文献速递关节外科

窄股骨假体对后稳定型全膝关节置换术中软组织平衡的影响

Influence of Narrow Femoral Implants on Intraoperative Soft Tissue Balance in Posterior-Stabilized Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2019-09-05

本研究纳入30例接受后稳定型全膝关节置换术的内翻性骨关节炎患者,使用无影像导航系统比较标准与窄股骨试模的术中软组织平衡。结果显示窄试模组在多数屈曲角度下关节间隙显著大于标准试模组,且窄假体队列中窄试模组在45°、60°和120°屈曲时内翻角度显著更大。结论认为股骨假体的内外侧尺寸和体积可能影响软组织平衡,当选择窄假体以避免假体悬突时影响可能更大。

要点

  • 窄试模组在多数测量屈曲角度下关节间隙显著大于标准试模组(P<.05)。
  • 窄假体队列中,窄试模组在45°、60°和120°屈曲时内翻角度显著大于标准试模组(P<.05)。
  • 股骨假体内外侧尺寸和体积可能影响PS TKA术中软组织平衡。

核心结论

  • 股骨假体的内外侧尺寸和体积可能影响后稳定型全膝关节置换术中的术中软组织平衡。
  • 当选择窄假体以避免假体悬突时,这种影响可能更大。

研究设计与样本

  • 纳入30例连续的内翻性骨关节炎患者,接受使用无影像导航系统的后稳定型全膝关节置换术。
  • 插入标准与窄股骨试模并测量软组织平衡。
  • 根据实际植入的股骨假体进行亚组分析,以评估窄假体对软组织平衡的影响。

主要发现

  • 窄试模组在除60°外的所有测量屈曲角度下关节间隙显著大于标准试模组(P<.05)。
  • 标准假体队列中,窄试模组在30°、120°和135°屈曲时关节间隙显著大于标准试模组(P<.05)。
  • 窄假体队列中,窄试模组在除0°和60°外的所有测量屈曲角度下关节间隙显著大于标准试模组(P<.05)。
  • 窄试模组在45°和60°屈曲时内翻韧带平衡显著大于标准试模组(P<.05)。
  • 标准假体的内翻角度在两组间相当;窄假体中窄试模组在45°、60°和120°屈曲时内翻角度显著大于标准试模组(P<.05)。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Narrow femoral implants were developed to improve fit and prevent overhang in primary total knee arthroplasty (TKA). We compared intraoperative soft tissue balance between standard and narrow implants in posterior-stabilized (PS) TKA. METHODS: We enrolled 30 consecutive patients with varus osteoarthritis undergoing PS TKA using an image-free navigation system. Standard and narrow femoral trial implants were inserted, and their soft tissue balance was measured. Subgroup analysis, based on the actual implanted femoral implant, was performed to assess the influence of narrow implants on soft tissue balance. RESULTS: Narrow trial group had significantly larger joint component gaps than standard trial group at all measured flexion angles, except at 60° (P < .05). For the standard implant cohort, narrow trial group had significantly larger joint component gaps than standard trial group at 30°, 120°, and 135° flexion (P < .05). For the narrow implant cohort, narrow trial group had significantly larger joint component gaps than standard trial group at all measured flexion angles, except at 0° and 60° (P < .05). Narrow trial group had significantly larger varus ligament balance than standard trial group at 45° and 60° flexion (P < .05). The varus angles for standard implants were comparable between groups; however, narrow trial group had significantly larger varus angles for narrow implants than standard trial group at 45°, 60°, and 120° flexion (P < .05). CONCLUSION: The medial-lateral dimension and volume of the femoral component may influence intraoperative soft tissue balance in PS TKA. The effects may be greater when narrow implants are selected to avoid component overhang.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Ishida K, Shibanuma N, Sasaki H, et al. Influence of Narrow Femoral Implants on Intraoperative Soft Tissue Balance in Posterior-Stabilized Total Knee Arthroplasty. J Arthroplasty. 2019. PMID: 31604592. doi:10.1016/j.arth.2019.08.055

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。