-SRS-22外观域及主弯Cobb角均显著相关,判别效度良好。结论认为K-BIDQ-S信效度满意,适用于韩语AIS患者脊柱外观评估。

要点

  • K-BIDQ-S重测信度ICC为0.912,内部一致性α为0.880。
  • K-BIDQ-S与主弯角度相关r=0.688,可区分观察、支具或手术患者。

核心结论

  • K-BIDQ-S信效度满意,适用于韩语AIS患者脊柱畸形外观评估。

研究设计与样本

  • 对英文版BIDQ-S进行翻译/回译及跨文化适配,并将K-BIDQ-S与K-SRS-22外观域、K-SAQ邮寄给152例AIS患者。
  • 采用κ统计量评估条目一致性,计算组内相关系数(ICC)和Cronbach α评估信度,并通过与K-SAQ、K-SRS-22外观域比较评估聚合效度。

主要发现

  • K-BIDQ-S所有条目κ值均>0.6。
  • K-BIDQ-S重测信度ICC为0.912,内部一致性Cronbach α为0.880。
  • K-BIDQ-S与主弯角度相关显著,r=0.688。
  • K-BIDQ-S评分在需要观察、支具或手术的患者间差异显著,判别效度得到确认。

关键数值与推荐

  • K-BIDQ-S条目一致性κ值均>0.6。
  • 重测信度ICC=0.912,内部一致性α=0.880。
  • 与主弯角度相关r=0.688。

临床怎么用

  • 韩语AIS患者可用K-BIDQ-S评估脊柱外观相关的心理困扰。
  • K-BIDQ-S评分可辅助区分观察、支具或手术等不同治疗阶段患者的外观困扰程度。

局限性

  • 证据等级为3级。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Cross-cultural adaptation and validation of the Body Image Disturbance Questionnaire-Scoliosis OBJECTIVE.: The purpose of this study was to evaluate the reliability and validity of an adapted Korean version of the Body Image Disturbance Questionnaire-Scoliosis version (BIDQ-S). SUMMARY OF BACKGROUND DATA: A modified version of the BIDQ instrument has been validated in adolescent idiopathic scoliosis (AIS) to assess the perception of spinal appearance and psychological disturbance. However, there is no culturally adapted, reliable, and validated BIDQ-S for the Korean population. METHODS: Translation/retranslation of the English version of the BIDQ-S was conducted, and all steps of the cross-cultural adaptation process were performed. The Korean version of the BIDQ-S (K-BIDQ-S) and the previously validated appearance domain of the Korean version of the Scoliosis Research Society-22 Outcomes questionnaire (K-SRS-22) and Spinal Appearance Questionnaire (K-SAQ) were mailed to 152 patients with AIS. Reliability assessments were conducted using κ statistics to assess item agreements, and intraclass correlation coefficients (ICCs) and Cronbach α values were calculated. Convergent validity was evaluated by comparing the scores of the K-BIDQ-S, K-SAQ, and K-SRS-22 appearance domain and discriminant validity by analyzing relationships between K-BIDQ-S score and patient characteristics. RESULTS: All items of the K-BIDQ-S had κ values of agreement >0.6. The K-BIDQ-S showed excellent test/retest reliability with an ICC of 0.912. Internal consistency of the K-BIDQ-S was found to be very good (α = 0.880). Convergent validity testing demonstrated good correlations between the K-BIDQ-S and K-SAQ (r = 0.617), and between the K-BIDQ-S and K-SRS-22 (r = -651). The correlation between the K-BIDQ-S and major curve magnitude was significant (r = 0.688). Discriminant validity was confirmed by significant differences in K-BIDQ-S scores among patients requiring observation, bracing, or surgery. CONCLUSION: The K-BIDQ-S showed satisfactory reliability and validity, and thus, is considered suitable for the evaluation of spinal deformity appearance in Korean-speaking patients with AIS. LEVEL OF EVIDENCE: 3.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Bae SH, Son SM, Shin WC, et al. Validation of the Korean Version of the Body Image Disturbance Questionnaire-Scoliosis. Spine (Phila Pa 1976). 2020. PMID: 31770342. doi:10.1097/BRS.0000000000003328

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。