两种非骨水泥旋转平台胫骨托设计的前瞻性随机研究:术后疼痛、生物学固定与临床结局比较
这项前瞻性随机对照单盲研究纳入197例(205膝)初次全膝关节置换患者,比较LCS Complete POROCOAT(仅多孔涂层)与LCS Complete DUOFIX(多孔涂层加HA和4个peg)两种胫骨托设计,随访至10年。两组疼痛和患者报告结局无临床显著差异,但HA加peg组在所有时间点放射性透亮线更少,两组均无松动或骨溶解,仅多孔涂层组有1例因感染翻修。
要点
- HA加peg胫骨托在所有时间点放射性透亮线均少于仅多孔涂层托。
- 两组疼痛和患者报告结局无临床显著差异。
- 两组均无松动或骨溶解,仅多孔涂层组1例感染翻修。
核心结论
- HA加额外固定peg的胫骨托未在减少早期术后疼痛或改善患者报告结局方面带来获益,但显著减少放射性透亮线。
- 两种假体均表现出优异的生存率。
- 对于非骨水泥多孔涂层胫骨部件,非进展性放射性透亮线应视为正常。
研究设计与样本
- 前瞻性、随机对照、单盲研究,比较LCS Complete POROCOAT(仅多孔涂层)与LCS Complete DUOFIX(多孔涂层加HA和peg)胫骨托。
主要发现
- 两组疼痛或患者报告结局指标无临床显著差异。
- HA加peg的胫骨托在所有时间点放射性透亮线更少。
- 放射性透亮线与疼痛无相关性。
- 两组均无松动或骨溶解。
- 仅多孔涂层组有1例因感染翻修。
关键数值与推荐
- 两组疼痛和患者报告结局无临床显著差异。
- HA加peg组在所有时间点放射性透亮线少于仅多孔涂层组。
- 两组均无松动或骨溶解,仅多孔涂层组1例感染翻修。
- 两种假体均表现出优异生存率。
临床怎么用
- 使用非骨水泥多孔涂层胫骨部件时,非进展性放射性透亮线可视为正常。
- HA加peg设计未显示减少早期术后疼痛或改善患者报告结局的获益。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: With the demand for arthroplasty increasing worldwide year on year, there is a drive to improve prosthesis longevity. Biological fixation from cementless implants has been one method of trying to achieve this. We hypothesized that the addition of a hydroxyapatite (HA) coating and 4 pegs to a porous-coated tibial tray would provide a reduction in time to implant osseointegration, allowing for normal physiological stress transfer, thus improving early postoperative pain and rehabilitation as well as the elimination of radiolucent lines (RLLs). METHODS: A prospective, randomized controlled single-blinded study was undertaken, comparing postoperative pain, radiographic evidence of biological fixation, and clinical outcomes between patients undergoing primary total knee arthroplasty with either LCS Complete POROCOAT (porous coating only) or LCS Complete DUOFIX (porous coating plus HA and pegs) knee systems (DePuy Synthes, Warsaw, IN). In total, 197 patients (205 knees) were recruited into the study between November 2006 and November 2008 and have been followed for up to 10 years. RESULTS: There were no clinically significant differences in pain or patient-reported outcome measures when comparing the 2 designs but the tibial tray with pegs and HA showed fewer RLLs at all time points. There was no correlation between RLLs and pain and no instances of loosening or osteolysis in either group. There was 1 revision for infection in the porous coating only group. CONCLUSION: The tray design with HA and additional fixation pegs did not confer any benefit in terms of reduced early postoperative pain or improved patient-reported outcomes, although it did result in significantly fewer RLLs. Both implants demonstrated excellent survivorship. With a cementless porous-coated tibial component, nonprogressive RLLs should be considered normal.