文献速递关节外科

后稳定型与交叉韧带保留型全膝关节置换术后远期接触运动学比较

Comparison of Contact Kinematics in Posterior-Stabilized and Cruciate-Retaining Total Knee Arthroplasty at Long-Term Follow-Up.
PubMed 文献 · J Arthroplasty · 2019-08-06

本研究对42膝(PS与CR各半)在术后5年以上行放射立体测量分析,于0°至100°屈曲多个角度测量接触位置、活动度及髁分离,并记录计时起立行走测试与临床评分。结果显示两型在内外侧髁多个屈曲角度的接触位置存在差异(P < .05),PS组外侧活动度大于CR组(P < .01),PS组计时起立行走测试总时间更快(P = .03),临床评分无差异。作者认为结果提示CR型TKA存在后交叉韧带功能不全,PS型的凸轮/立柱系统可能更好地长期维持膝关节运动学与功能。

要点

  • PS与CR型TKA在内外侧髁多个屈曲角度的接触位置存在差异(P < .05)。
  • PS组外侧活动度大于CR组(P < .01),内侧活动度无差异(P = .89)。
  • PS组计时起立行走测试总时间快于CR组(P = .03),临床评分无差异。

核心结论

  • 作者发现运动学与功能差异倾向于PS型TKA,结果提示CR型TKA存在后交叉韧带功能不全,PS型的凸轮/立柱系统可能更好地长期维持膝关节运动学与功能。

研究设计与样本

  • 共研究42膝,PS与CR型TKA两组数量相等。
  • 患者在0°、20°、40°、60°、80°和100°屈曲角度接受放射立体测量分析成像,测量接触位置、活动度及每侧髁的髁分离。
  • 患者完成计时起立行走功能测试并记录总测试时间,同时收集术前与术后临床结局评分。

主要发现

  • 内外侧髁在多个屈曲角度的接触位置存在差异(P < .05)。
  • 内侧活动度无差异(P = .89),PS型TKA外侧活动度大于CR型TKA(P < .01)。
  • 髁分离频率无差异(P > .99)。
  • PS型TKA与更快的计时起立行走测试总时间相关(P = .03)。
  • 两组术前与术后临床结局评分均无差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is controversy regarding the superiority of posterior-stabilizing (PS) total knee arthroplasty (TKA) and cruciate-retaining (CR) TKA. Substantial work has made comparisons between PS and CR TKA at follow-ups of less than 5 years. It was the goal of the present study to compare the kinematics at greater than 5 years postoperatively between CR and PS TKA, with a secondary goal of comparing patient function. METHODS: A total of 42 knees were investigated, with equal representation in the PS and CR TKA groups. Patients underwent radiostereometric analysis imaging at 0°, 20°, 40°, 60° 80°, and 100° of flexion. Contact position, magnitude of excursion, and condylar separation on each condyle were measured. A Timed-Up-and-Go functional test was also performed by patients, with the total test time being measured. Preoperative and postoperative clinical outcome scores were also collected. RESULTS: There were differences in contact position on both the medial and lateral condyles at multiple angles of flexion (P < .05). There was no difference (P = .89) in medial excursion; however, PS TKA had greater lateral excursion than CR TKA (P < .01). No difference (P > .99) was found in frequency of condylar separation. PS TKA was associated with faster (P = .03) total Timed-Up-and-Go test times. There were no differences in clinical outcome scores between the groups preoperatively or postoperatively. CONCLUSION: We found kinematic and functional differences that favor PS TKA. Our results suggest posterior cruciate ligament insufficiency in CR TKA, indicating that perhaps the cam/post systems in PS TKA better maintain knee kinematics and function long term.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Broberg JS, Ndoja S, MacDonald SJ, et al. Comparison of Contact Kinematics in Posterior-Stabilized and Cruciate-Retaining Total Knee Arthroplasty at Long-Term Follow-Up. J Arthroplasty. 2019. PMID: 31473060. doi:10.1016/j.arth.2019.07.046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。