稀释聚维酮碘可防止全关节置换术中无菌水盆污染
本研究为随机对照试验,纳入104例初次全关节置换术患者,比较标准无菌水盆与加入稀释聚维酮碘(0.02%溶液)的无菌水盆的污染率。最终100份术后样本中,聚维酮碘组0份(0.0%)培养阳性,标准无菌水组23份(47.9%)阳性(P < .001)。作者认为该干预简单、低成本且易于实施,是全关节置换术方案的合理补充。
要点
- 聚维酮碘组术后水盆培养阳性0份(0.0%),标准无菌水组23份(47.9%),P < .001。
- 阳性培养最常见菌种为凝固酶阴性葡萄球菌、棒状杆菌和微球菌。
- 培养阳性病例的平均手术时间平均延长11分钟。
核心结论
- 用稀释聚维酮碘(0.02%溶液)处理无菌水盆可消除全关节置换术中的术中水盆污染。
- 作者认为该干预简单、低成本且易于实施,是全关节置换术方案的合理补充。
研究设计与样本
- 随机对照试验,纳入初次全关节置换术患者,分为干预组(标准无菌水盆中加入稀释聚维酮碘)和对照组(标准无菌水盆)。
- 总队列104例患者,于切开时(操作前)和关闭时(操作后)各采集120 mL水盆液体样本,培养并监测48小时,必要时进一步鉴定微生物种属。
主要发现
- 最终100份术后样本中,聚维酮碘组0份(0.0%)阳性,标准无菌水组23份(47.9%)阳性(P < .001)。
- 阳性培养中最常见的菌种为凝固酶阴性葡萄球菌、棒状杆菌和微球菌。
- 培养阳性病例的平均手术时间平均延长11分钟。
临床怎么用
- 作者认为用稀释聚维酮碘(0.02%溶液)处理无菌水盆是全关节置换术方案的合理补充。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Periprosthetic joint infection is a major complication of total joint arthroplasty (TJA). The intraoperative splash basin has been found to be a potential source of contamination. Although consensus recommendations against the use of splash basin have been made, splash basin use continues to be taught and utilized in practice. This study aims to investigate the effect of dilute betadine addition to the sterile water (SW) contents (0.02% solution) of the splash basin on contamination rates. This intervention could preserve the functionality and preferential use of the splash basin. The primary outcome of this study is the rate of splash basin contamination, with secondary outcomes of prevalence of culture speciation and mean operative times association with the rate of positive cultures. METHODS: Patients undergoing primary TJA were enrolled in a randomized controlled trial with assignment to either the intervention/betadine group, in which dilute betadine was added to the standard SW splash basin, or the control/standard SW group. For a total cohort of 104 patients, a 120 mL aliquot sample of basin fluid was collected at incision ("preprocedure") and closure ("postprocedure"). Samples were cultured and monitored for 48 hours for growth, with further testing as necessary to identify microbial speciation. RESULTS: Of the final 100 postprocedure samples, 0 (0.0%) were positive in the betadine group, while there were 23 (47.9%) positive samples in the SW group (P < .001). Of the positive cultures, the most common species grown were coagulase-negative Staphylococcus, Corynebacterium, and Micrococcus. The mean operative time was an average of 11 minutes longer for cases with positive cultures. CONCLUSION: In conclusion, treating SW splash basins with dilute povidone-iodine (0.02% solution) eliminates intraoperative contamination of splash basins in TJA procedures. This intervention is simple, low cost, and readily implementable, making it a reasonable addition to TJA protocols. LEVEL OF EVIDENCE: Level 1, Controlled Laboratory Study.
引用
- Nazal MR, Galloway JL, Dhaliwal KK, et al. Dilute Povidone-Iodine Solution Prevents Intraoperative Contamination of Sterile Water Basins During Total Joint Arthroplasty. J Arthroplasty. 2019. PMID: 31537375. doi:10.1016/j.arth.2019.08.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。