滑液钙卫蛋白用于慢性假体周围关节感染术前诊断
这项前瞻性观察研究纳入76例疼痛性膝关节置换术后患者,以2018年共识标准为参考,评估滑液钙卫蛋白免疫检测诊断假体周围关节感染(PJI)的可靠性。结果显示钙卫蛋白检测灵敏度100%(95%CI 99.96-100)、特异度95%(95%CI 89.4-100),受试者工作特征曲线下面积0.996(95%CI 94.3-100)。作者认为该检测在膝PJI诊断中具有高灵敏度和特异度,且简便快速、在临床实践中有价值。
要点
- 76例疼痛性膝关节置换术后患者中,28例按2018年共识标准判为感染,44例非感染,4例结论不确定。
- 滑液钙卫蛋白检测出现2例假阳性、无假阴性,灵敏度100%(95%CI 99.96-100),特异度95%(95%CI 89.4-100)。
- 阳性似然比22(95%CI 5.680-85.209),阴性似然比0(95%CI 0-0.292),曲线下面积0.996(95%CI 94.3-100)。
核心结论
- 作者认为滑液钙卫蛋白免疫检测在膝PJI诊断中具有高灵敏度和特异度,且简便快速、在临床实践中有价值。
研究设计与样本
- 前瞻性观察研究,纳入76例疼痛性膝关节置换术后患者,滑液分析包括细胞计数、多形核中性粒细胞百分比、微生物培养、白细胞酯酶试纸、α-防御素快速检测和钙卫蛋白免疫检测。
- 以2018年共识声明PJI标准作为判定感染的参考标准。
主要发现
- 按2018年共识标准,28例判为感染,44例判为非感染,4例结论不确定。
- 滑液钙卫蛋白检测出现2例假阳性结果、无假阴性结果。
- 钙卫蛋白诊断PJI的灵敏度为100%(95%CI 99.96-100),特异度为95%(95%CI 89.4-100)。
- 阳性似然比为22(95%CI 5.680-85.209),阴性似然比为0(95%CI 0-0.292)。
- 受试者工作特征曲线下面积为0.996(95%CI 94.3-100)。
关键数值与推荐
- 2018年共识声明PJI标准作为参考标准:28例感染、44例非感染、4例结论不确定。
- 钙卫蛋白免疫检测灵敏度100%(95%CI 99.96-100)、特异度95%(95%CI 89.4-100)、阳性似然比22(95%CI 5.680-85.209)、阴性似然比0(95%CI 0-0.292)、曲线下面积0.996(95%CI 94.3-100)。
临床怎么用
- 作者认为滑液钙卫蛋白免疫检测在膝PJI诊断中具有高灵敏度和特异度,且简便快速、在临床实践中有价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The diagnosis of periprosthetic joint infection (PJI) represents a challenge in clinical practice and the analysis of synovial fluid is a useful diagnostic tool. Calprotectin is an inflammatory biomarker widely used in the evaluation of chronic inflammatory diseases; however, little is known about its role in PJI. The purpose of this study is to determine the reliability of synovial calprotectin in the diagnosis of PJI. METHODS: Seventy-six patients with painful knee arthroplasty were included in this prospective observational study. Synovial fluid was analyzed for cell count, percentage of polymorphonuclear neutrophils, microbiological culture, leukocyte esterase strip test, alpha-defensin rapid test, and calprotectin immunoassay dosage. The 2018 Consensus Statements criteria for PJI were used as standard reference to define the presence of infection. Sensitivity, specificity, positive and negative likelihood ratio, and receiver-operation characteristic curve were calculated for calprotectin immunoassay test. RESULTS: By 2018 Consensus Statements criteria for PJI, 28 patients were considered infected, 44 patients were considered not infected, and 4 patients were classified as inconclusive. The calprotectin synovial fluid test resulted in 2 false-positive results and no false-negative results. The calprotectin synovial fluid test demonstrated a sensitivity of 100% (95% confidence interval [CI] 99.96-100) and specificity of 95% (95% CI 89.4-100) for the diagnosis of PJI. The positive likelihood ratio was 22 (95% CI 5.680-85.209) and the negative likelihood ratio was 0 (95% CI 0-0.292). The area under the receiver-operation characteristic curve was 0.996 (95% CI 94.3-100). CONCLUSION: The present study suggests that synovial calprotectin immunoassay test has a high sensitivity and specificity in the diagnosis of knee PJI. Moreover, it is easily applied, quick and valuable in clinical practice.
引用
- Salari P, Grassi M, Cinti B, et al. Synovial Fluid Calprotectin for the Preoperative Diagnosis of Chronic Periprosthetic Joint Infection. J Arthroplasty. 2019. PMID: 31542266. doi:10.1016/j.arth.2019.08.052
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。