文献速递关节外科创伤骨科

复杂翻修全髋中骨水泥固定双动杯置入金属环的10年以上低翻修率

Low Revision Rates at More Than 10 Years for Dual-Mobility Cups Cemented Into Cages in Complex Revision Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2019-09-05

该回顾性研究纳入77例Paprosky≥2C严重髋臼骨缺损的翻修全髋关节置换病例,均采用双动杯骨水泥固定于金属加固环。平均随访10.7年,因无菌性髋臼松动再手术3例(3.9%),脱位7例(9.45%),仅1例慢性不稳(1.3%),10年杯生存率96.1%。

要点

  • Paprosky≥2C骨缺损翻修全髋中,双动杯骨水泥固定于金属环10年杯生存率96.1%。
  • 无菌性髋臼松动再手术率3.9%,慢性不稳仅1.3%。
  • 脱位发生率9.45%,但仅1例发展为慢性不稳。

核心结论

  • 在复杂髋臼骨缺损的翻修全髋关节置换中,将双动杯骨水泥固定于金属环,10年时因髋臼松动或慢性不稳的翻修率低。

研究设计与样本

  • 回顾性研究,纳入77例严重髋臼骨缺损(Paprosky≥2C)的翻修全髋关节置换病例,均使用双动杯(NOVAE STICK)骨水泥固定于金属笼(Kerboull cross、Burch-Schneider或ARM环),术前及末次随访进行临床评分和影像学评估。

主要发现

  • 平均随访10.7年[2.1-16.2],3例(3.9%)因无菌性髋臼松动再手术,发生时间为9.6年[7-12]。
  • 7例(9.45%)发生假体脱位,仅1例(1.3%)存在慢性不稳。
  • 10年杯生存率为96.1%。
  • 未发现进行性放射透亮线,91%的患者植骨整合满意。

关键数值与推荐

  • 主要终点为因无菌性松动或反复脱位进行的翻修手术。
  • 10年杯生存率96.1%。
  • 无菌性髋臼松动再手术率3.9%,慢性不稳发生率1.3%,脱位发生率9.45%。
  • 植骨整合满意率91%。

临床怎么用

  • 对于Paprosky≥2C严重髋臼骨缺损的翻修全髋关节置换,采用双动杯骨水泥固定于金属环可能获得低翻修率和低慢性不稳率。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Instability and aseptic loosening are the two main complications after revision total hip arthroplasty (rTHA). Dual-mobility (DM) cups were shown to counteract implant instability during rTHA. To our knowledge, no study evaluated the 10-year outcomes of rTHA using DM cups, cemented into a metal reinforcement ring, in cases of severe acetabular bone loss. We hypothesized that using a DM cup cemented into a metal ring is a reliable technique for rTHA at 10 years, with few revisions for acetabular loosening and/or instability. METHODS: This is a retrospective study of 77 rTHA cases with severe acetabular bone loss (Paprosky ≥ 2C) treated exclusively with a DM cup (NOVAE STICK; Serf, Décines-Charpieu, France) cemented into a cage (Kerboull cross, Burch-Schneider, or ARM rings). Clinical scores and radiological assessments were performed preoperatively and at the last follow-up. The main endpoints were revision surgery for aseptic loosening or recurring dislocation. RESULTS: With a mean follow-up of 10.7 years [2.1-16.2], 3 patients were reoperated because of aseptic acetabular loosening (3.9%) at 9.6 years [7-12]. Seven patients (9.45%) dislocated their hip implant, only 1 suffered from chronic instability (1.3%). Cup survivorship was 96.1% at 10 years. No sign of progressive radiolucent lines were found and bone graft integration was satisfactory for 91% of the patients. CONCLUSION: The use of a DM cup cemented into a metal ring during rTHA with complex acetabular bone loss was associated with low revision rates for either acetabular loosening or chronic instability at 10 years.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Sayac G, Neri T, Schneider L, et al. Low Revision Rates at More Than 10 Years for Dual-Mobility Cups Cemented Into Cages in Complex Revision Total Hip Arthroplasty. J Arthroplasty. 2019. PMID: 31543421. doi:10.1016/j.arth.2019.08.058

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。