术者手术量与培训状态对全膝关节置换术后假体力线的影响
这项回顾性多中心研究分析了1570例初次全膝关节置换术,按术者年手术量(≥50例为高量,<50例为低量)和培训状态(受训者或非受训者)分组,比较术后股骨远端内侧角、胫骨近端内侧角和胫骨后倾角的离群值比例。高量非受训者组的离群值和严重离群值比例均显著低于低量非受训者组和受训者组;低量非受训者组与受训者组多数指标无显著差异。结论认为低手术量和受训状态是力线离群的风险因素。
要点
- 高量非受训者组胫骨近端内侧角离群比例5.3%显著低于低量非受训者组17.4%(p<0.001)。
- 高量非受训者组总离群比例11.8%显著低于受训者组22.3%(p<0.001)。
- 低量非受训者组与受训者组多数力线指标无显著差异。
核心结论
- 低手术量和受训状态是初次全膝关节置换术中立线离群和严重离群的风险因素。
- 受训者的表现与低量非受训者相似,且不劣于低量非受训者。
- 即使在高量非受训者这一表现最佳的队列中,力线离群比例仍然较高。
研究设计与样本
- 回顾性多中心研究,对在美国和英国4个私立学术中心及公立中心施行的1570例初次全膝关节置换术进行影像学分析。
- 术者按年手术量分为高量(≥50例/年)和低量(<50例/年),按培训状态分为受训者(在主治医师监督下的 fellow/住院医师)和非受训者(主治医师)。
- 据此定义3组:高量非受训者、低量非受训者和受训者。
- 术后影像学测量股骨远端内侧角(DFA)、胫骨近端内侧角(PTA)和胫骨后倾角(PSA)。
主要发现
- 单因素分析中,高量非受训者组相比低量非受训者组,PTA离群比例5.3% vs 17.4%、PSA离群比例17.4% vs 28.3%、总离群比例11.8% vs 20.7%均显著更低(均p<0.001)。
- 高量非受训者组相比低量非受训者组,DFA离群1.9% vs 6.5%、PTA严重离群1.8% vs 5.7%、PSA严重离群5.5% vs 12.6%、总严重离群3.1% vs 8.3%均显著更低(均p<0.001)。
- 高量非受训者组相比受训者组,DFA离群12.6% vs 21.6%、PTA离群5.3% vs 12.0%、PSA离群17.4% vs 33.3%、总离群11.8% vs 22.3%均显著更低(均p<0.001)。
- 高量非受训者组相比受训者组,DFA严重离群1.9% vs 3.9%(p=0.027)、PSA严重离群5.5% vs 12.6%(p<0.001)、总严重离群3.1% vs 6.4%(p=0.004)均显著更低。
- 低量非受训者组与受训者组相比,除PTA离群17.4% vs 12.0%(p=0.041)和PTA严重离群5.7% vs 2.6%(p=0.033)外,其余指标无显著差异;校正患者年龄、体重指数和个体术者后的多因素分析结果相似。
关键数值与推荐
- 高量定义为≥50例全膝关节置换术/年,低量定义为<50例/年。
- DFA离群定义为超出5°±3°外翻范围;PTA离群定义为偏离中立轴>±3°;PSA离群定义为后稳定型假体<0°或>5°屈曲,或保留交叉韧带型假体<0°或>7°屈曲。
- 严重离群定义为超出上述范围>±2°。
临床怎么用
- 术者年手术量≥50例与初次全膝关节置换术后力线离群和严重离群比例更低相关。
- 受训者施行的初次全膝关节置换术力线结果与低量非受训者相似,不劣于低量非受训者。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Implant malalignment may predispose patients to prosthetic failure following total knee arthroplasty (TKA). A more thorough understanding of the surgeon-specific factors that contribute to implant malalignment following TKA may uncover actionable strategies for improving implant survival. The purpose of this study was to determine the impact of surgeon volume and training status on malalignment. METHODS: In this retrospective multicenter study, we performed a radiographic analysis of 1,570 primary TKAs performed at 4 private academic and state-funded centers in the U.S. and U.K. Surgeons were categorized as high-volume (≥50 TKAs/year) or low-volume (<50 TKAs/year), and as a trainee (fellow/resident under the supervision of an attending surgeon) or a non-trainee (attending surgeon). On the basis of these designations, 3 groups were defined: high-volume non-trainee, low-volume non-trainee, and trainee. The postoperative medial distal femoral angle (DFA), medial proximal tibial angle (PTA), and posterior tibial slope angle (PSA) were radiographically measured. Outlier measurements were defined as follows: DFA, outside of 5° ± 3° of valgus; PTA, >±3° deviation from the neutral axis; and PSA, <0° or >7° of flexion for cruciate-retaining or <0° or >5° of flexion for posterior-stabilized TKAs. "Far outliers" were defined as measurements falling >± 2° outside of these ranges. The proportions of outliers were compared between the groups using univariate and multivariate analyses. RESULTS: When comparing the high and low-volume non-trainee groups using univariate analysis, the proportions of knees with outlier measurements for the PTA (5.3% versus 17.4%) and PSA (17.4% versus 28.3%) and the proportion of total outliers (11.8% versus 20.7%) were significantly lower in the high-volume group (all p < 0.001). The proportions of DFA (1.9% versus 6.5%), PTA (1.8% versus 5.7%), PSA (5.5% versus 12.6%), and total far outliers (3.1% versus 8.3%) were also significantly lower in the high-volume non-trainee group (all p < 0.001). Compared with the trainee group, the high-volume non-trainee group had significantly lower proportions of DFA (12.6% versus 21.6%), PTA (5.3% versus 12.0%), PSA (17.4% versus 33.3%), and total outliers (11.8% versus 22.3%) (all p < 0.001) as well as DFA (1.9% versus 3.9%; p = 0.027), PSA (5.5% versus 12.6%; p < 0.001), and total far outliers (3.1% versus 6.4%; p = 0.004). No significant differences were identified when comparing the low-volume non-trainee group and the trainee group, with the exception of PTA outliers (17.4% versus 12.0%; p = 0.041) and PTA far outliers (5.7% versus 2.6%; p = 0.033). Findings from multivariate analysis accounting for the effects of patient age, body mass index, and individual surgeon demonstrated similar results. CONCLUSIONS: Low surgical volume and trainee status were risk factors for outlier and far-outlier malalignment in primary TKA, even when accounting for differences in individual surgeon and patient characteristics. Trainee surgeons performed similarly, and certainly not inferiorly, to low-volume non-trainee surgeons. Even among high-volume non-trainees, the best-performing cohort in our study, the proportion of TKA alignment outliers was still high. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
引用
- Kazarian GS, Lawrie CM, Barrack TN, et al. The Impact of Surgeon Volume and Training Status on Implant Alignment in Total Knee Arthroplasty. J Bone Joint Surg Am. 2019. PMID: 31577676. doi:10.2106/JBJS.18.01205
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。