荷兰全髋与全膝关节置换术后翻修率的医院间差异:导向质量改进举措
THA和TKA的1年翻修率均存在较大医院间差异,多数离群医院可识别出特定翻修指征,THA总体翻修的排名可靠性为62%(中等),TKA为46%(低)。
要点
- THA总体翻修排名可靠性62%(中等),TKA为46%(低)。
- 7家TKA医院为负向离群(中位O/E比2.3,IQR 2.2-2.8),2家多年离群。
核心结论
- 初次THA和TKA术后1年翻修率存在较大的医院间差异。
- 多数离群医院可识别出特定翻修指征,尤其THA,可作为质量改进的起点。
研究设计与样本
- 采用漏斗图(95%控制限)基于1年或3年数据识别离群医院,期望数基于患者构成用logistic回归模型计算。
- 使用固定效应和随机效应模型评估排名可靠性(rankability),即真实医院差异解释的总变异百分比。
主要发现
- 7家TKA医院为负向离群,中位O/E比2.3(IQR 2.2-2.8),其中2家多年离群;假体周围感染2家、技术失败1家。
- THA总体翻修排名可靠性62%(中等),TKA为46%(低)。
关键数值与推荐
- THA负向离群医院中位O/E比1.9(IQR 1.5-2.5),TKA为2.3(IQR 2.2-2.8)。
- THA总体翻修排名可靠性62%(中等),TKA为46%(低)。
临床怎么用
- 医院间1年翻修率差异及特定翻修指征的识别可作为质量改进举措的起点。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Variation in 1-year revision rates between Dutch hospitals after primary total hip and knee arthroplasty (THA and TKA) may direct quality-improvement initiatives if this variation accurately reflects true hospital differences. The aim of the present study was to assess the extent of variation, both overall and for specific indications, as well as the statistical reliability of ranking hospitals. METHODS: All primary THAs and TKAs that were performed between January 2014 and December 2016 were included. Observed/expected (O/E) ratios regarding 1-year revision rates were depicted in a funnel plot with 95% control limits to identify outliers based on 1 or 3 years of data, both overall and by specific indication for revision. The expected number was calculated on the basis of patient mix with use of logistic regression models. The statistical reliability of ranking hospitals (rankability) on these outcomes indicates the percentage of total variation that is explained by "true" hospital differences rather than chance. Rankability was evaluated using fixed and random effects models, for overall revisions and specific indications for revision, including 1 versus 3 years of data. RESULTS: The present study included 86,468 THAs and 73,077 TKAs from 97 and 98 hospitals, respectively. Thirteen hospitals performing THAs were identified as negative outliers (median O/E ratio, 1.9; interquartile range [IQR], 1.5-2.5), with 5 hospitals as outliers in multiple years. Eight negative outliers were identified for periprosthetic joint infection; 4, for dislocation; and 2, for prosthesis loosening. Seven hospitals performing TKAs were identified as negative outliers (median O/E ratio, 2.3; IQR, 2.2-2.8), with 2 hospitals as outliers in multiple years. Two negative outlier hospitals were identified for periprosthetic joint infection and 1 was identified for technical failures. The rankability for overall revisions was 62% (moderate) for THA and 46% (low) for TKA. CONCLUSIONS: There was large between-hospital variation in 1-year revision rates after primary THA and TKA. For most outlier hospitals, a specific indication for revision could be identified as contributing to worse performance, particularly for THA; these findings are starting points for quality-improvement initiatives.
引用
- van Schie P, van Steenbergen LN, van Bodegom-Vos L, et al. Between-Hospital Variation in Revision Rates After Total Hip and Knee Arthroplasty in the Netherlands: Directing Quality-Improvement Initiatives. J Bone Joint Surg Am. 2020. PMID: 31658206. doi:10.2106/JBJS.19.00312
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。