超短解剖型非骨水泥股骨柄与陶瓷对陶瓷界面在特发性或乙醇性股骨头坏死中的长期结果
平均随访14.7年,股骨柄无菌性松动翻修4例(1%),髋臼组件翻修1例(0.3%),股骨柄生存率99.0%(95%CI 94-100),髋臼组件生存率99.4%(95%CI 95-100)。
要点
- 平均随访14.7年,股骨柄生存率99.0%(95%CI 94-100),髋臼组件99.4%(95%CI 95-100)。
- 4例股骨柄(1%)因无菌性松动翻修,1例髋臼组件(0.3%)因复发性脱位翻修。
- 末次随访平均Harris髋关节评分94分,WOMAC评分12分,UCLA活动评分8分。
核心结论
- 超短近端负载解剖型非骨水泥股骨柄联合陶瓷对陶瓷界面在长期随访中显示优异的免于无菌性松动的生存率和良好的临床结果。
研究设计与样本
- 所有患者术前及末次随访接受髋臼和股骨近端双能X线吸收测定法扫描,末次随访接受CT扫描。
主要发现
- 末次随访平均Harris髋关节评分为94分,WOMAC评分为12分,UCLA活动评分为8分。
- 4例股骨柄(1%)因无菌性松动翻修,1例髋臼组件(0.3%)因复发性脱位翻修。
- 无髋因摩擦音或咔嗒声翻修。
- 股骨柄生存率为99.0%(95%CI 94-100),髋臼组件生存率为99.4%(95%CI 95-100),随访时间14.7年。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Long-term result of the ultra-short anatomic cementless stem in the patients with idiopathic or ethanol-induced osteonecrosis of the femoral head has not been assessed. The aim of this study is to evaluate the long-term clinical, radiographic, computed tomography scan, and dual-energy X-ray absorptiometry scanning results, and survivorship of this specific femoral stem in patients with idiopathic or ethanol-induced femoral head osteonecrosis. METHODS: Two hundred fifty-six patients (335 hips) with an average age of 49.8 years (range 20-63) were enrolled in the current study. All patients underwent dual-energy X-ray absorptiometry scanning of the acetabulum and proximal femur preoperatively and at final follow-up. Computed tomography scan was obtained in all patients at final follow-up. The mean follow-up was 14.7 years (range 13-16). RESULTS: At final follow-up, the average Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index score, and University of California, Los Angeles activity score were 94 points, 12 points, and 8 points, respectively. Four stems (1%) underwent revision for aseptic loosening. One acetabular component (0.3%) was revised for recurrent dislocation. No hip was revised for squeaking or clicking sound. Survivorship of the femoral stem was 99.0% (95% confidence interval 94-100) and that of the acetabular component was 99.4% (95% confidence interval 95-100) at 14.7 years. CONCLUSION: Ultra-short proximal loading anatomic uncemented femoral stems with ceramic-on-ceramic bearings have excellent survivorship free from aseptic loosening and good clinical results at long term. LEVEL OF EVIDENCE: Level IV.
引用
- Kim YH, Park JW. Ultra-Short Anatomic Uncemented Femoral Stem and Ceramic-on-Ceramic Bearing in Patients With Idiopathic or Ethanol-Induced Femoral Head Osteonecrosis. J Arthroplasty. 2019. PMID: 31542265. doi:10.1016/j.arth.2019.08.047
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。