全膝关节置换术后第1天给予全身性类固醇对疼痛和恶心的疗效:一项随机对照研究
该随机对照研究将行全膝关节置换术(TKA)的患者分为四组:对照组(生理盐水)、组1(术前1小时静脉给予地塞米松10 mg)、组2(术后24小时静脉给予地塞米松0.1 mg/kg)、组3(术后24小时静脉给予地塞米松0.2 mg/kg),每组44-46例。主要结局为疼痛和恶心视觉模拟评分(VAS)。结果显示,组1仅在术后24小时内疼痛和恶心VAS评分低于对照组(P<.01);组2和组3在术后48小时疼痛和恶心VAS评分低于对照组和组1(P<.01),且术后48小时内镇痛药和止吐药使用显著少于对照组。作者建议在术后1天额外给予地塞米松。
要点
- 术前1小时静脉给予地塞米松10 mg仅在术后24小时内降低疼痛和恶心VAS评分(P<.01)。
- 术后24小时静脉给予地塞米松0.1 mg/kg或0.2 mg/kg在术后48小时疼痛和恶心VAS评分低于对照组和术前给药组(P<.01)。
- 术后24小时给予地塞米松的两组在术后48小时内镇痛药和止吐药使用显著少于对照组。
核心结论
- 术前和术后给予地塞米松对控制疼痛和恶心的效果仅持续24小时;考虑到TKA后严重疼痛和恶心持续超过48小时,作者建议在术后1天额外给予地塞米松。
研究设计与样本
- 随机对照研究,将行TKA的患者随机分为四组:对照组(生理盐水注射)、组1(术前1小时静脉给予地塞米松10 mg)、组2(术后24小时静脉给予地塞米松0.1 mg/kg)、组3(术后24小时静脉给予地塞米松0.2 mg/kg),每组44-46例。
- 证据等级为Level I。
主要发现
- 术后疼痛和恶心在TKA后48小时内持续较高。
- 组1在术后仅24小时内疼痛和恶心VAS评分低于对照组(P<.01)。
- 组2和组3在术后48小时疼痛和恶心VAS评分低于对照组和组1(P<.01)。
- 组2和组3在术后48小时内镇痛药和止吐药使用显著少于对照组。
- C反应蛋白水平和关节活动度无差异,未检测到并发症。
临床怎么用
- 作者建议在术后1天额外给予地塞米松,基于术前和术后给药效果仅持续24小时而严重疼痛和恶心持续超过48小时的观察。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Systemic steroid has been used to control pain and nausea in total knee arthroplasty (TKA), but most studies recommend a single dose administration prior to, or during, surgery. This study aimed to determine the efficacy of administration on 1 day postoperatively. METHODS: Patients who were scheduled to undergo TKA were randomly assigned to the following groups: control group, receiving normal saline injection; group 1, receiving 10 mg dexamethasone intravenously (IV) 1 hour before surgery; group 2, receiving 0.1 mg/kg dexamethasone (IV) 24 hours after surgery; or group 3, receiving 0.2 mg/kg dexamethasone (IV) 24 hours after surgery (n = 44-46 per group). Primary outcomes were pain and nausea visual analogue scale (VAS). Secondary outcomes were analgesic administration, rescue antiemetic administration, C-reactive protein, range of motion, and complications. RESULTS: Postoperative pain and nausea remained high for 48 hours post-TKA. Group 1 had lower pain and nausea VAS scores than did the control group (P < .01) for only 24 hours post-TKA. Groups 2 and 3 had lower pain and nausea VAS scores than did the control group and group 1 (P < .01) 48 hours post-TKA. Analgesic and antiemetic administration were significantly lower in groups 2 and 3 than in the control group during 48 hours after TKA. There were no differences in C-reactive protein level and range of motion, and complications were not detected. CONCLUSION: The effect of preoperative and postoperative administration of dexamethasone for controlling pain and nausea was observed only for 24 hours. Considering that severe pain and nausea persisted for more than 48 hours after TKA, additional administration of dexamethasone at 1 day postoperatively is suggested. LEVEL OF EVIDENCE: Level I.
引用
- Kim JK, Ro DH, Lee HJ, et al. Efficacy of Systemic Steroid Use Given One Day After Total Knee Arthroplasty for Pain and Nausea: A Randomized Controlled Study. J Arthroplasty. 2019. PMID: 31563397. doi:10.1016/j.arth.2019.08.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。