文献速递运动医学关节外科

FEAR指数能否预测髋关节镜手术患者的微不稳定?

Can the FEAR Index Be Used to Predict Microinstability in Patients Undergoing Hip Arthroscopic Surgery?
PubMed 文献 · Am J Sports Med · 2019-10-11

本研究为诊断性队列研究(证据等级2),纳入200例连续髋关节镜手术患者,术中评估微不稳定,回顾性测量FEAR指数等影像学参数。最终分析150例患者167髋,不稳定组71髋(42.5%),稳定组96髋(57.5%)。在非发育不良患者中,FEAR指数截断值-5.0°预测不稳定的特异度为92.4%,准确度69.4%。

要点

  • FEAR指数截断值-5.0°预测非发育不良人群不稳定的特异度92.4%,准确度69.4%。

核心结论

  • FEAR指数在边缘性发育不良和非发育不良人群中均被验证可改善术前对不稳定患者的识别。

研究设计与样本

  • 诊断性队列研究,证据等级2;连续200例髋关节镜手术患者,术中评估微不稳定,回顾性测量影像学参数。
  • 排除既往骨性手术、同侧开放髋手术或全髋关节置换、骨关节炎(Tönnis分级>1)、中重度髋臼发育不良(LCEA<18°)者。
  • 最终分析150例患者167髋。

主要发现

  • 术中评估稳定96髋(57.5%),微不稳定71髋(42.5%)。
  • 不稳定组股骨髋臼撞击影像学表现较少,边缘性发育不良比例较高。
  • 4个测量角度均有极好的观察者间一致性。

关键数值与推荐

  • 微不稳定基于既往发表标准术中诊断。
  • 测量参数包括Wiberg外侧中心边缘角(LCEA)、Tönnis角、骺板瘢痕角、FEAR指数。
  • FEAR指数截断值-5.0°预测非发育不良人群不稳定的特异度92.4%,准确度69.4%。

临床怎么用

  • FEAR指数可用于术前辅助识别微不稳定患者,尤其在边缘性发育不良和非发育不良人群中。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Atraumatic hip instability, or microinstability, is a challenging diagnosis for clinicians to make. Several radiographic parameters have been proposed to help identify patients with instability as a means to direct treatment. The Femoro-epiphyseal Acetabular Roof (FEAR) index was recently offered as a parameter to predict instability in a borderline dysplastic population. PURPOSE: To evaluate the FEAR index in a series of predominantly nondysplastic patients undergoing hip arthroscopic surgery to determine if it can accurately predict patients with diagnosed microinstability at the time of surgery. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: A consecutive series of 200 patients undergoing hip arthroscopic surgery were evaluated for microinstability intraoperatively. Microinstability was diagnosed based on previously published criteria. Retrospectively, radiographic parameters were measured including the lateral center edge angle of Wiberg (LCEA), Tönnis angle, physeal scar angle, and FEAR index. Patients were excluded if they previously had any type of bony procedures performed, underwent prior open hip surgery or total hip arthroplasty of the ipsilateral hip, had osteoarthritis (Tönnis grade >1), or had any radiographic features of moderate-to-severe acetabular dysplasia including an LCEA <18°. RESULTS: After applying exclusion criteria, 167 hips in 150 patients were analyzed. Based on an intraoperative assessment, 96 hips (57.5%) were considered stable, and 71 hips (42.5%) had signs of microinstability (unstable group). Patients in the unstable group had fewer radiographic findings of femoroacetabular impingement and higher rates of borderline dysplasia. All 4 measured angles were found to have excellent interobserver agreement. The FEAR index was significantly more positive in the unstable group compared with the stable group (-7.8° vs -11.3°, respectively; P = .004). A more positive FEAR index was also found in patients meeting intraoperative criteria for instability, with the exception of chondral wear pattern. Unstable nondysplastic patients (LCEA ≥25°, Tönnis angle ≤10°) also were found to have higher FEAR index values (-9.0° vs -12.0°, respectively; P = .012). A FEAR index cut-off of -5.0° was associated with a specificity of 92.4% and accuracy of 69.4% for predicting instability in a nondysplastic population. CONCLUSION: The FEAR index was validated to improve the recognition of unstable patients preoperatively across a population with both borderline dysplastic and nondysplastic features.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Truntzer JN, Hoppe DJ, Shapiro LM, et al. Can the FEAR Index Be Used to Predict Microinstability in Patients Undergoing Hip Arthroscopic Surgery? Am J Sports Med. 2019. PMID: 31603694. doi:10.1177/0363546519876105

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。