干骺端袖套在翻修全膝关节置换术中提供可靠固定并显示优良中长期假体生存率
该研究回顾性分析319例使用干骺端袖套的翻修全膝关节置换术,平均随访91个月,73例随访超过10年。假体生存率3年99.1%、5年98.7%、10年97.8%,无袖套因无菌性松动翻修。影像学显示胫骨袖套透亮线2.8%、股骨袖套2.7%,均未进展且未翻修;3.7%胫骨袖套下沉>1mm但均稳定且未翻修。
要点
- 干骺端袖套翻修TKA的10年假体生存率为97.8%。
- 无干骺端袖套因无菌性松动而翻修。
- 胫骨袖套透亮线2.8%、股骨袖套2.7%,均未进展或翻修。
核心结论
- 在翻修TKA中使用干骺端袖套与优良的中长期生存率和影像学结果相关。
研究设计与样本
- 回顾性分析319例使用干骺端袖套的翻修TKA,来自前瞻性收集的数据库。
- 随访至少2年,平均随访91个月,73例患者随访超过10年。
主要发现
- 假体生存率3年99.1%、5年98.7%、10年97.8%。
- 无干骺端袖套因无菌性松动而翻修。
- 最终影像学复查显示胫骨袖套透亮线2.8%、股骨袖套2.7%,均未进展且未翻修。
- 约3.7%的胫骨袖套较术后即刻X线片下沉超过1mm,但均稳定且未翻修。
关键数值与推荐
- 假体生存率:3年99.1%、5年98.7%、10年97.8%。
- 胫骨袖套透亮线发生率2.8%,股骨袖套透亮线发生率2.7%。
- 胫骨袖套下沉超过1mm的发生率约3.7%。
临床怎么用
- 原文未报告临床实践建议。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Addressing bone loss and securing implant fixation can be challenging in revision total knee arthroplasty (TKA). We present the results of a large series of revision TKAs using a metaphyseal sleeve. METHODS: We retrospectively analyzed 319 revision TKAs with the use of a metaphyseal sleeve that had been followed up for at least 2 years, using a prospectively collected database. The mean follow-up was 91 months, and 73 patients were followed up for more than 10 years. RESULTS: Implant survivorship was 99.1% at 3 years, 98.7% at 5 years, and 97.8% at 10 years. No metaphyseal sleeve was revised for aseptic loosening. Final radiographic review showed that there were radiolucent lines present in 2.8% of tibial sleeves and 2.7% of femoral sleeves; none of these had progressed and none were revised. About 3.7% of tibial sleeves subsided more than 1 mm compared with the immediate postoperative X-ray but all stabilized and none were revised. CONCLUSION: Use of a metaphyseal sleeve in revision TKA is associated with excellent survivorship and radiographic outcome in the medium to long term.
引用
- Bloch BV, Shannak OA, Palan J, et al. Metaphyseal Sleeves in Revision Total Knee Arthroplasty Provide Reliable Fixation and Excellent Medium to Long-Term Implant Survivorship. J Arthroplasty. 2019. PMID: 31606290. doi:10.1016/j.arth.2019.09.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。