文献速递脊柱外科创伤骨科

机器人辅助颈椎螺钉置入提高颈椎手术准确性:一项前瞻性随机对照研究

Improved Accuracy of Cervical Spinal Surgery With Robot-Assisted Screw Insertion: A Prospective, Randomized, Controlled Study.
PubMed 文献 · Spine (Phila Pa 1976) · 2020-01-01

该前瞻性随机对照试验将135例需螺钉固定的新诊断颈椎疾病患者随机分配至机器人辅助组或传统透视辅助组,最终127例接受干预(机器人组61例,传统组66例)。机器人辅助组螺钉置入准确性优于传统透视辅助组,且术中出血量和术后住院时间更少,但两组手术时长无显著差异。

要点

  • 机器人辅助组螺钉置入偏差0.83 [0.44, 1.29] mm,传统透视辅助组1.79 [1.41, 2.50] mm,P<0.001。
  • Gertzbein and Robbins分级两组间差异显著(P<0.001)。
  • 机器人辅助组术中出血量200 [50, 375] mL,传统组350 [100, 500] mL,P=0.002。

核心结论

  • 在本前瞻性随机对照试验中,机器人辅助技术的准确性和临床结局倾向于优于传统透视辅助技术。

研究设计与样本

  • 前瞻性、随机、对照试验,将135例新诊断颈椎疾病需螺钉固定的患者随机分配至机器人辅助或传统透视辅助颈椎手术。

主要发现

  • 共127例患者接受干预(机器人辅助组61例,传统透视辅助组66例),两组基线特征包括螺钉类型相似。
  • 共计划并置入390枚颈椎螺钉,94.9%可接受。
  • 机器人辅助组螺钉置入偏差0.83 [0.44, 1.29] mm,传统透视辅助组1.79 [1.41, 2.50] mm,P<0.001。
  • Gertzbein and Robbins分级两组间差异显著(P<0.001)。
  • 机器人辅助组术中出血量200 [50, 375] mL,传统透视辅助组350 [100, 500] mL,P=0.002;术后住院时间机器人辅助组更短(P=0.021)。

关键数值与推荐

  • 主要结局为计划轨迹与实际螺钉位置之间的偏差。
  • 螺钉置入准确性以偏差值表示:机器人辅助组0.83 [0.44, 1.29] mm vs 传统透视辅助组1.79 [1.41, 2.50] mm,P<0.001。
  • Gertzbein and Robbins分级两组间P<0.001。
  • 术中出血量:机器人辅助组200 [50, 375] mL vs 传统透视辅助组350 [100, 500] mL,P=0.002。
  • 手术时长两组无显著差异(P=0.525);术后住院时间机器人辅助组更短(P=0.021)。

临床怎么用

  • 对于需螺钉固定的颈椎疾病患者,机器人辅助技术可提高螺钉置入准确性并减少术中出血量。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Prospective, randomized, controlled trial. OBJECTIVE: To compare robot-assisted and conventional implantation techniques by evaluating the accuracy and safety of implanting screws in cervical vertebrae. SUMMARY OF BACKGROUND DATA: Cervical spinal surgery is difficult and dangerous as screw misplacement might lead not only to decreased stability but also neurological, vascular, and visceral injuries. A new robot-assisted surgical procedure has been introduced to improve the accuracy of implant screw positioning. METHODS: We randomly assigned 135 patients with newly diagnosed cervical spinal disease and who required screw fixation using either robot-assisted or conventional fluoroscopy-assisted cervical spinal surgery. The primary outcomes were the discrepancies between the planned trajectories and the actual screw positions. RESULTS: Altogether, 127 patients underwent the assigned intervention (61 robot-assisted and 66 conventional fluoroscopy-assisted). The baseline characteristics including the screw types, were similar in the two groups. Altogether, 390 screws were planed and placed in the cervical vertebrae, and 94.9% were acceptable. The robot-assisted group had a better screw placement accuracy than the conventional fluoroscopy-assisted group with associated P values <0.001 (0.83 [0.44, 1.29] vs. 1.79 [1.41, 2.50] mm). The Gertzbein and Robbins scales also showed a significant difference between the two groups (P < 0.001). Furthermore, the robot-assisted group experienced significantly less blood loss during surgery than the conventional fluoroscopy-assisted group (200 [50, 375] vs. 350 [100, 500] mL; P = 0.002) and shorter length of stay after surgery (P = 0.021). These two groups did not differ significantly regarding the duration of the operation (P = 0.525). Neurological injury occurred in one case in the conventional fluoroscopy-assisted group. CONCLUSION: The accuracy and clinical outcomes of cervical spinal surgery using the robot-assisted technique tended to be superior to those with the conventional fluoroscopy-assisted technique in this prospective, randomized, controlled trial. LEVEL OF EVIDENCE: 2.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Fan M, Liu Y, He D, et al. Improved Accuracy of Cervical Spinal Surgery With Robot-Assisted Screw Insertion: A Prospective, Randomized, Controlled Study. Spine (Phila Pa 1976). 2020. PMID: 31568094. doi:10.1097/BRS.0000000000003258

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。