文献速递脊柱外科

高危脊柱手术经颅电刺激运动诱发电位监测的不良事件:前瞻性多中心研究

Adverse Events Related to Transcranial Electric Stimulation for Motor-evoked Potential Monitoring in High-risk Spinal Surgery.
PubMed 文献 · Spine (Phila Pa 1976) · 2019-01-01

该前瞻性多中心研究分析了2010至2016年间11个脊柱中心2643例高危脊柱手术中经颅电刺激运动诱发电位监测的数据。Tc(E)-MEPs波幅下降70%作为中断手术的报警标准,预测术后运动缺损的敏感性为93.5%、特异性为91.0%。非神经性不良事件发生率为0.64%,最常见为咬伤(0.57%),作者建议使用软咬块并频繁评估口腔内完整性。

要点

  • Tc(E)-MEPs波幅下降70%报警标准预测术后运动缺损敏感性93.5%、特异性91.0%。
  • 非神经性不良事件发生率0.64%,咬伤最常见(0.57%),含舌裂伤11例、唇裂伤2例、牙齿断裂2例。
  • 非神经性不良事件未显著影响IOM评估准确性,手术时间和失血量未显著影响不良事件发生。

核心结论

  • Tc(E)-MEPs监测期间非神经性不良事件虽罕见但存在,尤其是咬伤,需使用软咬块并频繁评估麻醉患者口腔内完整性以最小化此类并发症。

研究设计与样本

  • 前瞻性多中心研究,分析2010至2016年11个脊柱中心2643例接受术中Tc(E)-MEPs监测的高危脊柱手术患者数据。

主要发现

  • Tc(E)-MEPs波幅下降70%报警标准预测术后运动缺损敏感性93.5%、特异性91.0%、假阳性率8.2%、假阴性率0.3%。
  • 非神经性不良事件发生于17例(0.64%)患者,最常见为咬伤(0.57%),包括舌裂伤11例、唇裂伤2例、牙齿断裂2例。
  • 4例(0.15%)舌裂伤需缝合手术修复,2例牙齿断裂需牙科治疗。
  • 1例患者出现与TES部位对应的脱发,1例经鼻放置电极后发生严重鼻出血并自行缓解。
  • 非神经性不良事件未显著影响IOM评估准确性,手术时间和失血量未显著影响不良事件发生。

关键数值与推荐

  • Tc(E)-MEPs波幅下降70%为中断手术的报警标准。
  • 该报警标准预测术后运动缺损:敏感性93.5%、特异性91.0%、假阳性率8.2%、假阴性率0.3%。

临床怎么用

  • 术者和监测团队应考虑到TES-IOM期间非神经性不良事件(尤其是咬伤)的可能性,尽管罕见。
  • 使用软咬块并频繁评估麻醉患者口腔内完整性可最小化此类并发症。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Prospective multicenter study. OBJECTIVE: The aim of this study was to study the incidence of nonneurologic adverse events related to transcranial electric stimulation (TES) for intraoperative spinal cord monitoring (IOM) with motor-evoked potentials (MEPs) (Tc(E)- MEPs) and determine the need for safety precautions. SUMMARY OF BACKGROUND DATA: Tc(E)-MEPs monitoring requires high-voltage multipulse TES that causes widespread muscle contraction and movement. Improved awareness of TES-induced movement-related adverse events is needed. METHODS: We analyzed data from 2643 patients who underwent high-risk spinal surgery with intraoperative Tc(E)-MEPs at 11 spinal centers from 2010 to 2016. Information about neurologic and non-neurologic postoperative complications was collected, including type of surgical procedure, operative time, estimated blood loss, and treatment for postoperative adverse events. RESULTS: A 70% drop in Tc(E)-MEPs amplitude, which was the alarm criterion to interrupt surgery, predicted postoperative motor deficits with 93.5% sensitivity, 91.0% specificity, a false-positive rate of 8.2%, and a false-negative rate of 0.3%. Non-neurologic adverse events developed in 17 (0.64%) patients and were most commonly because of bite injuries (0.57%), including 11 cases of tongue laceration, two cases of lip laceration, and two cases of tooth breakage. Four (0.15%) tongue lacerations required surgical repair with sutures and two tooth breakages required dental treatment. One patient had hair loss corresponding to the TES site. One patient, who underwent additional IOM with transpharyngeal stimulation, had severe nasal hemorrhage following electrode placement by nasal route, which resolved spontaneously. Non-neurologic adverse events did not significantly affect the accuracy of IOM assessment. Neither operative times nor blood loss significantly influenced the occurrence of adverse events. CONCLUSION: During TES-IOM, both the surgeon and monitoring team must consider the possibility-although rare-of non-neurologic adverse events, particularly bite injuries. Such complications can be minimized by using a soft bite-block and frequently evaluating the intraoral integrity of the anesthetized patient. LEVEL OF EVIDENCE: 4.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Yoshida G, Imagama S, Kawabata S, et al. Adverse Events Related to Transcranial Electric Stimulation for Motor-evoked Potential Monitoring in High-risk Spinal Surgery. Spine (Phila Pa 1976). 2019. PMID: 31589200. doi:10.1097/BRS.0000000000003115

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。