pQCT有限元分析较DXA在识别非椎体骨折患者中诊断性能更优
结果显示4%胫骨部位pQCT-FE属性组间差异显著,骨折比值比随该部位pQCT-FE属性每降低一个标准差而增加,AUROC在女性和男性中均高于DXA全髋骨密度,且DXA与pQCT-FE变量间AUROC差异有统计学意义。
要点
- 4%胫骨部位pQCT-FE属性在骨折患者与对照间差异显著。
- 女性kshear每降低1个标准差骨折OR=10.34(95%CI 1.91,43.98)。
- 男性kbend每降低1个标准差骨折OR=8.32(95%CI 4.15,33.84)。
核心结论
- pQCT-FE建模较DXA可提供增强的诊断性能,鉴于其成本适中,可能有助于临床应用。
研究设计与样本
- 比较pQCT-FE属性与DXA及标准pQCT区分外周低创伤骨折患者与健康对照的能力。
主要发现
- 组间pQCT-FE属性存在显著差异,尤其在4%胫骨部位。
- 女性4%胫骨部位kshear每降低1个标准差,骨折OR=10.34(95%CI 1.91,43.98)。
- 男性4%胫骨部位kbend每降低1个标准差,骨折OR=8.32(95%CI 4.15,33.84)。
- 女性kshear的AUROC为0.83,DXA全髋aBMD为0.72,pQCT胫骨小梁密度Trb vBMD为0.76。
- 男性kbend的AUROC为0.81,DXA全髋aBMD为0.62,Trb vBMD为0.71。
关键数值与推荐
- 女性4%胫骨kshear每降低1个标准差骨折OR=10.34(95%CI 1.91,43.98)。
- 男性4%胫骨kbend每降低1个标准差骨折OR=8.32(95%CI 4.15,33.84)。
- 女性kshear AUROC 0.83 vs DXA全髋aBMD 0.72 vs Trb vBMD 0.76。
- 男性kbend AUROC 0.81 vs DXA全髋aBMD 0.62 vs Trb vBMD 0.71。
- DXA与pQCT-FE变量AUROC差异:女性p=0.02,男性p=0.03。
临床怎么用
- pQCT-FE建模较DXA可提供增强的诊断性能,鉴于其成本适中,可能有助于临床应用。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: Due to limitations of the predominant clinical method for diagnosing osteoporosis, an engineering model based on a dedicated CT scanner for bone density and structure was applied in fracture patients and controls. Improved diagnostic performance was observed, which supports its potential use in future research and clinical practice. INTRODUCTION: Dual-energy X-ray absorptiometry (DXA), the predominant clinical method for diagnosing osteoporosis, has limitations in identifying individuals with increased fracture risk. Peripheral quantitative computed tomography (pQCT) provides additional information and can be used to generate finite element (FE) models from which bone strength properties can be estimated. We investigated the ability of pQCT-FE properties to distinguish peripheral low-trauma fracture patients from healthy controls, by comparison with DXA and standard pQCT. METHODS: One hundred and eight fracture patients (77 females aged 67.7 ± 7.9 years, 31 males aged 69.7 ± 8.9 years) were recruited from a hospital fracture liaison service. One hundred and twenty healthy community controls (85 females aged 69.8 ± 8.5 years, 35 males aged 68.9 ± 7.2 years) were recruited. RESULTS: Significant differences between groups were observed in pQCT-FE properties, especially at the 4% tibia site. Fracture odds increased most per standard deviation decrease in pQCT-FE at this location [shear stiffness estimate, kshear, in females, OR = 10.34, 95% CI (1.91, 43.98); bending stiffness estimate, kbend, in males, OR = 8.32, 95% CI (4.15, 33.84)]. Area under the receiver operating characteristics curve (AUROC) was observed to be highest with pQCT-FE properties at 4% the tibia site. In females, this was 0.83 for the pQCT-FE variable kshear, compared with 0.72 for DXA total hip bone density (TH aBMD) and 0.76 for pQCT tibia trabecular density (Trb vBMD); in males, this was 0.81 for the pQCT-FE variable kbend at the 4% tibia site, compared with 0.62 for TH aBMD and 0.71 for Trb vBMD. There were significant differences in AUROC between DXA and pQCT-FE variables in both females (p = 0.02) and males (p = 0.03), while no difference was observed in AUROC between primary pQCT and pQCT-FE variables. CONCLUSIONS: pQCT-FE modeling can provide enhanced diagnostic performance compared with DXA and, given its moderate cost, may be useful in clinical settings.
引用
- Jiang H, Robinson DL, Yates CJ, et al. Peripheral quantitative computed tomography (pQCT)-based finite element analysis provides enhanced diagnostic performance in identifying non-vertebral fracture patients compared with dual-energy X-ray absorptiometry. Osteoporos Int. 2019. PMID: 31720708. doi:10.1007/s00198-019-05213-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。